UAWSB 2 A1
■
4
│
GB
│
CY
Attention! Avoid damage caused by
improper use!
■
Only use the appliance with the included original
parts!
■
Keep the electrical contacts of the battery free of
dust and lubricants. Clean the contacts with a clean
cloth as required.
Connection
●
First connect the red quick-connect terminal clamp
to the positive pole (+) of the battery.
●
Then connect the black quick-connect terminal clamp
to the negative pole (−) of the battery.
The appliance can be fastened to the vehicle chassis
during the measurement using the magnetic strip
on the back of the appliance.
Testing a battery and generator
Select operating mode
●
Set the operating mode switch on the appliance
side to 6 or 12 volts, depending on the type of
battery you are testing.
Battery test/start capability
●
If only the “Charge very low” LED lights up, the
charge level of the battery is weak. In this LED status,
the electrical voltage in 6 volt mode is approximately
5.8 volts and in 12 volt mode approximately 11.5 volts.
The battery needs to be charged.
●
If the “Half charged” LED also lights up, the battery is
around 50% charged. In this LED status, the electrical
voltage in 6 volt mode is approximately 6.1 volts and
in 12 volt mode approximately 12 volts. We recommend
charging the battery.
●
If the “Fully charged” LED also lights up, the battery
is fully charged and start capable. In this LED status,
the electrical voltage in 6 volt mode is approximately
6.4 volts and in 12 volt mode approximately 12.6 volts.
Attention! Property damage!
Before
charging, learn about how to maintain the battery
by reading its operating instructions!