Preparations 

As  an  app dedicatedly designed  for Umbratek Components.  Compatible  with  the ADRA  Series,  FLXI 
Series,  Communication  Modules  and  more.  Umbratek  Assistant  is  compatible  with  a  variety  of 
operating systems, including Windows, MacOS and Linux. 
 
1.

 

Download and install Umbratek Assistant from the official website:   

https://www.umbratek.com/download-center 

2.

 

Select a tool based on the interface type of the actuator (USB-RS485 / USB-CAN / EtherNet-RS485 / 

EtherNet-CAN),  connect  the  actuator  to  the  computer.  DataLink  series  high-speed  modules  are 
available from Umbratek 

 

3.

 

Start Umbratek Assistant 

4.

 

Scan and connect the ADRA actuator to enter the control interface, see 

actuator connection

 for 

details 
5.

 

Use Assistant to test, tune, calibrate, or upgrade the actuator, as described in the following sections. 

Actuator Connection 

1.

 

Select USB or  EtherNet  to connect  the communication device to the computer.  (Figure:  Assistant 

connection interface 1) 
2.

 

Click "Scan", the software will automatically identify the computer port, actuator ID, actuator baud 

rate. When the actuator is identified, it will be displayed in a list. The ID, port, and baud rate of the 
interface will also be automatically set. (Figure: Assistant connection interface 2) 
3.

 

Click Connect to connect the first actuator in the list. 

Note: If you use the encoder battery for the first time or replace/plug the encoder battery for the first 

Содержание ADRA HR Series

Страница 1: ...ADRA ACTUATOR USER MANUAL HR DD Type...

Страница 2: ...power s polarity before wiring CAUTION May cause injury or damage to product Do not operate the product at a temperature exceeding 5 55 C range Do not insert sharp blades nor pins during product opera...

Страница 3: ...__________________________________________15 Rotation Direction ________________________________________________________________________17 Status Led___________________________________________________...

Страница 4: ...Register _________________________________________________________________36 Advanced API Features ___________________________________________________________________36 Debug COM Data ________________...

Страница 5: ...mode Upgrade firmware online or offline Real time graphical curve and data display Data Bus RS485 CAN Up to 32 actuators can be connected on a Bus RS485 up to 12us communication response time up to 11...

Страница 6: ...EN Ver 0 2 0 6 52 2022 Umbratek All Rights Reserved Selection and Specification HR Series Model Rule DD Series Model Rule...

Страница 7: ...ower Voltage Rated DC48V Operating Range DC19 52V Backup Battery 16bit Encoder Battery DC3V 19bit Encoder Battery DC3 6V Standby Current Driver 35mA Encoder Battery 2 9uA Pole Pairs 7 Backlash 0 007 2...

Страница 8: ...le 7 Power Voltage Rated DC48V Operating Range DC19 52V Backup Battery 16bit Encoder Battery DC3V 19bit Encoder Battery DC3 6V Standby Current Driver 35mA Encoder Battery 2 9uA Pole Pairs 10 Backlash...

Страница 9: ...615 Size mm Motor d72 Flange D93 Height H101 Hole 10 Power Voltage Rated DC48V Operating Range DC19 52V Backup Battery 16bit Encoder Battery DC3V 19bit Encoder Battery DC3 6V Standby Current Driver 35...

Страница 10: ...Brake g 2500 2900 2500 2900 2500 2900 2500 2900 2500 2900 Size mm Motor d86 Flange D107 Height H136 Hole 10 Power Voltage Rated DC48V Operating Range DC38 52V Backup Battery 16bit Encoder Battery DC3V...

Страница 11: ...5800 4800 5800 Weight No Brake g 4400 5400 4400 5400 4400 5400 4400 5400 4400 5400 Size mm Motor d113 Flange D138 Height H147 Hole 10 Power Voltage Rated DC48V Operating Range DC38 52V Backup Battery...

Страница 12: ...Pole Pairs 7 10 10 Power Voltage Rated DC48V Operating Range DC38 52V Backup Battery 16bit Encoder Battery DC3V 19bit Encoder Battery DC3 6V Standby Current Driver 35mA Encoder Battery 2 9uA Backlash...

Страница 13: ...d72 D93 H64 d85 H95 d86 D107 H90 d112 H96 3 d113 D138 H91 Hole Diameter mm 7 7 10 10 10 Axial Radial Load kN 1 26 1 26 1 26 1 26 2 47 2 47 2 95 2 95 2 95 2 95 Power Voltage Rated DC48V Range DC19 52V...

Страница 14: ...current overload motor over temperature motor under temperature reverse connection short circuit blocking and other protection functions Warning 1 Do not charge the battery 2 Ensure all the cables are...

Страница 15: ...actuator away from strong magnetic environment iron products and other magnetic materials when installing or using otherwise the actuator may start to vibrate violently 9 Store the actuator and acces...

Страница 16: ...ces and multiple actuators can be used in series The model of the interface seat is BM03B GHS TBT Battery Interfaces Through this interface an external battery can be used to power the multi turn enco...

Страница 17: ...s Description Breathing Normal Standby Always on Normal Enabled Blinks 3Hz Fault Error check error code Blinks 10Hz Normal Boot mode Extended I O The interfaces are IO1 IO2 RX TX and GND from left to...

Страница 18: ...tor is disabled TX TTL output mode debugging information output serial port For details see debugging COM Information 3 Debug Mode Not released yet need to update the firmware IO1 TTL output mode test...

Страница 19: ...Umbratek 3 Start Umbratek Assistant 4 Scan and connect the ADRA actuator to enter the control interface see actuator connection for details 5 Use Assistant to test tune calibrate or upgrade the actuat...

Страница 20: ...l be reminded that the multi turn encoder is abnormal when connecting to Assistant You only need to calibrate the encoder as prompted by the software and power on the actuator again after calibration...

Страница 21: ...actuator voltage current temperature torque speed position and reduction ratio The data will be refreshed at a frequency of 2Hz 2 The oscilloscope button is in the upper right corner of the status bar...

Страница 22: ...and the acceleration is proportional to the parameter acceleration coefficient Max speed The factory default value is the maximum speed of the actuator You need to adjust this parameter based on your...

Страница 23: ...t and stop The acceleration and deceleration of actuator motion will carry out speed planning similar to S curve and this coefficient adjusts the magnitude of acceleration and deceleration of S curve...

Страница 24: ...the planned position is greater than this value the actuator will report an error Smooth Cycle Position command smoothing cycle If set to N after a new target position is set each position control pe...

Страница 25: ...the acceleration is proportional to the parameter acceleration coefficient Assistant Quick Test Select speed mode Enable the current mode Enable actuator Input target velocity Set the target velocity...

Страница 26: ...cient Acceleration coefficient of speed loop The smaller the value the smaller the acceleration the gentler the start and stop The acceleration and deceleration of actuator motion will carry out speed...

Страница 27: ...tivation button needs to be enabled for setting operation Smooth Cycle Speed command smoothing cycle If set to N after a new target speed is set each speed control period only takes effect for 1 N rel...

Страница 28: ...an error is reported Assistant Quick Test Select torque mode Enable the current mode Enable actuator Input target torque Set the target torque Assistant Torque Mode Steps for API Usage 1 Set motion mo...

Страница 29: ...after being set Please pay attention to whether the parameters are reasonable If the parameters are inappropriate the actuator will vibrate violently or even break 4 Click save after parameter setting...

Страница 30: ...erface Parameter Description Min Position Limit Position minimum value This applies to position mode but not to speed and torque mode Max Position Limit Position maximum value This applies to position...

Страница 31: ...rror Maximum temperature error If the temperature is higher than this value the actuator reports an error Min Voltage Error Minimum voltage error If the voltage is lower than this the actuator will re...

Страница 32: ...LED will blink quickly After about 3 seconds the LED will blink slowly indicating that the upgrade is in progress After the upgrade is complete the indicator turns to breathing If the indicator still...

Страница 33: ...returned to factory calibration The encoder of the actuator has been calibrated and strictly tested before delivery Normally users do not need to perform encoder calibration However if the actuator is...

Страница 34: ...1 Click Zero calibration and the calibration time is about 5 seconds according to the software prompt 2 After the software prompts completion of calibration please power on again before use 3 Do not p...

Страница 35: ...ght corner otherwise the parameters will be lost after the shutdown The factory default reduction ratio is 1 1 Reset Error Code On the Settings interface Actuator errors can be reset without restart F...

Страница 36: ...uators support standard RS485 and CAN electrical interfaces The RS485 port uses the UTRC protocol and the CAN port uses the UTCC protocol Document UTRC https umbratek com wiki en adra utrc_communicati...

Страница 37: ...dress is 0x60 API function set_cpos_target uint8_t sid uint8_t eid float pos Broadcast mode a packet sets the target position of multiple actuators sequential ids For example if the target positions o...

Страница 38: ...e commands that has been received Example of setting the target position and feedforward torque of actuators 1 through 6 AdraApiSerial adra new AdraApiSerial dev ttyUSB0 921600 adra into_motion_mode_p...

Страница 39: ...time When reading actuator data in broadcast mode you must send a broadcast read command within a specified period If the communication interruption period exceeds the specified period the actuator re...

Страница 40: ...bratek All Rights Reserved 4 Debug Mode 54 Set the debug mode to 54 and output the data of torque loop ADRC control algorithm 2 5 Debug Mode 63 Set the debug mode to 63 and output the data of torque l...

Страница 41: ...les service 11 electrical angle error Use the assistant to calibrate encoder 12 Encoder linear error Use the assistant to calibrate encoder 13 Multi turn calibrate error Use the assistant to calibrate...

Страница 42: ...ad is consistent Control parameter matching 33 Current power out of range 1 Check whether the load and speed are within the normal range 2 Check whether the power supply voltage is stable 3 Check whet...

Страница 43: ...tuator which will detect the voltage of the power in real time When the voltage of the power supply is higher than the rated voltage the part of excessive energy will be released through the brake res...

Страница 44: ...EN Ver 0 2 0 44 52 2022 Umbratek All Rights Reserved Mechanical Mounting The 3D model of this product can be downloaded from the official website https www umbratek com download center...

Страница 45: ...EN Ver 0 2 0 45 52 2022 Umbratek All Rights Reserved...

Страница 46: ...EN Ver 0 2 0 46 52 2022 Umbratek All Rights Reserved...

Страница 47: ...EN Ver 0 2 0 47 52 2022 Umbratek All Rights Reserved...

Страница 48: ...EN Ver 0 2 0 48 52 2022 Umbratek All Rights Reserved...

Страница 49: ...EN Ver 0 2 0 49 52 2022 Umbratek All Rights Reserved...

Страница 50: ...EN Ver 0 2 0 50 52 2022 Umbratek All Rights Reserved...

Страница 51: ...ponsible or liable for any such statements Buyer acknowledges and agrees that it is solely responsible for compliance with all legal regulatory and safety related requirements concerning its products...

Страница 52: ...EN Ver 0 2 0 52 52 2022 Umbratek All Rights Reserved Copyright 2022 Umbratek All Rights Reserved...

Отзывы: