Regenerant Line Connection
15
Rev A
Regenerant Line Connection
(not used with 3-cycle filter system)
The regenerant line from the tank connects to the valve. Make the
connections and hand tighten. Be sure that the regenerant line is secure
and free from air leaks. Even a small leak may cause the regenerant line to
drain out, and the conditioner will not draw regenerant from the tank. This
may also introduce air into the valve causing problems with valve
operation.
Ensure that pipe sealant (Teflon* tape) is applied to the 3/8-inch NPT
regenerant line connection.
Figure 4 Regenerant Line
Connection
*Teflon is a trademark of E.I. duPont de Nemours.
NOTE:
When installing a 3-cycle filter (263 valve) use a cap on the
regenerant line connection to prevent water seepage from the port. See
Parts
List
for part number.
Regenerant Line Connection