7
2. WATER CONNECTIONS
Important: before proceeding with the water connections,
make sure that DI water connections and drain are not reversed.
Damage is not under warranty
2.1 Supply water
The ultrasonic humidifier works on DI water . Using normal water will
shorten transducer life; specifically, maintenance intervals for cleaning or
replacing transducers depend on to what extent the supply water mineral
content exceeds the values recommended in Table 11.b (p.24). In the case
of use RO or city water use, Reduction in the production of moisture
declared in Table 11.a due to salts and impurities present.
Operating conditions:
DI water with the characteristics indicated in Table 11.b, supply water
(p. 24);
pressure between (14.5 and 58 PSI), temperature between (33.8 and
104 °F).
Temperature and Humidity conditions that change throughout day will
also change the distance of absorption. Please allow for 60” clear space in
front f humidifier
Important:
•
do not add disinfectants or anticorrosive compounds to the water, as
these are potential irritants;
•
the use of well water, industrial water or water from cooling circuits
in general, or potentially chemically or bacteriologically contaminated
water is prohibited.
2.2 Drain water
Drain water from the humidifer is not toxic and can be drained into the
approved drain system.
Attach 1/2" FPT (female pipe thread) safety drain on bottom of cabinet
and 3/8" push connection on side f cabinet to approved drain
3. MIST DISTRIBUTION OPTIONS
3.1 Mist distributors (Optional)
Important:
Optional plastic wand and S/S distributor, front
diffuser, fan conveyor and elbow connector are not supplied with the
humidifier
Code
Tube & S/S wand
Plastic flexable hose
Part #
10" UP_P 0553-1
21" UP_P 0553-2
24" UP_P 0553-3
33" UP_P 0553-4
39" UP_P 0553-5
Fan Conveyor
UP_P_0554
Elbow Connector
UP_P_0555
Diffuseer
UP_P_0556
50M Filter
UP_P_0557
Requirements:
•
minimum 1 mist distributer is required for proper operation
•
slope S/S distributor so any water that may accumualate inside pipe
will drain into P trap or back into humidifer
•
use hose clamp to securly tighten hose to S/S tube.
•
confirm water in S/S distributer does not leak out of connection to
hose
•
position the distributor in such a way that the air is not directed against
nearby objects (minimum distance 5ft);
•
bends or choking the hose may cause condensate to form and decrease
humidity delivery;
•
avoid loads that may cause mechanical stress on the humidifier outlet
connector.
Fig. 3.a
Fig. 3.b