background image

   Warning!!

WARNING!!

1. Do not touch, place hands or expose skin within 20”(50cm) of the discharge nozzle.
2. Do not remove the outer case.
3. Persons suffering from asthma or allergenic sensitivity may experience irritation, discomfort or 
    allergic symptoms when exposed to fog effects.
4. Ensure that this unit is grounded at all times. Failure to do so may result in serious injury.
5. Use Ultratec Special Effects Luminous 7 Water Base Haze Fluid 

ONLY

.  A Luminous 7 SDS is 

    available at www.ultratecfx.com

Ultratec Special Effects Radiance Haze Machine is a major advancement in Water Based Haze Technology. 
Once again, Ultratec Special Effects is setting new standards that all other haze machines will be measured 
against. 

Features include:  

Digital DMX address display. 

 

 

 

Built-In DMX that controls both the Haze Output and the Internal Fan. 

This combination offers excellent haze control and even dispersion. The Radiance can also be operated by an 
optional remote or by utilizing the Onboard Variable Settings. Additional features include an IEC removable 
power cable and multi-use bracket. 

The Radiance uses only Ultratec Special Effects Luminous 7 Haze Fluid which is a proven fluid that offers the 
best in low consumption with superior visual hang time. It can accommodate both the 2L or 4L sizes of the 
Ultratec fluid containers.

1. Ensure that any operation of the machine is supervised by suitably trained and authorized 
   personnel.
2. Do not modify the machine or use a machine which has been damaged in any way.
3. Allow sufficient air circulation around the machine at all times.
4. Protect the machine from direct weather effects and wet locations. Suitable for dry locations 
    only.
5. Only use Luminous 7 Water Base Haze Fluid by Ultratec Special Effects.
6. Do not continue to produce haze in an enclosed area when visibility is reduced below 
    20”(50cm).
7. Avoid direct haze output continuously at persons, structures or objects within close proximity of 
    the discharge nozzle.
8. Ensure that adequate exhausting arrangements are available in the event of an emergency.
9. Do not place hands or exposed skin within the first 20”(50cm) of the discharge nozzle at any 
    time during haze production.
10. Haze effects can trigger smoke alarms and detectors. Please take suitable precautions to 
      prevent false alarms.

Important Safety Instructions:

WARNING!!

Safety Precautions

WARNING!!

Introduction

1

www.ultratecfx.com

Содержание CLF2460

Страница 1: ...Radiance Hazer v 102020 Operators Manual ...

Страница 2: ...tions 2 Technical Drawings 2 Radiance Setup 3 Operating Procedure 3 Stand Alone Operation 3 DMX Operation 4 RDM Functions 4 Operation with Hand Remote 5 Maintenance Procedure 6 Troubleshooting 6 Recommended Fluid 6 Warranty 7 Contact Information 8 Table of Contents ...

Страница 3: ...uses only Ultratec Special Effects Luminous 7 Haze Fluid which is a proven fluid that offers the best in low consumption with superior visual hang time It can accommodate both the 2L or 4L sizes of the Ultratec fluid containers 1 Ensure that any operation of the machine is supervised by suitably trained and authorized personnel 2 Do not modify the machine or use a machine which has been damaged in any...

Страница 4: ...ater Base Haze Fluid Consumption settings from 27 380 cc hour Even lower output is achieved by using the Interval Timer Features 5 Pin USITT DMX 512 RDM Protocol Truss Mount Angle Floor Stand Power Cord 6 Detachable IEC Cord Heat up 8 Minutes Run Time Continuous Approvals 120V Full certification by T U V CE Certified 220 VAC CSA UL certified by QPS for 240 VAC Technical Drawings Technical Specificatio...

Страница 5: ...will consume any haze fluid that is still in your distribution feed tubes and processing block Failure to do so will result in raw fluid being discharged from your output nozzle when you operate it next start up and will help reduce not stop the residue buildup Note Stand Alone Operation overrides DMX and held held remote operation controls Radiance Setup Operating Procedure After power up the rear ...

Страница 6: ...LED on the back of the unit indicates heating when flashing and ready when solid A three flash pattern with the fan turning ON to full speed indicates an over temperature error The fan has a minimum setting and should always run when the power is applied The fan speed can only be changed when haze is being produced 4 15 Minutes prior to shutting down your Radiance Hazer adjust your output setting to...

Страница 7: ...utput increases as the variflow knob turns clockwise 6 The assist fan is always on low Fan speed can be increased by rotating the fan knob clockwise The fan only speeds up during haze output The Versa Fan Power Port output will also be adjusted 5 The interval knob is used to provide cycled output It must be set fully counterclockwise off when continuous haze output is required The hazer will produce...

Страница 8: ...Contact Ultratec Special Effects for more help with this UNIT DOES NOT PRODUCE HAZE 1 Check that fluid pick up hose is sufficiently submerged into fluid in jug 2 Ensure fluid pickup line is fully primed with fluid 3 Ensure that green heater status LED is ON solid indicating that unit is fully heated 4 If using Standalone Mode ensure DMX address is set to 600 and that the 10 s column is set between 1 8 5 ...

Страница 9: ...f the repair Ultratec Special Effects will return the unit via the most economical means available Should you require the item express returned the user dealer is responsible for indicating this request and for any difference in freight cost Warranty will be voided and customer will lose all rights guaranteed by the warranty if any of the following are observed occur If any non Ultratec Special Ef...

Страница 10: ... Effects GmbH Dieselstrasse 30 40 60314 Frankfurt am Main Germany Direct 49 69 87 000 1850 Fax 49 69 87 000 1899 Canadian Shipping Address For All Canadian Repairs Ultratec Special Effects 1960 Blue Heron Drive London Ontario N6H 5L9 USA Shipping Address For All USA Repairs Ultratec Special Effects 640 Gadson Street Groveland Florida 34736 Contact Us www ultratecfx com 8 ...

Отзывы: