Page 70
M4220170607EN
UI Robot Technology Co. Ltd.
UIM2842
10. ENA
η
Set enable time
Format:
ENA
;
Description:
Set auto-enable time register ENAtimer.
Controller auto-enable the H-bridge circuit afer power is on for
ms.
= 1,2,
…
,60000;
ACK:
AA [Controller ID] A0 [E0] [E1] [E2] FF
Comment:
A0
>> Message ID of instruction ENA
;
[E0] ~ [E2]
>> Received data 0 ~ 2
[E0] ~ [E2] is the converted value for auto-ENA time (16 bits) (Figure 12-
1), units: ms.
Note:
This instruction sets ENAtimer only, can not enable controller.
In order to enable controller after pre-set time, user needs to configure
initial configuration register by using instruction ICF after ENAtimer is set.
Require controller hardware version being 1232 or higher.