manualshive.com logo in svg
background image

(P/N) 731.018 Rev H 12/14 • © copyright 2008-2014   

 

Kaba Mas LLC

page 1 of 11

The ComboGard Pro Lock has three states of operation: 

Factory 

Default, Manual Setup, and Active. ComboGard Pro locks are 
shipped from LA GARD in Factory Default state without Users or 
features enabled. 
Factory Default: The Lock must be in the Factory Default state 
to be programmed by the PC software. 
Factory mode functions as follows: 
• 

1 key – When pressed, will open the Lock. 

• 

0 key – When pressed, prompts the ComboGard Pro Setup 

  software to send the configuration settings to the Lock.
 

OR if pressed and held, places the Lock into Manual Setup. 

•  All other keys perform no function. 

Manual Setup: The Lock can be configured using the 
keypad only. 

Active: To activate the Lock and freeze the configuration, the 
Manager combination MUST be changed. 

PROGRAMMABLE LOCK FEATURES 

MODES (Multiple Modes may be selected.)
• 

Silent Alarm (Alarm Box Required - P/N 2789NC) 

  If enabled, this option will send a signal to an outside alarm 
  system through the LA GARD Alarm Box. 

•  Dual Mode
  If enabled, two combinations will be required to operate 
  the Lock.
  The Manager and one additional User must be active.

•  Time Delay Override
  If enabled, User 9 can override delay period.
  User 9 must be active. 

EXTERNAL SIGNALS (Alarm Box Required - P/N 2789NC. Only 
one External Signal type may be selected.)
 
An external input signal to the Alarm Box will either disable the 
Lock from opening, override the time delay, or enable the remote 
override depending on the selection programmed for External 
Signals.
•  External Signal disables Lock opening with valid combination.
• 

OR External Signal overrides Time Delay. (This option is ONLY 

  available if enabled using Setup software.)
• 

OR External Signal enables the Remote Override. (This option 

  is ONLY available if enabled using Setup software, 

and with 

  Lock code level 39E v1.09 or higher.)

TIME DELAY  
•  Delay Period 1 - 99 minutes 
•  Open Period 1 - 19 minutes 
NOTE: If the Time Delay On is not selected, then this feature is 
inactive. This feature may be enabled later. (Refer to Manager 
Instructions 732.018.)

COMBINATION LENGTH 
A combination length from six (6) to nine (9) digits may be 
selected.
NOTE: To maintain the VdS Class 2 and EN 1300 Class B 
certification when the duress alarm feature is used, a combination 
length of 7 digits or longer must be selected.

LOCK USERS 
Manager 
•  Open Lock 
•  Change Combination 
•  Enable/Disable Users 
•  Delete Users 
•  Set Time Delay Values 
•  Audit Lock 

Up to 9 Users 
•  Open Lock 
•  Change Combination

STANDARD LOCK FEATURES 

Wrong Try Penalty  
•  Entry of four (4) consecutive invalid combinations initiates a five 
  (5) minute delay penalty. 
  Lock responses during the penalty period are as follows:
    -  The LED will flash every ten (10) seconds. 
    -  If any key is pressed, the Lock will flash the LED and beep 
   three 

times.

•  Once the penalty period has ended, two (2) consecutive invalid 
  combinations will initiate another five (5) minute penalty period. 

Low Battery Warning 
•  Repeated audio/visual signals (LED flashes/beeps) during Lock 
  opening indicate the battery is low and should be 
  replaced immediately.
•  If the battery level becomes too low to safely operate the Lock, 
  pressing any key will initiate the low battery warning. 
  The battery must be replaced before the Lock will operate. 

Audit Records 
•  Lock records the last 63 events in non-volatile memory. 
•  Audit file cannot be deleted from the Lock. 
•  Only the Manager can audit the Lock.
•  ComboGard Pro auditing software and an Interface Adapter are 
  required to retrieve a Lock audit.

