06
Installation
(1) The fine clearances used in this pump require that the following conditions be satisfied
during storage, installation, and operation.
1.
Ambient temperature of 7~40°C and maximum relative humidity of 85% during
operation.
2. Equal to or less than meters above the sea level 1000m storage and operation.
3.
Other conditions for storage and operation.
a) Level floor of sufficient strength.
b) No condensation
c)
Dust-free environment
d) Well ventilated
e) Environment free of corrosive or explosive gas.
f)
Not subject to direct sunlight.
g) No danger of fire.
h) Maximum ambient temperature of 40°C during assembly of pump.
i) Free of soot and oil.
j) Free of splashing or flooding.
k) Keep it indoor ventilated.
l) When installing the pump, avoid mounting a vacuum pump directly on the base.
Employ anti-vibration rubber between the base and the vacuum pump.
(2) To prevent back injury, always use both hands to lift pumps.
(3) Microscopic particles resulting from wear of components are discharged from the outlet and
contaminate the room. If necessary, connect a pipe from the discharge outlet to the outside
of the building.
Operation
(4) Do not use in applications involving organ transplants, or contact with body fluids or living
tissue.
(5) Touching rotating components (e.g. motor, main shaft, axial joints) while the pump is in
operation may result in injury.
(6) The overload protector operates when the pump becomes excessively hot. Touching it in
this condition may result in burns.
(7) Touching the motor while the pump is in operation or while it is still hot immediately after
having been switched off may result in burns.
(8) Do not insert fingers or objects into, or peer into, the inlet or outlet during operation.
(9)
Ensure that the customer installs a trap if steam is generated. Ensure that condensate does
not enter the vacuum pump. A malfunction may result if condensate enters the pump.
Maintenance and Repair
(10) Dispose in accordance with legislation for disposal and cleaning of waste products, handle
as industrial waste, and do not incinerate.
(11) If the pump ceases operation, turn power OFF immediately to prevent accidents, remove
the power cord from the terminal, and contact your dealer or the manufacturer for
inspection and repair.
(12) Leave the pump for at least 30 minutes until it has cooled, and begin operation again.
Touching the pump immediately after it has stopped may result in burns.
(13) As the pump is not protected against entry of water, it is not guaranteed against splashing
or flooding.
!
Caution