6
Rev B
QUI
C
K
S
T
A
R
T
Step 9: Enter Hardness (762 Demand Control Only)
•
Enter inlet water hardness at installation site.
•
Default hardness setting is 25 grains (25 ppm for metric)
•
To change hardness, press SET to make the setting flash. Use the UP and
DOWN buttons to scroll to the correct hardness.
•
Press SET to accept the entered hardness value.
•
The control will return you to the normal operation mode.
Initial system programming is now complete. The control will return to normal
operation mode, if a button is not pushed for 30 seconds.
For system start-up procedure, including: purging the mineral tank, refilling the regenerant tank, and drawing
regenerant, see
Initial Startup Step-By-Step Instructions
on page 29.
Manual Regeneration Procedures
To Initiate a Manual Regeneration:
•
Press REGEN once for delayed regeneration.
System will regenerate at next set regen time (2:00 AM).
A flashing regen (recycle) symbol will be displayed.
•
Press and hold REGEN for 5 seconds to initiate immediate manual
regeneration. A solid regen symbol will be displayed.
•
After immediate regeneration has begun, press REGEN again to initiate a
second manual regeneration. An X2 symbol will be displayed, indicating a
second regeneration will follow the first regeneration.
During a Regeneration:
•
A "C#" is displayed to show current cycle.
•
Total regen time remaining is displayed on screen.
•
Press and hold SET to show current cycle time remaining.
To Advance Regeneration Cycles:
•
Press and hold SET - showing current cycle time.
•
Simultaneously press SET and UP to advance one cycle.
An hourglass will display while cam is advancing.
When cam reaches next cycle, "C2" will be displayed.
•
Repeat SET and UP to advance through each cycle.
•
Press and hold SET and UP buttons for 5 seconds to cancel regen.
Hourglass will begin flashing, indicating regen is cancelled.
Camshaft will advance to home - may take 1-2 minutes.
Regeneration Cycles:
•
C1 - Backwash
•
C2 - Regenerant Draw/Slow Rinse (not used in filter mode)
•
C3 - Slow Rinse (not used in filter mode)
•
C4 - System Pause (to repressurize tank)
•
C5 - Fast rinse
•
C8 - Regenerant refill (not used in filter mode)
Time & Day
Regen Time & Day
Salt
SU MO TU WE TH FR SA DAYS
C
Capacity
Hardness
MIN
x2
Cycle Indicator
Regen Symbol
Second Manual Regen Symbol