Initial Start-up Step-By-Step Instructions
37
Rev B
7. Draw water from the regenerant tank.
A. From the treated water position (cycle C0), advance the valve to the
draw regenerant position. Hold the REGEN button down for five
seconds.
The controller will begin a manual regen, and advance the control
valve to the cycle C1 (Backwash). Press the SET and UP button to
advance to cycle C2 (Draw).
B. With the controller in this position, check to see that the water in the
regenerant tank is being drawn out of the tank. The water level in
the tank should recede very slowly.
C. Observe the water being drawn from the regenerant tank for at
least three minutes. If the water level does not recede, or goes up,
check all hose connections. C2 should be displayed.
8. If the water level is receding from the regenerant tank you can then
advance the controller back to the treated water (C0) position by
pressing SET and the UP buttons simultaneously to advance the
controller to the C0 position.
9. Finally, turn on a faucet plumbed after the water conditioner. Run the
faucet until the water runs clear.