fig. 31 

- Bifuel “T” inspection

To ensure proper combustion, close 

hermetically the inspection com-

partment.

7.6 Wood compartment cleaning 

(BiFuel)

Clean the grille when its dirty and empty 

the ash collector when it’s full, then put it 

back and tighten the screws 

(fig.  32).

 

fig. 32 

- Wood ash box

7.7 Hopper Cleaning

Saw residues may block the auger. There-

fore, pellet hopper must be emptied and 

cleaned each 10/20 refills, depends on the 

quantity of dust in the pellets. Faulty hop-

per cleaning can void the warranty, with the 

manufacturer declining all related liability.

7.8. Annual service 

Annually contact the local Technical Support

to perform annual service and to check up 

the following components:

•  Door gaskets;

•  Ash box gaskets; 

•  Exchanger gaskets;

•  Tube bundle silicone gaskets;

•  T-inspection gaskets

•  Tube bundle cleaning;

•  Pellet hopper cleaning;

•  Thermostove interspace cleaning; 

• 

Internal flue pipe cleaning; 

•  Air pipeline cleaning;

•  Exhaust fan base cleaning; 

•  Motherboard cleaning; 

•  Hot air tangential fan cleaning

•  Ignition resistance;

•  Burning pot’s integrity;

•  Gearmotor integrity;

•  Expansion vessel;

•  Bushings.

At the end of the maintenance the techni-

tian  must  fill  the  maintenance  document, 

which is required to maintain the guaran-

tee. 

Lack of annual maintenance voids 

the factory boiler/thermostove war-

ranty. The annual maintenance is re-

sponsibility of the customer.

Содержание BiFuel en ELS34

Страница 1: ...USER S MANUAL...

Страница 2: ...tion you have for high quality products To ensure safety please read this manual carefully before installation and follow the instructions herein THE TABLE OF CONTENTS 1 Introduction Pag 3 2 General w...

Страница 3: ...nforming to the specifica tion given above compromises the running of your appliance and can therefore lead to the termination of the guarantee and of the manufacturer s responsibility for the pro duc...

Страница 4: ...ave or pseudo sine wave The appliance must be connected to an electrical system which is equip ped with an earth conductor as laid down in directives 73 23 EEC and 93 98 EEC 2 2 Operating Warnings Pel...

Страница 5: ...emain inside of the room 3 Installation The installation must be carried out by spe cialized personnel under responsibility of the person entrusted with it Ungaro S r l will not be held responsible fo...

Страница 6: ...nnected to a flue pipe or a vertical duct which can discharge the fumes at the highest point of the building conforming to current national regulations Failu re to comply can lead to the termi nation...

Страница 7: ...the vertical section of the chimney inspection insulated outdoor section initial section fig 4 Outdoor Chimney Existing flue fig 5 At the base of the flue is advisable to install a hermitically seale...

Страница 8: ...te from inside and outside fig 8 The air intake must Be in the installation room Be drown outside with a special con nection wood The exit outside must be protected with a metal grate Be un obstructed...

Страница 9: ...water flow external filling heating system flow and return max 1 5 Bar A flow restrictor and filling hose are installed on the DHW kit FL P2 P1 heating system pump P2 three way valve FL flow sensor P...

Страница 10: ...ard manages the temperature set in the tank Contact the Technical Support in your area to activate the configura tion with buffer tank For the buffer tank settings see the chapter Thermostat Settings...

Страница 11: ...ic hot water is being used If it lights up even in heating mode please contact technical support Turn the thermostove on and off with the key 4 Access with the key 3 to program ming functions Use the...

Страница 12: ...be kept within certain limits Please consult local regulations and direc tives 4 4 Remote control Ungaro offers a remote control as standard for easy operation of the thermostove fig 15 Press two keys...

Страница 13: ...e 10 minutes interval Press the key 3 to select the next parameter UT07 g Choose the day of the week with the key 1 With the key 2 enable ON or disable OFF the day of the week for the ignition of the...

Страница 14: ...d ignition On off for days from 1 to 7 UT14 Setting fourth ignition From 00 00 to 23 50 10 minutes lag UT15 Setting fourth ignition From 00 00 to 23 50 10 minutes lag UT16 Setting days of week for fou...

