background image

9

pezo™

  Assembly and disassembly instructions

2

Assembly instructions

Assembling the correction 
instrument

The correction instrument sleeve 
CS 3361-05 (Sleeve correction 
instrument, length 410 mm) and 
the locking rod for the correction 
instrument CS 3361-06 (Locking 
rod correction instrument, length 
410 mm) are stored in a pre-
assembled condition. To assemble 
the instrument, first take the 
locking rod out of the sleeve. 

Set CS 3361-09 (Adjustor 
correction instrument) on the 
sleeve of CS 3361-01/-05 
(Sleeve correction instrument, 
length 300 mm/410 mm) and 
tighten it counterclockwise by 
means of the thread (left-handed 
thread). It is important to firmly 
tighten CS 3361-09 (Adjustor 
correction instrument).

Then set CS 3361-02/-06 (Locking 
rod correction instrument, length 
300 mm/410 mm) in the sleeve of 
CS 3361-01/-05 (Sleeve correction 
instrument, length 300 mm/410 mm) 
and push it all the way forward.

The hook of CS 3361-02/-06 
(Locking rod correction instrument, 
length 300 mm/410 mm) 
looks ahead of the sleeve 
of CS 3361-01/-05 (Sleeve 
correction instrument, length 
300 mm/410 mm).

Содержание CS 3360-01

Страница 1: ...pezo PEEK cage family Assembly and disassembly instructions with special cleaning instructions...

Страница 2: ...and storage The product descriptions in the component overview and in the descriptive text are listed in English according to the inscription on the instruments The user has to ensure that the latest...

Страница 3: ...4 8 pezo Assembly and disassembly instructions 2 pezo assembly and disassembly instructions for CS 3360 XX inserter pezo assembly and disassembly instructions for CS 3361 XX correction instrument Cont...

Страница 4: ...nd disassembly instructions for CS 3360 XX inserter CS 3360 XX inserter consisting of No Product number Product description 1 CS 3360 01 05 Inserter length 300 mm 410 mm 2 CS 3360 02 06 Locking rod le...

Страница 5: ...r length 300 mm 410 mm Then slide CS 3360 02 06 Locking rod length 300 mm 410 mm into CS 3360 01 05 Inserter length 300 mm 410 mm CS 3360 09 Adjustor must be secured against falling out By turning CS...

Страница 6: ...06 Locking rod length 300 mm 410 mm backwards until it is visible on the handle Then take CS 3360 02 06 Locking rod length 300 mm 410 mm out of CS 3360 01 05 Inserter length 300 mm 410 mm CS 3360 09 A...

Страница 7: ...Assembly and disassembly instructions Special cleaning instructions No special cleaning instructions The general cleaning instructions contained in the Processing manual implants and instruments UH 11...

Страница 8: ...instrument CS 3361 XX correction instrument consisting of No Product number Product description 1 CS 3361 01 05 Sleeve correction instrument length 300 mm 410 mm 2 CS 3361 02 06 Locking rod correction...

Страница 9: ...Adjustor correction instrument on the sleeve of CS 3361 01 05 Sleeve correction instrument length 300 mm 410 mm and tighten it counterclockwise by means of the thread left handed thread It is importa...

Страница 10: ...correction instrument Pull CS 3361 01 05 Sleeve correction instrument length 300 mm 410 mm out of the sleeve of CS 3361 02 06 Locking rod correction instrument length 300 mm 410 mm Loosen CS 3361 09 A...

Страница 11: ...ssembly and disassembly instructions 2 Special cleaning instructions No special cleaning instructions The general cleaning instructions contained in the Processing manual implants and instruments UH 1...

Страница 12: ...ulrich GmbH Co KG l Buchbrunnenweg 12 l 89081 Ulm l Germany Phone 49 0 731 9654 0 l Fax 49 0 731 9654 2705 spine ulrichmedical com l www ulrichmedical com WS 3385 EN Doc No 153716 R0 1...

Отзывы: