WIRING AND OPERATION
MERCURY SLIM
WIRING AND OPERATION
Motor Controller Speciation
•
Input: 220 VAC / 50 Hz ± 10%
•
Output: 220 VAC
•
Power: Max. 500 W
•
Maximum motor running time: 5 minutes
•
Both RF and IR receiver
•
Dry contact closures.
•
External IR Lead & Built in IR Eye.
•
12 Volt trigger input for projectors
•
Programmable
Pairing Remote Control to Receiver:
Aim the Remote-control unit towards the receiver IR eye (IR1) or to the external IR eye while
programming.
Push button switch (SW4), (LED1 blinks) then press the UP button of the remote-control unit.
Unpairing Remote Control from Receiver:
Press SW4 (LED1 blinks) then press the DOWN button of the remote-control unit.
Unpairing All Remote Controls from Receiver:
Press and hold SW4 for about 4 seconds until LED1 blinks at faster rate, then release the Button. Then
press SW4 again.
Reversing The Up-Down Button Direction:
Press SW4 (LED1 blinks) then press the STOP button of the remote-control unit.
HEX Codes
Up
0x0B
Down 0x43
Stop 0x23
Mo tor Controller Box (Side View )