background image

1. Select the desired DMX address on the digital display for the hazer.

Note:

 The hazer occupies two sequential DMX addresses. The maximum DMX address of 511 must    

           be set if using the last two DMX addresses in the chain.  

Note:

 The display goes to sleep when not in use. Touching any key once wakens it. 

The selected address is the Haze rate and the selected a 1 is the fan speed. Control is from 
0 - 100% with “0‘’ turning the haze output off and reducing the fan to its minimum default speed. The Versa     
Fan Power Port output will also be adjusted.

2.  Insert the DMX line into “DMX in”connector. 

3. Plug the unit into a suitable power source. Turn the main power switch on and it will illuminate if 
    power is present. The valid DMX light will be solid when DMX signal is present. The heat up time is 
    approximately 8 minutes before haze can be produced. The Green LED on the back of the unit 
    indicates heating when flashing and ready when solid. A three-flash pattern with the fan turning ON 
    to full speed, indicates an over temperature error.
    The fan has a minimum setting and should always run when the power is applied. The fan speed can 
    only be changed when haze is being produced.

4. 15 Minutes prior to shutting down your Radiance Hazer, adjust your output setting to “0” Doing this 
    will consume any haze fluid that is still in your distribution feed tubes and processing block. Failure to 
    do so will result in raw fluid being discharged from your output nozzle when you operate it next start-
    up and will help reduce (not stop) the residue buildup 

Note: DMX Operation overrides  hand held held remote operation controls.

DMX Operation

RDM features will allow remote identify by flashing the DMX display, DMX address changing and machine 
temperature monitoring. As well the machine’s group and manufacturer identification data are available. 

RDM Functions

www.ultratecfx.com

4

DMX Light

DMX IN

DMX Address 

Versa Fan 
Power Port

Содержание CLF2460

Страница 1: ...Radiance Hazer v 102020 Operators Manual ...

Страница 2: ...tions 2 Technical Drawings 2 Radiance Setup 3 Operating Procedure 3 Stand Alone Operation 3 DMX Operation 4 RDM Functions 4 Operation with Hand Remote 5 Maintenance Procedure 6 Troubleshooting 6 Recommended Fluid 6 Warranty 7 Contact Information 8 Table of Contents ...

Страница 3: ...uses only Ultratec Special Effects Luminous 7 Haze Fluid which is a proven fluid that offers the best in low consumption with superior visual hang time It can accommodate both the 2L or 4L sizes of the Ultratec fluid containers 1 Ensure that any operation of the machine is supervised by suitably trained and authorized personnel 2 Do not modify the machine or use a machine which has been damaged in any...

Страница 4: ...ater Base Haze Fluid Consumption settings from 27 380 cc hour Even lower output is achieved by using the Interval Timer Features 5 Pin USITT DMX 512 RDM Protocol Truss Mount Angle Floor Stand Power Cord 6 Detachable IEC Cord Heat up 8 Minutes Run Time Continuous Approvals 120V Full certification by T U V CE Certified 220 VAC CSA UL certified by QPS for 240 VAC Technical Drawings Technical Specificatio...

Страница 5: ...will consume any haze fluid that is still in your distribution feed tubes and processing block Failure to do so will result in raw fluid being discharged from your output nozzle when you operate it next start up and will help reduce not stop the residue buildup Note Stand Alone Operation overrides DMX and held held remote operation controls Radiance Setup Operating Procedure After power up the rear ...

Страница 6: ...LED on the back of the unit indicates heating when flashing and ready when solid A three flash pattern with the fan turning ON to full speed indicates an over temperature error The fan has a minimum setting and should always run when the power is applied The fan speed can only be changed when haze is being produced 4 15 Minutes prior to shutting down your Radiance Hazer adjust your output setting to...

Страница 7: ...utput increases as the variflow knob turns clockwise 6 The assist fan is always on low Fan speed can be increased by rotating the fan knob clockwise The fan only speeds up during haze output The Versa Fan Power Port output will also be adjusted 5 The interval knob is used to provide cycled output It must be set fully counterclockwise off when continuous haze output is required The hazer will produce...

Страница 8: ...Contact Ultratec Special Effects for more help with this UNIT DOES NOT PRODUCE HAZE 1 Check that fluid pick up hose is sufficiently submerged into fluid in jug 2 Ensure fluid pickup line is fully primed with fluid 3 Ensure that green heater status LED is ON solid indicating that unit is fully heated 4 If using Standalone Mode ensure DMX address is set to 600 and that the 10 s column is set between 1 8 5 ...

Страница 9: ...f the repair Ultratec Special Effects will return the unit via the most economical means available Should you require the item express returned the user dealer is responsible for indicating this request and for any difference in freight cost Warranty will be voided and customer will lose all rights guaranteed by the warranty if any of the following are observed occur If any non Ultratec Special Ef...

Страница 10: ... Effects GmbH Dieselstrasse 30 40 60314 Frankfurt am Main Germany Direct 49 69 87 000 1850 Fax 49 69 87 000 1899 Canadian Shipping Address For All Canadian Repairs Ultratec Special Effects 1960 Blue Heron Drive London Ontario N6H 5L9 USA Shipping Address For All USA Repairs Ultratec Special Effects 640 Gadson Street Groveland Florida 34736 Contact Us www ultratecfx com 8 ...

Отзывы: