DG-OHM
UNAOHM Srl Rev. 4.0
32
Instant
UHF
START LOGGER
1
Satellite
VIEW DATA
2
3
To verify measurements made, select VIEW DATA with relative 1,2,3 acquisition. The DATA
LOGGER table will be activated, allowing you to view saved data.
POSITION
CHANNEL
STANDARD
MUX POWER
.
Nr.
CH
DVB
POW
BER
PVBER MER
NM
CELL
0
21 (ITA)
T
62.5
1.4e-4
0.0e-8
25.0
5.4
655
1
22 (ITA)
T
70.2
7.4e-6
0.0e-8
34.5
12.3
655
2
23 (ITA)
T
40.8
3.0e-5
0.0e-8
26.2
8.2
5122
3
24 (ITA)
T
55.3
6.4e-3
0.0e-8
23.1
3.5
0
4
25 (ITA)
T
35.2
----
----
---
--
----
5
26 (ITA)
T
38.6
1.2e-2
4.2e-5
19.3
4636
Dashes in place of measurements will appear when the signal is too critical and has not even
been locked (UNLOCKED or NO CARR).
Single click
to exit from the DATA LOGGER menu.
13.3 SATELLITE DATA LOGGER
The SATELLITE DATA LOGGER has been designed to measure and save data (Power,
BER,PVBER, MER, etc.) relative to the main transponders of the satellite (TPSAT) active in
the instrument.
If you should want to activate the DATA LOGGER for another satellite, proceed as per
paragraph 6.2.1 and start up acquisition as follows:
1. Set the instrument to spectrum analyzer mode (single click
).
2. Press and hold
to open the DATA LOGGER menu.
3. Use
to select SATELLITE and press
.
4. Select one of the 3 possible acquisitions where data will be saved and press
to
start up the measurement cycle relative to the active TPSAT transponders.
DATA LOGGER
Instant
UHF
Satellite
START LOGGER
1
VIEW DATA
2
3