Страница 15: ...the key 2 On the display D1 will ap pear the current water pressure for example 1 0b The recom mended pressure in cold mode is between 0 8 and 1 2 Bar fig 17 fig 17 Pressure In the model Bi Fuel the w...

Страница 16: ...ry for the phase Fire On is Po6 On the display D2 is shown the water temperature The recommended value is 65 C fig 22 fig 22 Set H20 Faulty thermostove and flue pipe maintenance can fault ignition dur...

Страница 17: ...mperature in the thermosto ve falls under 5 C the circulation pump ac tivates to prevent system freezing 6 3 Regulation of pellet and air feeding If the combustion is not regular for exam ple Unburnt...

Страница 18: ...f the fuel the more frequently will intervention be neces sary for cleaning Protect the floor from ash before cleaning the thermostove fig 24 Ash tray To prevent the ash falling during cleaning enable...

Страница 19: ...ce a day when the thermostove is cold fig 27 Exchanger cleaning Regular exchanger cleaning helps to keep high efficiency of the thermo stove 7 4 Ash Box Cleaning Empty the ash box fig 28 when it is fu...

Страница 20: ...ervice Annually contact the local Technical Support to perform annual service and to check up the following components Door gaskets Ash box gaskets Exchanger gaskets Tube bundle silicone gaskets T ins...

Страница 21: ...days When full or dirty Each year Burning Pot Exchanger Ash Box Inspection Compartment Glass Ceramic Fiber Gaskets Gaskets Internal Flue Pipeline Pump Plate Heat Exchanger Main Components Thermostove...

Страница 22: ...r temperatu re if Zoned heating system doesn t have an open zone to dissipate the produ ced heat Circulation pump is blocked Shut off valves are closed If domestic hot water kit is installed and the l...

Страница 23: ...e power cable remove the inspection box and check if there is a foreigh object in the exhaust extraction fan Contact Customer Support ALARM HOT PELL High temperature in the pellet hopper Faulty securi...

Страница 24: ...ermostato Terra flash Trasduttore PRP 300 IMIT 230 V Ventola fumi M M Coclea M Ventola aria P Resistenza accensione Pompa Circuito di Riscaldamento Valvola deviatrice Fase Neutro ALD ALP ALA Bianco Ma...

Страница 25: ...230Vac 50Hz CN9 18 19 Klikson Fluxostat 5 Volt CC 40 GND 5V 5 Volt CC 41 Encoder Encoder 5 Volt CC 42 5V Low tension power fluxostat encoder pressure transducer 5 Volt CC CN7 20 21 S FUMI Exhaust gas...

Страница 26: ...as mass flow rate g s 20 1 fig 34 Serial Number 11 After Sale Service For any information or problem please contact your dealer 11 1 Richiesta d intervento Please read this manual carefully before ask...

Страница 27: ...will give 1 Service Log signed 2 Invoice for the used spare parts for out of warranty interventions UNGARO S r l ricorda che il costrut tore titolare dei diritti previsti dal D lgs 206 2005 e che la s...

Страница 28: ...28 860 920 600 600 80 130 83 113 208 65 115 65 148 Uscita fumi Mandata impianto 3 4 Calda sanitaria 1 2 Fredda sanitaria 1 2 Ritorno impianto 3 4 Entrata Aria Kucina...

Страница 29: ...60 397 346 65 115 65 203 360 190 935 795 60 175 560 795 80 180 Mandata impianto 3 4 Calda sanitaria 1 2 Fredda sanitaria 1 2 Ritorno impianto 3 4 Entrata aria pellet Entrata aria legna Uscita fumi leg...

Страница 30: ...c glass painted fini shes and other external finishes The Customer is in charge of eventual costs re pair transport arising from improper exercise of warranty rights Ungaro S r l is not responsible fo...

Страница 31: ...nd make such data available to a data pro cessor under the terms and conditions set out by the Personal Data Protection Act I acknowledge my right to access the personal data edit it and to withdraw t...

Страница 32: ...0 SAN MANGO D AQUINO CZ Italy Tel 39 0968 926838 Tel 39 0968 96484 Fax 39 0968 926635 www caldoungaro it Under no circumstances shall Ungaro S r l assume liability for imprecise contents or eventual e...

Отзывы: