Installation of the UltraCOM 4G panel
Before proceeding with the final installation of your UltraCOM 4G, we advise you
to test the state of the network at its location. This confirms that the intercom can
receive and transmit calls and texts without problems.
To do this, you can consult the network level ranging from 1 to 31 by requesting
a status report from your intercom with the
1234#STATUS
command (
1234 being
the default password, to be adapted if it changes
). We recommend a minimum
signal reception level of 17/31 (
see page 30
).
Fixing your intercom
The UltraCOM 4G intercom is compact, rugged and professional grade for outdoor
installation. The caller station meets IP54 standards and operates at temperatures
from -20˚C to 50˚C. In addition, the protective hood reinforces this resistance.
Pick a location that isn't too rough. We recommend a light polishing to achieve a
flat surface, otherwise you may not install the caller station correctly for the long
term.
1. Make marks on your wall using the
holes in the hood as a template.
2. Drill the wall with a bit corresponding
to the diameter of the dowels provided (
or
other dowels depending on the support
).
3. Then insert the dowels into the holes.
4. Pass all the cables necessary for your
installation (
remote antenna, power supply,
relay, switch, etc.
) through the wall and the
central hole in the visor provided for this purpose.
Important: remember to install your panel in a place where the coverage
of the mobile network is good. Receive network status report by SMS
command (
see page 24
).