COMBOGARD

PRO

39E Electronic Combination Lock

SETUP INSTRUCTIONS

ComboGard Pro locks can either be configured using the ComboGard Pro Setup software or through a series of keypad commands. 
This document will cover configuring the lock using both methods. 

Содержание ComboGard Pro 39E

Страница 1: ...lable if enabled using Setup software and with Lock code level 39E v1 09 or higher TIME DELAY Delay Period 1 99 minutes Open Period 1 19 minutes NOTE If the Time Delay On is not selected then this feature is inactive This feature may be enabled later Refer to Manager Instructions 732 018 COMBINATION LENGTH A combination length from six 6 to nine 9 digits may be selected NOTE To maintain the VdS Cl...

Страница 2: ... back to factory state but the SM code remains unchanged The default code of 5 5 5 5 5 5 5 5 must be changed before the Manager default code is changed or the Super Master Reset function will be permanently lost Process is as follows Action Press and hold 0 key for 3 seconds Result Lock beeps twice and the LED remains ON throughout the entire process Action Enter default code of 5 5 5 5 5 5 5 5 Pr...

Страница 3: ...teps a Right click on My Computer b Select Manage The Computer Management window is displayed c Under System Tools select the Device Manager d From the Device Manager list select Ports COM LPT The list of communication and printer ports currently identified in the PC system will be displayed e Plug the USB or Serial Interface Adapter into an available USB port on the PC If using a USB Adapter the ...

Страница 4: ...or a Serial Adapter select the standard Serial COM Port to be used Figure 3 Select Mode s Select by placing a check mark in the desired operational Mode Silent Alarm External Signals and Time Delay Multiple modes can be selected Silent Alarm If selected a LA GARD alarm box will be required to use this feature Dual Mode If selected two combinations are required to operate the lock At least one addi...

Страница 5: ... Box required P N 2789NC By placing a check mark in the desired option select either Disable Opening Remote Time Delay Override or Remote Override Figure 7 Disable Opening Input signal to the Alarm Box will disable the opening of the lock by a valid combination Remote Time Delay Override Input signal to the Alarm Box will disable the time delay and allow the opening of the lock by any valid combin...

Страница 6: ...n is not selected this feature is inactive This feature may be enabled later by the Manager Refer to ComboGard Pro Manager Instructions 732 018 Figure 6 Figure 7 Figure 8 Install Users The Manager cannot be disabled because the Manager must be installed with a combination in order to activate the lock To install a User place a check mark in the Installed box next to the User ID When a User is sele...

Страница 7: ...4 Plug the programming cable into the audit programming port of the Entry Device Figure 10 5 Click on the Transmit button in the software Figure 11 6 Press the 0 key on the keypad to begin transmitting the configurations to the lock Figures 12 13 14 If the COM port has been incorrectly set return to the setup window Figure 2 and reset the COM port to the correct one If you do not know which COM po...

Страница 8: ... P N 731 018 Rev H 12 14 copyright 2008 2014 Kaba Mas LLC page 8 of 11 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 ...

Страница 9: ... the Manager still has the ability to change the lock configuration To complete the activation and freeze the lock s configuration the Manager combination MUST be changed Prior to changing Manager Combination SMR must be set up or it will be lost Please refer to Page 2 of this document for SMR instructions To change the Manager combination follow the steps below CAUTION Always perform this operati...

Страница 10: ...nter combination length a second time and press 0 to confirm Example setting a combination length to seven digits Enter 5 5 5 5 5 5 hold down the last number 8 7 0 7 0 6 To test enter default Manager combination 5 5 5 5 5 5 5 all fives to length of combination Lock will signal twice and lock will open NOTE If combination length is changed after Users are enrolled all Users will be deleted and must...

Страница 11: ... LOCK To complete the activation of the lock and freeze the configuration the Manager combination MUST be changed Please note SMR must be changed first or it will be lost To change the Manager combination follow the steps below CAUTION Always perform this operation with the door open 1 Enter the default Manager combination and hold down the last digit until unit double signals twice and the LED st...

Отзывы: