Ulvac DOP-181S Series Скачать руководство пользователя страница 29

17

 

7.  In Conclusion 

Please contact the manufacturer’s sales division if you have any questions. 

 

 

Warranty 

 
(1)  The  warranty  for  this  pump  extends  for  a  period  of  one  year  from  the  date  of 

shipment. 

(2)  Any  malfunctions  or  defects  which  occur  under  normal  usage  conditions  during  the 

warranty period will be repaired free of charge. 

Note,  the  warranty  stated  here  is  an  individual  warranty  covering  the  pump.  In 

addition, the scope of the warranty coverage concerning repairs is limited to the repair 

and/or replacement of parts. 

Normal usage conditions refer to the following: 

a) Ambient temperature and humidity during operation: Ambient temperature range 

of product specification, below 85% RH 

b) Operation in accordance with the user manual 

(3) Repair fees will incur during the warranty period for the following cases: 

a) Malfunctions due to a natural disaster or fire. 

b)  Malfunctions  caused  by  special  atmospheric  conditions,  such  as  salt  damage, 

inflammable gas, corrosive gas, radiation or pollution. 

c)  Malfunctions  caused  by  usage  conditions  that  differ  from  those  stated  in  the 

user manual (performance specifications, maintenance and inspection, etc.). 

d) Malfunctions caused by modifications or repairs carried out by a party other than 

the manufacturer, or by a service company not approved by the manufacturer. 

e) Malfunctions caused by noise (electric disturbance). 

f) Malfunctions that occur when not using a rated power supply. 

g) Malfunctions that occur when there is an abnormal rise in internal pressure due 

to the pump exhaust outlet being blocked during operation, etc. 

h)Malfunctions that occur, when the pump is damaged as a result of being dropped 

or falling, etc. 

i) Malfunctions which are determined by the manufacturer’s technical personnel to 

be  caused  by  conditions  that  do  not  comply  with  the  usage  conditions  for  this 

vacuum pump. 

j) Malfunctions due to the replacement of consumables.         

(4) Disclaimer 

a)  We  shall  not  be  liable  for  any  malfunctions  of  our  products  caused  by  the 

customer, regardless if the malfunction does not fall within the warranty period, 
nor shall we be liable for any loss of opportunity for the customer’s clients or for 
compensation  for  any  damages  to  other  products,  labor  costs,  production  loss, 

transportation expenses and other related work.   

b)  We  shall  not  be  liable  for  any  claims  and  patent  infringements,  including 

secondary damages, filed a claim by a third party against the customer.   

 

Содержание DOP-181S Series

Страница 1: ...P 181SC DOP 181SD DOP 181SE Request to Users Please read this manual thoroughly to ensure safe and effective use of the equipment Keep this manual in a safe place Due to periodic improvements in perfo...

Страница 2: ...ressors and vacuum pumps Safety requirements Part2 Vacuum pumps IEC EN 61010 1 2010 A1 2019 Safety requirement for electrical equipment for measurement control and laboratory use Part1 General require...

Страница 3: ...is in conformity with the following standards BS EN 1012 2 1996 A1 2009 Compressors and vacuum pumps Safety requirements Part2 Vacuum pumps BS IEC EN 61010 1 2010 A1 2019 Safety requirement for elect...

Страница 4: ...Environmental Conditions for Installation Storage and Operation 4 3 3 Location 4 3 4 Operational Checks Following Installation 5 3 5 Electric connection 5 3 6 Fluctuations in the power voltage and fr...

Страница 5: ...Tables Fig 2 1 DOP 181SA 181SB 2 Fig 2 2 DOP 181SC 181SD 3 Fig 2 3 DOP 181SE 3 Fig 3 1 Change region of the voltage and frequency 6 Fig 3 2 Example of Piping Used When Evacuating a Vessel 7 Fig 6 1 E...

Страница 6: ...nt correctly Read the section on Safe Use particularly closely Keep This Manual in a Safe Place After reading this manual be sure to keep it in a safe place which is readily accessible to others needi...

Страница 7: ...oblems with the pump 1 When take out a pump from a packing box Do not grip the pipe of the upper of the pump In addition please do not do an act bending by pushing A pipe is damaged and pump performan...

Страница 8: ...the equipment may result in death or serious injury to the operator Incorrect handling of the equipment may result in light or medium injuries to the operator or damage to the equipment Incorrect han...

Страница 9: ...s may decline an overhaul Please pay attention enough 4 To reduce the risk of fire and explosion damage enclose the pump by non flammable cover Power Supply 5 Always switch off the main power supply a...

Страница 10: ...or objects into the motor inlet may result in electric shock injury or fire 18 Operating the pump with the discharge outlet blocked or with a device which prevents passage of gas to the discharge outl...

Страница 11: ...When the thermal protector operates the pump will become extremely hot Please do not touch the pump Touching the pump in that condition will cause burn injury Turning off the main power supply of the...

Страница 12: ...istics 5 This pump is only for vacuum pumping Use at near atmospheric pressures for long periods of time may result in a malfunction Operation 6 Use the pump at an ambient temperature of Ambient tempe...

Страница 13: ...mpt to evacuate gases containing particles dust water or corrosive gases 5 Do not operate the pump for long periods at near atmospheric pressure 1 2 Specifications Table 1 1 Product Specifications DOP...

Страница 14: ...rcuit automatically to prevent burn out if the motor temperature rises due to overloading or there is a pump fault which prevents rotation 2 Always fit other protective devices eg earth leakage breake...

Страница 15: ...Fig 2 2 DOP 181SC 181SD Fig 2 3 DOP 181SE...

Страница 16: ...ve gas f Not subject to direct sunlight g No danger of fire h Do not exceed the maximum ambient temperature of the temperature range of product specification at the time of pump installation refer to...

Страница 17: ...r higher one earth wire included 3 Phase motor 4 Core cable Size of the wire lead 1 0m or larger 300V or more 10A or more 80 or higher one earth wire included The temperature rating of the power cord...

Страница 18: ...lting in the grade which shortens a life remarkably and the characteristic a temperature rise etc do not apply correspondingly in the state of rating Moreover main rating shows rated torque N m 3 7 Th...

Страница 19: ...ge pressure 4 In case of selecting the inlet pipe and exhaust pipe that are not from our products please select the exhaust pipe that has same or larger inner diameter length with the inlet pipe 5 Ple...

Страница 20: ...5 6 and 9 on p 06 Immediately switch off the main power and contact to the manufacturer when thermal protector is activated 4 3 Starting in Cold Weather The bearing grease and cup packing may harden u...

Страница 21: ...value achieved with dry air 5 3 Power Requirements The power required to operate the pump is the total of the work required to overcome the rotational resistance of the pump mechanical work and the wo...

Страница 22: ...SUS 6000 Hr O ring 4 EPDM 6000 Hr Head gasket 2 EPDM 6000 Hr Bearing 1 set 15000 Hr Power supply cord 1 set At any time Life of these components tends to be extended when the requirements in 4 1 Cauti...

Страница 23: ...ediately after operation After stopping the pump leave it for 30 minutes or more and begin replacing consumables and cleaning only after checking that it has cooled sufficiently 2 To prevent ingestion...

Страница 24: ...pump Refer to the exploded view Fig 6 1 Remove all cap screws M6 95L 8 No 1 that fasten the pump head No 2 to the Casing Remove the pump heads assembly No 5 Head gasket No 6 is attached inside the pum...

Страница 25: ...e a new O rings Clean a connecting pipe s O ring groove installation hole before replace The head gasket gets pinched when extruding from the gasket groove Ensure that head gasket are fully assembled...

Страница 26: ...rts Photo7 Cylinder Gasket Photo8 Cup packing Connecting rod 6 4 7 Reassembling the pump Refer to the exploded view Fig 6 1 clause 6 4 2 Disassembling the pump Place the cup packing cup packing retain...

Страница 27: ...Fig 6 1 Exploded view OUTLET INLET...

Страница 28: ...2 Measure the pressure correctly 5 1 3 Vacuum gauge is unsuitable 3 Measure with a calibrated vacuum gauge suitable for the pressure range 5 1 4 The inlet piping is too small in diameter or too long...

Страница 29: ...ons maintenance and inspection etc d Malfunctions caused by modifications or repairs carried out by a party other than the manufacturer or by a service company not approved by the manufacturer e Malfu...

Страница 30: ...Industrial Safety and Health Law designates particular substances as the materials to be notified 2 Usage Status Operation Method Approx hours per day years and months Continuous Operation Intermitte...

Страница 31: ...6 6397 2286 ULVAC KIKO Inc https ulvac kiko com en Please contact us for products Service Base or other Inquiries from here ULVAC Inc Components Division 2500 Hagisono Chigasaki Kanagawa 253 8543 Japa...

Отзывы: