background image

 

U-Series Operating Manual 

13 

C6000610 

Ultrasonic cleaning detergents 

Detergents are a vital component in the ultrasonic cleaning process, aiding in 
the removal and loosening of debris from the surfaces of items placed in the tank 
while also intensifying the power of the ultrasonic activity.  
Ultrawave offers a range of specially formulated ultrasonic detergents for use in 
applications including medical and heavier industrial cleaning requirements. 

Sonozyme: 

A poly-enzymatic detergent for cleaning surgical instruments.  

Ultraclean M2

: A general purpose detergent for plastics, glass and metals 

(except aluminium and other soft metals) 

Ultraclean SA

: A general purpose cleaning detergent for aluminium and other 

soft metals. 

Ultraclean CS

: A carbon and heavy contaminant remover.  

(except aluminium and other soft metals)  

Ultraclean CBX

: A heavy oil and carbon remover for non-ferrous metals 

(except aluminium and other soft metals). 

Ultraclean SPX

: An alkaline detergent for heavy carbon and tough grease.  

(except aluminium and other soft metals) 

Ultraclean PH

: A rust removal detergent and brightening agent for non-

ferrous metals (except aluminium and other soft metals). 

Ultraclean RI

: Rust inhibitor for corrosion prevention of ferrous metals.  

 

Dosing Matrix (ml of detergent per tank) 

 

 

Detergent dose (ml) 

 

Tank capacity (L) 

2% 

5% 

U100 

1.5 

30 

75 

U100H 

1.5 

30 

75 

U300 

2.5 

50 

125 

U300H 

2.5 

50 

125 

U500H 

4.5 

90 

225 

U1300H 

12.5 

250 

625 

U2500H 

25 

500 

1250 

Each  of  these  detergents  is  available  from  Ultrawave.  The  required  detergent 
dose  may  vary  depending  on  the  component  being  cleaned  and  the  level  of 
contamination. Ultrawave recommends a dosage of between 2 and 5% for all 
detergents other than Sonozyme

, which is recommended at 0.5% by volume

Содержание U Series

Страница 1: ...C6000910 01 issued October 2021 U Series Operator Instruction Manual...

Страница 2: ...Panel Instructions U100 U300 9 Manual II Control Panel Instructions U100H 10 Manual III Control Panel Instructions U300H U500H U1300H U2500H 11 Technical Information 12 Ultrasonic cleaning detergents...

Страница 3: ...e rated at up to 850W maximum The detachable mains lead is rated at 250V 6A NEVER FIT A LEAD WITH A LOWER RATING The mains plug is fitted with a 5A fuse NEVER FIT A FUSE OF A HIGHER RATING The detacha...

Страница 4: ...l before operating the equipment Safety may be impaired if they are not followed Ultrawave will not be responsible for damage or injury caused by incorrect use of the equipment The user should apply t...

Страница 5: ...Indicates a potentially hazardous situation which may result in minor or moderate injury It may also be used to alert against unsafe practices Equipment Alert Indicates a potentially hazardous situati...

Страница 6: ...included with the U Series ultrasonic baths 1 x U Series ultrasonic bath 1 x basket 1 x lid 1 x Ultraclean detergent sample 1 x Operator Instruction manual How to install Connect the mains lead into...

Страница 7: ...detergent sample 1 x Operator Instruction manual How to install Locate the bath close to a drain or sink to allow easy drainage of the tank Connect the mains lead into a suitable mains socket Screw th...

Страница 8: ...ired temperature and pressing the HEAT button Turn on the ultrasonics for approximately 5 10 minutes to degas the cleaning liquid See page 10 for more details on degassing The bath is now ready to use...

Страница 9: ...The SONICS button and the SONICS light will glow Ultrasonic activity will then commence in the liquid inside the tank and the Timer dial will be heard ticking At the end of the timed period the Timer...

Страница 10: ...the SONICS light will go out and the ultrasonic activity in the liquid will stop To stop the ultrasonic activity at any time turn the Timer dial to 0 while in operation To operate the heater Press the...

Страница 11: ...rasonic activity at any time press the SONICS button while in operation To operate the heater Turn the HEATER dial to the desired temperature and press the HEAT button The HEAT button and the HEAT lig...

Страница 12: ...eat Heating the liquid in the bath will aid the cleaning process Normally a temperature of between 30 to 60 C is sufficient to accelerate the process You will see from the graph below that optimum cle...

Страница 13: ...aminant remover except aluminium and other soft metals Ultraclean CBX A heavy oil and carbon remover for non ferrous metals except aluminium and other soft metals Ultraclean SPX An alkaline detergent...

Страница 14: ...ls Mains supply 230V 50Hz Pollution degree 2 Installation category II Note Mains supply voltage fluctuations are not to exceed 10 of the nominal supply voltage Ultrasonic frequency 32 to 38kHz Heater...

Страница 15: ...g Ultrawave has a dedicated After Sales team who are able to resolve any problems that occur with your bath However on many occasions it is possible that the problem can be rectified by the operator T...

Страница 16: ...s policy Returning equipment to Ultrawave All equipment being returned to Ultrawave for service repair or other reason MUST BE FULLY DECONTAMINATED prior to return and include a copy of the certificat...

Страница 17: ...n observance of maintenance service or connection instructions damage caused by the use of toxic flammable acidic caustic or corrosive chemicals or fluids not recommended by Ultrawave The user should...

Страница 18: ...h information and training is now 80 decibels There is also an exposure limit value of 87 decibels taking account of any reduction in exposure provided by hearing protection above which workers must n...

Страница 19: ......

Страница 20: ...C6000910 01 issued October 2021 Ultrawave Ltd Eastgate Business Park Wentloog Avenue Cardiff CF3 2EY UK www ultrawave co uk Tel 44 0 29 2083 7337 GB...

Отзывы: