F. TEST START-UP 

    To test operate an Ultrafryer gas fryer equipped with an Ultrastat 23 Cooking computer: 

1. Ensure the fryer‟s On/Off switch is in the OFF position. 

2. Ensure the fryer vat is filled with hot or cold water to the middle of the “E” in the word LEVEL on the rear of the vat. 

3. Turn the MANUAL gas valve to the OFF position and wait FIVE (5) minutes for any accumulated gas to disperse. 
4. ENSURE the MAIN gas shut-off valve is in the ON position and that the Vent Hood EXHAUST FAN is ON. 
5. Turn the MANUAL gas valve to the ON position. 
6. Perform the following steps, in the order listed: 

 
 
 
 
 
               
                            
 
 
 
 
 
              
 
 
 
 
 
 
 
 
 
               
 
 
 
               
 

 
 
 
 

STEP 

ACTION 

RESPONSE 

Ensure the drain valve lever is in the closed position 
and that water is at the proper level; then turn the On/
Off switch to the ON position. 

The 

AMBER 

power lamp beside the fryer On/Off switch will illuminate. 

Spark will light pilot flame. 

Turn the computer ON by depressing the computer 
On/Off button; then place the computer in the BOIL 
mode by pressing the P key scroll to boil press P key 
again to activate.  

A. BOIL will appear in the computer display. 
B. The HEAT lamp on the computer and the 

RED 

burner indicator lamp on 

the fryer will cycle ON and OFF to heat the water to 190˚F (88˚C) 

When the water reaches temp 190

 F (87.8

 C), the 

heat light will go off.  To Exit, Press the on/off  
button. 

A. Boil appears in the display heat indicator light goes off. 
B. OFF appears in the display. 
 

Turn the computer OFF by depressing it‟s On/Off 
button then turn the on/off toggle switch to the OFF 
position. 

A. The computer display will go BLANK. 
B. The 

AMBER 

power lamp will extinguish. 

After the water in the vat and the fryer metal surfaces 
have COOLED drain the water into a floor drain. 

 

CAUTION: 

PRIOR TO PROCEDING TO STEP 1, VISUALLY CHECK THAT THE HEAT EXCHANGER TUBES ARE COV-

ERED BY AT LEAST 2” (51MM) OF WATER. 

Page 11 

30A134

 

Shortening Level 
Mark 

              Fryer On/Off Switch 

Main Gas Valve

 

Manual Gas Valve

 

Содержание PAR-3-14HE CE

Страница 1: ...TH HARD DOCK FILTRATION Operating Instructions 302 Spencer Lane P O Box 5369 San Antonio Texas 78201 800 525 8130 210 731 5000 Fax 210 731 5099 www ultrafryer com THIS APPLIANCE IS FOR PROFESSIONAL US...

Страница 2: ...cket CAUTIONS These items will be indented from the main body of text the word CAUTION will be in bold capitalized print and the entire text will be enclosed by a border These items identify steps or...

Страница 3: ...al 6 Rating Plate 6 Clearances 6 Standards 6 Air Supply Ventilation 6 RECEIVING INSTALLING Unpacking 7 Installing 7 Leveling 7 Gas Connection 8 Electrical Connection 8 INITIAL START UP Cleaning 10 Sta...

Страница 4: ...rastat 23 Start Up and Cooking Computer Operation 23 FILTER TUB ASSEMBLY INSTALLATION Filter Tub Assembly 24 Filter Tub Installation 24 FILTERING POLISHING SHORTENING Filtering Shortening 25 26 Polish...

Страница 5: ...18 gauge stainless steel and is equipped with an Ultrastat 23 Cooking Computer In addition the fryer is equipped with the NEWLY developed Hard Dock Filtration System that uses a stainless steel Filter...

Страница 6: ...and other factors that affect the cook cycle Under STRAIGHT time mode the product is cooked at a specified temperature for the length of time programmed without adjusting for these variations Operati...

Страница 7: ...ure Controller These controls are mounted on the Temperature Control access Panel and other fryer controls are located behind the access door The main drain valve and shortening return levers are loca...

Страница 8: ...or and manual valve 3 Sensing circuit within the spark ignitor module to turn gas to the fryer OFF if a burner FLAME OUT occurs 4 A Drain Valve Safety Switch that will DISABLE the fryer each time the...

Страница 9: ...4a 30A134...

Страница 10: ...30A134 4b...

Страница 11: ...30A134 4c...

Страница 12: ...ryer equipment must be performed by Qualified Certified Licensed and or Authorized installation or service personnel Qualified personnel must be experienced in such work be familiar with all gas preca...

Страница 13: ...1 2 psig 3 45kPa 2 The fryer must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at pressures...

Страница 14: ...32mm flexible gas hoses 4 feet long 1219mm with a quick disconnect coupling on one end are available from Ultrafryer Systems under PN 24322 3 4 19mm hose PN 24323 1 25mm hose and PN 24456 1 1 4 32mm h...

Страница 15: ...not only dangerous but will often miss small leaks that a soapy solution would find 6 Flexible Couplings Connectors The gas inlet to the appliance shall have a thread conforming to EN 10226 2 2004 EN...

Страница 16: ...E AREA SURROUNDING THE FRYER MUST BE KEPT FREE AND CLEAR OF ALL COMBUSTIBLES IV DO NOT GO NEAR THE AREA DIRECTLY OVER THE FLUE OUTLET WHEN THE FRYER S MAIN BURNERS ARE OPERATING V ALWAYS WEAR OIL PROO...

Страница 17: ...spark will light the flame Ensure the pilot is lit then place the ULTRASTAT 23 Cooking Computer into the MELT MODE D SEQUENCE OF IGNITION When the lighting instruction steps are performed in the sequ...

Страница 18: ...2 Turn the computer ON by depressing the computer On Off button then place the computer in the BOIL mode by pressing the P key scroll to boil press P key again to activate A BOIL will appear in the c...

Страница 19: ...reach to the middle line of the E in the word LEVEL of the shortening level mark on the rear wall of the fryer 2 If shortening is needed Add a small amount to bring shortening to the proper level 3 Re...

Страница 20: ...s are in their proper position b Check that the fryer electrical plug is connected to an electrical receptacle c Ensure the applicable Circuit Breaker is in the ON position and that the fryer ON OFF s...

Страница 21: ...mperature recovery is slow and main burner flames are small and appear to be lethargic A Ensure that the MANUAL GAS VALVE is completely open B Check for an obstruction in the gas line C Check for an o...

Страница 22: ...ED TO WARNING DO NOT ALLOW ANY CLEANING SOLUTION OR WATER TO SPLASH INTO A VESSEL OF HOT COOKING OIL AS IT WILL CONTAMINATE THE OIL AND MAY CAUSE THE OIL TO SPLATTER CAUSING SEVERE BURNS WARNING CRUMB...

Страница 23: ...NGER LOOP on the straight side of FRAME B then HINGE it to remove FRAME B from the FILTER SCREENS d Separate the UPPER FILTER SCREEN and BAFFLE from the LOWER FILTER SCREEN e CAREFULLY clean the two f...

Страница 24: ...ter Tub in front of the FILTER TUB GUIDES beneath the fryer then CAREFULLY and SLOWLY insert the Filter Tub into the fryer using the Standpipe Docking Handle until the MALE In Line Plug on the Standpi...

Страница 25: ...he Electric and Manual Gas valves Ignitor Rod and Module as well as the High Limit Temperature switch are lo cated behind the Service Access door The Hard Docking Filtration system and Drain levers ar...

Страница 26: ...nt times in a cook cycle In addition the operator can program the ULTRASTAT 23 computer to cook products under FLEX or STRAIGHT timing modes When programmed for FLEX time mode the computer will adjust...

Страница 27: ...ammed 9 ENTER EXIT FILTER KEY This key will force a filter the fryer into the filter mode This key is an optional feature 10 TEMP TOGGLE CLEAR KEY a In operating mode displays the actual temperature f...

Страница 28: ...D DISPLAY DESCRIPTIONS 30A134 Page 21...

Страница 29: ...ON by depressing the computer ON OFF button A The MELT lamp will LIGHT to indicate the computer is in the SHORTENING MELT MODE B The HEAT lamp on the computer and the RED heat mechanism indi cator lam...

Страница 30: ...emperature HEATING will appear in the display to indicate the shortening temperature is MORE than 20 F 6 6 C BELOW the setpoint temperature When shortening temperature rises to the SETPOINT tem peratu...

Страница 31: ...LE DOCKING PLUG over the leading edge of the pan 4 Position the FILTER TUB COVER on the open end of the Filter Tub with the SLOT on the cover seated around the Standpipe Docking Handle Assembly Then S...

Страница 32: ...ock wise to automatically return shortening in the filter tub through the SWEEP NOZZLE in the bottom of the vat When all shortening has been returned to the vat turn the LEFT HAND Vat Shortening Retur...

Страница 33: ...tening RE TURN LEVER 1 4 COUNTER CLOCKWISE to automatically return shortening in the filter tub to the fryer vat 3 When all shortening in the filter tub has been returned to the fryer TURN the VAT SHO...

Страница 34: ...burner tubes and all walls of the vat until all the sediment and residue at the bottom of the fryer has been flushed through the drain into the filter tub Then turn the Topside Shortening Return Lever...

Страница 35: ...nse the fryer with hot water until the water coming out of the drain valve is clear 10 Mix a solution of ONE PART vinegar to 25 PARTS of water Place this mixture into a one gallon garden pressure spra...

Страница 36: ...eld World Trade U S Office 3355 Enterprise Ave Suite 160 Ft Lauderdale FL 33331 Website www Greenfieldworld com 2 DAMAGES Ultrafryer Systems is not responsible for damage occurring in transit All deli...

Страница 37: ...tc then obtain the part number and description for that index number on the page facing the sketches Use that part number when ordering a replacement part ULTRAFRYER MODEL PAR 3 HE CE GAS FRYER FRONT...

Страница 38: ...ark Ignitor Rod Assembly Set Rod Gap to 5 32 4mm prior to installation 12C196 15 Pilot light Heat Channel 19C271 16 Docking Release Handle 19A948 17 14 Model PAR 3 H CE F F Basket Hanger Bracket 19A94...

Страница 39: ...H CE 53 4 x 8 High 146 x 208mm Rectangular Flue Tube with deflector 19A910 9 Medium Duty 3 76mm Rear Caster w out Brake 28A011 10 Electrical Box Assy 12C195 11 240 Volt 75 Watt Silicon Heater 5 1524m...

Страница 40: ...craper 12567 2 Micromesh S S Filter Screen Assembly with StandPipe Docking Assembly 12B113 3 Magepad Magnesol Impregnated Filter Pad with Standpipe and Docking Assembly 12B178 4 Wash Down Hose Assembl...

Страница 41: ...Iron Close Nipple 24003 6 3 8 10mm x 7 177 8mm Black Iron Nipple 24470 7 1 2 13mm S S Locking Seal Inline Plug 24A208 8 1 2 13mm Handle Assy With 90 Black Iron Elbow 19A598 9 Top Compression Cap Knurl...

Страница 42: ...30A134 PAR 3 H CE GAS FRYER W U23 COOKING COMPUTER Page 35 WIRING DIAGRAM...

Страница 43: ...THIS PAGE INTENTIONALLY BLANK Page 36 30A134...

Отзывы: