background image

Technical Specifications

Model:   

Bubble Master/Bubble Master DMX

Part Number: 
CLB-2012  

Bubble Master 110V 

 

CLB-2015  

Bubble Master 110V w/FDS Option 

 

CLB-2014  

Bubble Master 220V (CE) 

 

CLB-2020  

Bubble Master 220V w/FDS Option 

 

CLB-2024  

Bubble Master DMX 110V 

 

CLB-2026  

Bubble Master DMX 110V w/FDS Option 

 

CLB-2025  

Bubble Master DMX 220V

CLB-2018  

Bubble Master DMX 220V w/FDS Option

CLB-2022  

Bubble Master Junior 110V

CLB-2023

  

Bubble Master Junior 220V

*Dimensions Include bubble projector*

Length:  

28.4in 72.1cm

Width:   

16.3in 41.4cm

Height:  

15.8in 40.1cm

Net Weight:  

21lbs 9.51kg

Power Rating: 

120 Volt A.C. 50/60 Hz. 1 Amps.  

 

 

240 Volt A.C. 50/60 Hz. 0.5 Amps.

Fluid: 

Water Base Bubble Fluid (Use only Ultratec Fluid)

Approvals: 

Field Certification Q.P.S.

This product has been certified to CSA/UL Standards by QPS Canada Inc
Product descriptions with (CE) included are CE Approved.

3

www.ultratecfx.com

Содержание Bubble Master

Страница 1: ...Bubble Master Bubble Master JR Bubble Master DMX Operation Manual www ultratecfx com v 072020...

Страница 2: ...ions 3 Technical Drawings 3 Set Up Procedure 4 Bubble Master Operation 4 Bubble Master DMX Operation 5 Shut Down Procedure 7 FDS Option 8 Troubleshooting 8 Maintenance 9 Recommended Fluid 9 Warranty 1...

Страница 3: ...d by suitably trained and authorized personnel 2 Do not modify the machine or use a machine which has been damaged in any way 3 Allow sufficient air circulation around the machine at all times 4 Prote...

Страница 4: ...ubble Master DMX 220V w FDS Option CLB 2022 Bubble Master Junior 110V CLB 2023 Bubble Master Junior 220V Dimensions Include bubble projector Length 28 4in 72 1cm Width 16 3in 41 4cm Height 15 8in 40 1...

Страница 5: ...the bubble outlet Fill up to 1 2 below the reservoir top This initially should take approximately 1 gallon NOTE Care must be taken when filling with bubble fluid to ensure that fluid does not overfil...

Страница 6: ...hash mark on remote label Suggest this dial be left at full CW Max setting This will allow the bubble wheel motor to turn OFF ON as soon as fans are turned OFF ON Interval Dial Not used for operation...

Страница 7: ...FF ON 0 49 Bubble wheel motor OFF 50 100 Bubble wheel motor ON 1 Set desired DMX address on thumb wheels between 001 to 511 2 Connect a 5 pin DMX cable to the DMX IN XLR 3 Turn power switch to ON posi...

Страница 8: ...when set from 1 8 9 is same speed as 8 PUSH PUSH 0 0 0 Valid DMX Remote DMX In DMX Out Address Shut Down Procedure 1 Disconnect the Bubble Master from the power source 2 Remove the bubble extension s...

Страница 9: ...LB 2010 Bubble Master FDS Pail CLF 4145 FDS Pump 110V CLF 4147 FDS Pump 220V Troubleshooting Bubble Wheel not turning 1 Ensure that unit is plugged into a suitable power source and that power switch i...

Страница 10: ...plugged gummed up from dried bubble fluid 4 Check that bubble master FDS pail has bubble fluid in it Contact Ultratec Special Effects for further assistance if neccessary Maintenance Fluid Reservoir...

Страница 11: ...f the repair Ultratec Special Effects will return the unit via the most economical means available Should you require the item express returned the user dealer is responsible for indicating this reque...

Страница 12: ...Effects GmbH Dieselstrasse 30 40 60314 Frankfurt am Main Germany Direct 49 69 87 000 1850 Fax 49 69 87 000 1899 Canadian Shipping Address For All Canadian Repairs Ultratec Special Effects 1960 Blue He...