Warranty 
 

(1)  The warranty for this pump extends for a period of one year from the date of

 

shipment

.

 

(2)  Any  malfunctions  or  defects  which  occur  under  normal  usage  conditions  during  the 

warranty period will be repaired free of charge. 

   

Note, the warranty stated here is an individual warranty covering the pump. In addition, 

the scope of the warranty coverage concerning repairs is limited to the repair and/or 

replacement of parts. 

Normal usage conditions refer to the following: 

a)  Ambient temperature and humidity during operation: 7 - 40°C, below 85% RH 

b)  Operation in accordance with the user manual 

(3)  Repair fees will incur during the warranty period for the following cases: 

a)  Malfunctions due to a natural disaster or fire. 

b)  Malfunctions  caused  by  special  atmospheric  conditions,  such  as  salt  damage, 

inflammable gas, corrosive gas, radiation or pollution. 

c)  Malfunctions  caused  by  usage  conditions  that  differ  from  those  stated  in  the  user 

manual (performance specifications, maintenance and inspection, etc.). 

d)  Malfunctions caused by modifications or repairs carried out by a party other than the 

manufacturer, or by a service company not approved by the manufacturer. 

e)  Malfunctions caused by noise (electric disturbance). 

f)  Malfunctions that occur when not using a rated power supply. 

g)  Malfunctions that occur when there is an abnormal rise in internal pressure due to the 

pump exhaust outlet being blocked during operation, etc. 

h)  Malfunctions that occur, when the pump is damaged as a result of being dropped or 

falling, etc. 

i) 

Malfunctions  which  are  determined  by  the  manufacturer’s  technical  personnel  to  be 

caused  by  conditions  that  do  not  comply  with  the  usage  conditions  for  this  vacuum 

pump. 

j)  Malfunctions due to the replacement of consumables. 

(4)    Disclaimer 

         

a)    We shall not be liable for any malfunctions of our products caused by the customer, 

regardless if the malfunction does not fall within the warranty period, nor shall we be 

liable for any loss of opportunity for the customer’s clients or for compensation for any 

damages to other products, labor costs, production loss, transportation expenses and 

other related work. 

        b)    We shall not be liable for any claims and patent infringements, including secondary 

damages, filed a claim by a third party against the customer.

 

 

Содержание DAU-100

Страница 1: ...Please read this manual thoroughly to ensure safe and effective use of the equipment Keep this manual in a safe place Due to periodic improvements in performance the equipment described in this manual...

Страница 2: ...3 5 Piping 4 3 6 Storage 4 4 Cautions for Operation 5 4 1 Cautions for Operation 5 4 2 Operation of the Thermal Protection Relay 6 4 3 Starting in Cold Weather 6 5 Pump Performance 6 5 1 Pressure Ach...

Страница 3: ...0 Dimensions 2 Fig 3 1 Example of Piping Used When Evacuating a Vessel 4 Table 1 1 Product Specifications 50 60 Hz 1 Table 6 1 Consumables List 8 Table 6 2 Locations for Maintenance and Inspection 8 T...

Страница 4: ...pment correctly Read the section on Safe Use particularly closely Keep This Manual in a Safe Place After reading this manual be sure to keep it in a safe place which is readily accessible to others ne...

Страница 5: ...d Standard accessories User s manual x 1 Inlet and outlet caps fitted to inlet and outlet x 2 Power plug adapter attached to power cord x 1 3 Is the pump damaged in any way 4 Are any external screws o...

Страница 6: ...followed Safety icons The meanings of the safety icons are as follows Incorrect handling of the equipment is very likely to result in death or serious injury to the operator Incorrect handling of the...

Страница 7: ...lectric shock or the pump suddenly starting and causing injury Ensure that the relevant wiring is in accordance with technical standards for electrical equipment and wiring regulations Incorrect wirin...

Страница 8: ...a pipe from the discharge outlet to the outside of the building The fine clearances used in this pump require that the following conditions be satisfied during storage installation and operation 1 Amb...

Страница 9: ...orrosion proof Use it only with clean air at normal temperature or gases of equivalent characteristics 4 Do not attempt to discharge gases containing particles dust water or corrosive gases 5 Do not o...

Страница 10: ...ll interfere with normal operation of the overload protection relay and may result in motor burnout or fire When the overload protection relay operates the pump will be extremely hot Touching the pump...

Страница 11: ...remove the power cord from the outlet before joining electrical wiring Do not undertake such work on live wires under any circumstances Always ensure that the pump is correctly earthed A dedicated ear...

Страница 12: ...details 3 4 Wiring 1 Remove the caps from the inlet and outlet pipes before using the pump 2 The wiring is already connected to the pump Check that the pump switch is set to O and connect the power su...

Страница 13: ...is pump is not designed to be explosion proof Ensure that the vicinity of the motor and pump is completely free of inflammable materials e g inflammable solvents Use in the presence of such materials...

Страница 14: ...t pressure using a Baraton vacuum gauge Absolute Pressure Transducer 626A Note that the indicator values for pressure may differ between types of vacuum gauges The pressure achieved in practice is hig...

Страница 15: ...er than the manufacturer s standard options 1 Replacing diaphragms 2 Replacing valves 3 Replacing non return valves 4 Replacing O rings 5 Replacing head gaskets Always remove the power cord before rep...

Страница 16: ...r a component varies with the conditions of use Bearings are replaced by the manufacturer s service division Replacement Guide Diaphragms Replace if cracked worn hard or deformed Valves Replace if def...

Страница 17: ...18 N m torque 6 Torque driver Cross head No 2 set to 5Nm torque 7 Spanners For 14 26 and 29mm nuts or equivalent adjustable spanner 8 Thread lock Loctite 242 9 Vacuum grease 10 Paper towels ethyl alco...

Страница 18: ...terminal on the red wire connected to the cooling fan Remove the rear panel 8 Remove the four hexagon socket head cap screws M6 x 22L in the pump head and remove the pump head 9 Remove the four hexago...

Страница 19: ...g and fix in place in the same position as the connecting rod Tighten the four hexagon socket head cap screws M6 x 22L equally to 16Nm with a torque wrench 15 Place the pump head gasket and pump head...

Страница 20: ...Remove the two hexagon socket head cap screws M5 x 16L in each valve retainer inlet and outlet fit a hexagon socket head cap screw in the center of the inlet and outlet valve retainers pull the valve...

Страница 21: ...at the valves are not misaligned and that they are not pinched in the valve retainer 3 Apply a small amount of Loctite 242 or equivalent to the two hexagon socket head cap screws M5 x 16L in each valv...

Страница 22: ...turn valve with a paper towel soaked in ethyl alcohol and place in the non return valve casing 6 Turn the side of the valve seat with the depression downwards Note Tap the valve seat gently and check...

Страница 23: ...er disassembly clean the various components with a paper towel soaked in ethyl alcohol 4 Apply a uniformly thin covering of vacuum grease to the new O ring and replace the old O ring 5 Assemble in the...

Страница 24: ...in the reverse order to disassembly 5 Replacing head gaskets simultaneous replacement of head gaskets and non return valves is recommended Use tools No 1 3 5 7 9 and 10 1 Remove up to the head gasket...

Страница 25: ...Pressure measurement is incorrect 2 Measure the pressure correctly 5 1 3 Vacuum gauge is unsuitable 3 Measure with a calibrated vacuum gauge suitable for the pressure range 5 1 4 The inlet piping is t...

Страница 26: ...nspection etc d Malfunctions caused by modifications or repairs carried out by a party other than the manufacturer or by a service company not approved by the manufacturer e Malfunctions caused by noi...

Страница 27: ...Industrial Safety and Health Law designates particular substances as the materials to be notified 2 Usage Status Operation Method Approx hours per day years and months Continuous Operation Intermitte...

Страница 28: ...6 6397 2286 ULVAC KIKO Inc https ulvac kiko com en Please contact us for products Service Base or other Inquiries from here ULVAC Inc Components Division 2500 Hagisono Chigasaki Kanagawa 253 8543 Japa...

Отзывы: