Ultra-Aire SD12 Installer’s & Owner’s Manual

12

3.9C Ducting for Fresh Air

 

Fresh air can be brought into the structure by connecting an 
insulated duct from outside to the 6” Ultra-Aire SD12 inlet and by 
turning on the fan switch or activating the humidity control (on units 
with the humidity control panel). Activate the ventilation timer on 
the remote control to bring in fresh air. Refer to Section 7.8B for 
programming instructions for the ventilation timer. Advantages of 
this form of ventilation include: 

1. Outside air is filtered before entering the building. 
2.  Outside air will be dehumidified and cooled before entering if the 

Ultra-Aire SD12 is running in dehumidification mode. 

3.  Drawing air from outside and blowing inside aids in slightly pres-

surizing the structure. This helps prevent dirty and humid air from 
entering elsewhere. It also reduces the potential for carcinogenic 
radon gas to enter and provides make-up air for open combus-
tion and exhaust devices like the clothes drier, fireplace, and 
water heater. 

4.  Adequate exhaust fans are recommended in the bath rooms and 

kitchen. 

In cold climates or areas where the outdoor dew point is low at 
times, ventilation can be used to dehumidify the structure. This 
is accomplished by bringing the dry, low dew point air into the 
structure during these times. This approach is often more economi-
cal than running the dehumidifier to remove excess moisture from 
the structure. In cold climates, it is critical to adequately ventilate to 
reduce the inside moisture content to avoid moisture accumulating 
in the wall cavities. For example; in a house that experiences con-
densation on the interior surface of the windows during the winter, 
increasing the amount of ventilation will often cure the problem. 

An insulated 6” diameter duct is generally sufficient to provide up 
to 100 CFM of outside air. Large quantities of outside air will either 
positively or negatively impact the performance of the Ultra-Aire 
SD12, depending upon inside and outside air conditions. Consult 
the factory by calling 1-800-533-7533 for recommendations re-
garding the use of higher flows with your specific application. 

The outside air duct should be connected to the 6” round collar 
on the filter enclosure of the unit. The 6” round collar includes a 
manual damper. Adjust the manual damper to provide the desired 
amount of fresh air for ventilation. The amount of fresh air should 
be based on the size and occupancy of the residence. If you are 
unsure of your ventilation air requirements, consult the factory by 
calling 1-800-533-7533 for assistance or check your local building 
codes.

3.9D Installation in a Basement or Crawlspace with an 

Existing Forced Air HVAC System

 It is recommended that a new, separate return duct be installed 

FOR HVAC INSTALLER ONLY

for the Ultra-Aire SD12 from a central area of the house. If this is not 
possible, and if the existing system has multiple returns, select one 
to disconnect from the existing forced air system and use it for the 
dedicated Ultra-Aire SD12 return. Always select a return from a central 
location in the structure in an area that is always open to the rest of 
the structure. Do not use a return from a room that may have its door 
closed much of the time.

If the structure in which the Ultra-Aire SD12 is to be installed has an ex-
isting forced air HVAC system, utilize the HVAC system ducting to make 
the Ultra-Aire SD12 installation easier. 

Basement Installation:

 Install a separate 10” return for the Ultra-Aire 

SD12 in a central area of the structure. Duct the supply of the Ultra-Aire 
SD12 to an optional 10” x 10” x 10” tee/damper that is 20% open to the 
basement. This allows the dehumidifier to discharge a variable amount 
of dehumidified air into a basement that may not be well served by the 
existing duct system. Duct the other side of the tee to the air supply of 
the existing HVAC system. A backdraft damper is required in the duct 
between the 10” tee and the central supply duct to prevent air from be-
ing discharged into the basement during central fan operation. Connect 
a duct from outside to the 6” collar of the Ultra-Aire SD12 if you wish to 
provide fresh air ventilation. 

Crawl Space Installation:

 Install a separate return for the Ultra-Aire 

SD12 in a central area of the structure. Duct the supply of the Ultra-
Aire SD12 to a 10” x 10” x 10” tee/damper that is 20% open to the 
crawl space if desired. Duct the other side of the tee to the air supply 
of the existing HVAC system ventilation. Connect an insulated duct from 
outside to the 6” collar of the Ultra-Aire SD12 if you wish to provide 
optional fresh air. 

FIGURE 14A: DEHUMIDIFIER BASEMENT INSTALL

Содержание SD12

Страница 1: ...her temperature to provide additional cooling if needed By eliminating the HVAC system s need to control latent load the Ultra Aire SD12 allows the system to work more efficiently Fresh Air Ventilatio...

Страница 2: ...tallation in an Attic with an Existing Forced Air HVAC System 13 3 9F Installation in a Structure with Two Forced Air HVAC Systems 13 3 9G Installation in a Structure with No Existing Forced Air HVAC...

Страница 3: ...y before installing and operating this device Proper adherence to these instructions is essential to obtain maximum benefit from your Ultra Aire SD12 indoor air quality system WARNING IMPROPER INSTALL...

Страница 4: ...ed living area or above an area where water leakage could cause damage Place the Ultra Aire SD12 on supports that raise the base of the unit 2 5 above the drain pan beneath it Raising the Ultra Aire S...

Страница 5: ...IN DAMAGE TO ROOF SURFACE Mount the base of the condensing unit to a sturdy level pad or bracket using 3 8 10mm bolts The condensing unit may be mounted to a wall with brackets or placed on a roof En...

Страница 6: ...sunlight or near a pool or spa The installer must supply the control wiring between the Ultra Aire SD12 dehumidifier the condensing unit the remote control and any electrical accessories Carefully rou...

Страница 7: ...er use either metal strapping material or anchored heavy nylon wire ties ANCHORED HEAVY NYLON WIRE TIRE OR AUTOMOTIVE MUFFLER TYPE HANGER AUTOMOTIVE MUFFLER TYPE HANGER WALL STUD STRAP LIQUID LINE TO...

Страница 8: ...stub tubes of condensing unit These service ports can be used to introduce and release nitrogen during brazing Use the following procedure to connect the line set to the Dehumidifier CAUTION THE DEHU...

Страница 9: ...COVERED RESPONSIBLY FAILURE TO FOLLOW THIS WARNING MAY RESULT IN PERSONAL INJURY OR DEATH 1 Connect the HFC 410A manifold gage set high pressure hose to the service port on the suction gas line Note C...

Страница 10: ...to charge the system FOR HVAC INSTALLER ONLY 3 7 Charging the System The condensing unit is pre charged with 42 oz of HFC 410A refrigerant The installer will add HFC 410A refrigerant for the dehumidif...

Страница 11: ...parate supply duct from the Ultra Aire SD12 to each isolated area is recommended DO NOT draw air directly from the kitchen laundry or isolated basement You may draw air from a basement that is open to...

Страница 12: ...ter enclosure of the unit The 6 round collar includes a manual damper Adjust the manual damper to provide the desired amount of fresh air for ventilation The amount of fresh air should be based on the...

Страница 13: ...the struc ture such as bedrooms den etc By ducting this way the air inside the structure will circulate through the Ultra Aire SD12 to be filtered and dehumidified Avoid discharging all the air from...

Страница 14: ...AMAGE the transformer Dehumidifier on Connect yellow and blue wires Fan only on Connect yellow and green wires Accessory power 24volt AC power supply available for HVAC accessories between yellow and...

Страница 15: ...t 35 min 70 max Auxillary Relay Capacity 5 Amps 24VAC Temp Range Accuracy 30 90 F 2 F Size 4 95 L x 1 06 W x 4 19 H Major Operations n Digital control of Relative Humidity Digital Set Point n Fan Filt...

Страница 16: ...during the seasons when there are many particles in the outdoor air 6 5 Condensing Unit Maintenance The compressor and fan motor inside the condensing unit are permanently lubricated for many years o...

Страница 17: ...nplugged or no power to outlet 2 Loose connection in dehumidifier fan circuit 3 Obstruction prevents fan impeller rotation 4 Defective fan 5 Defective fan relay 6 Defective impeller run capacitor Low...

Страница 18: ...t be replaced if continuity exists across its terminals If there is no needle movement with the meter set on the Rx100000 FOR HVAC INSTALLER ONLY scale the capacitor is open and must be replaced 4 Mar...

Страница 19: ...or and an over sized liquid line filter In a running burn out install an oversized suction line filter drier be tween the accumulator and compressor Thoroughly flush the accumu lator with refrigerant...

Страница 20: ...ng is correct and that voltage is present at the damper motor 2 Check for any obstruction inside the damper If the electric ventilation damper fails to operate after performing these checks it must be...

Страница 21: ...CE PARTS LIST Condensing Unit Item Part No Qty Description 2 4033211 1 Nut 3 4033212 1 Fan Axial 16 4033213 1 Compressor 20 4033214 1 Capacitor 23 4033216 1 Capacitor Fan Motor 30 4033215 1 Motor 31 4...

Страница 22: ...mounting hardware from inside the rectangle opening Mount the duct collars to the front of the dehumidifier using screws provided Collars and hardware are located here Door Install Insert tab on the...

Страница 23: ...osts related to changes to a Product or Component that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer Customer Responsibil...