background image

CX6192 

O

PERATION

 

 

19 

6

 

Operation 

6.1

 

Waking up 

Automatic wake-up is disabled for the cabinet lock in the delivered condition. To 
check the authorisation of a key, it needs to be woken up from the sleep mode. 

 

To wake-up the reading unit, press the button on the front of the cabinet lock 
until the LED glows. 

 

Hold up the key in front of the reading unit only after this. 

 

6.2

 

Open / close the door 

 

Wake up the cabinet lock by pressing the button. 

 

Hold the authorised key in front of the reading unit till the green LED starts 
glowing. 

 

Open or close the cabinet by turning the operating lever by 90°. Immediately 
after turning the lever, but after the locking time (default 5 seconds), the 
cabinet lock disengages again. 

              

 

 

 

       Opening    

 

 

Closing 

6.3

 

Toggling the cabinet lock 

 

Hold the key with toggle authorisation for two locking cycles in front of the 
reading unit. 

Depending on the initial state, the cabinet lock either engages or disengages 
permanently.

 

Содержание CX6192

Страница 1: ...CX6192 Clex prime Electronic cabinet lock Operating and assembly manual...

Страница 2: ...tra e 2 4 97297 Waldb ttelbrunn Germany Tel 49 931 40672 0 E Mail contact UundZ de http www UundZ de This operating and assembly manual is copyright protected The information contained this manual sho...

Страница 3: ...ories 11 4 Assembly 13 4 1 Assembly instructions 13 4 2 Assembly 14 5 Commissioning 16 5 1 Managing the locking system 16 5 2 Advanced cabinet lock settings 16 5 3 Configuring the cabinet lock 18 6 Op...

Страница 4: ...oes not assume any responsibility for disruptions or hazards such as non access to injured personnel malfunctions property damage or other damages resulting from non compliance with this operating and...

Страница 5: ...shers etc 2 3 General safety instructions Follow these basic safety instructions when using the cabinet lock Installation and battery replacement should only be done by qualified technicians according...

Страница 6: ...for left or right cabinet doors Advanced setting options free selection of cabinet mail box function No cabling required Can be combined with other systems for example Clex private Versions for HITAG...

Страница 7: ...gardless of the time zones applicable for the key For detailed information on the automatic expiry date please refer to the Keyvi software manual 3 1 4 Wireless network If a corresponding wireless net...

Страница 8: ...unit then the red LEDs flash 5 times accompanied by 5 short audible signals The engaging of the cabinet lock is delayed by 5 seconds during which time the green LEDs flash The battery needs to be cha...

Страница 9: ...Phase 3 Toggle off Toggle On Unknown position Service mode Radio diagnosis Automatic wake up off Wireless opening not OK Wireless opening OK The following information are recorded for every event Eve...

Страница 10: ...y 7 Button for manual activation 3 Lock washer 8 Battery 4 Mounting nut locking lever 9 Battery compartment 5 Operating lever 3 3 Options Different versions are available 3 versions of the locking lev...

Страница 11: ...MIFARE DESFire Active transponder 868 MHz Version 3 LEGIC 13 56 MHz LEGIC prime LEGIC advant MIFARE DESFire Active transponder 868 MHz Power supply Battery ER14505M 3 6V 1 piece Battery life 125 kHz...

Страница 12: ...r programming the locking system Information can be exchanged between the Keyvi management software and locking units using the service unit The information includes for example authorizations events...

Страница 13: ...r of the locking system If this key is held in front of a locking system component then the respective component goes into service mode where it is possible for example to create or change authorisati...

Страница 14: ...CX6192 Ensure that the cabinet lock does not protrude and prevent the door from swinging freely After assembly check the function with the door open The locking lever should be tightened with a maximu...

Страница 15: ...rotation of the operating lever is determined by the position of the small screw on the mounting thread Opening by turning the operating lever to the left Opening by turning the operating lever to th...

Страница 16: ...X6192 ASSEMBLY 15 Mount the cabinet lock using the mounting nut and mounting screw Secure the locking lever and lock washer with the mounting nut locking lever Check if the cabinet lock is functioning...

Страница 17: ...6 The authorisations have to be changed first in the Keyvi management software for the individual cabinet locks or groups of cabinet locks The software consolidates these settings into tasks which the...

Страница 18: ...ne cabinet can only be used for Mifare and LEGIC versions Mode B Any system key Clex prime priority The functionality as in mode 0 applies for all the authorised Clex prime cards In addition you can l...

Страница 19: ...1 0 295 5 3 Configuring the cabinet lock Prerequisites Orders have been created in the Keyvi management software and sent to the service device or to ClexTouch Hold the service key in front of the rea...

Страница 20: ...6 2 Open close the door Wake up the cabinet lock by pressing the button Hold the authorised key in front of the reading unit till the green LED starts glowing Open or close the cabinet by turning the...

Страница 21: ...n LEDs start glowing Time changeover toggling On Long loud beep green LEDs start glowing Time changeover toggling Off Long loud beep red LEDs start glowing Reset Long low beep all the LEDs are switche...

Страница 22: ...hen inserting the battery Open the battery compartment of the cabinet lock with the battery replacement tool For this purpose press the tool into the opening below the cabinet lock until the battery c...

Страница 23: ...ror 5 long beeps 2 short beeps RTC fault clock 5 long beeps 3 short beeps Internal error unhandled interrupt 5 long beeps 4 short beeps Internal error bus conflict 5 long beeps 5 short beeps Internal...

Страница 24: ...sal Do not dispose of the cabinet lock with domestic waste Disposal should be in accordance with the European Directive 2002 96 EC at a collection point for electrical waste Defective or used batterie...

Страница 25: ...ata carrier that contains the authorization information This can for example be an ISO card or a chip The key is sometimes also known as transponder Service unit Data can be exchanged between a PC hav...

Отзывы: