RODUCT DESCRIPTION

 

 

The four-eyes group is used to operate a knob cylinder only when two different 
keys are held up, out of which one should be a member of the four eyes group 
and the other should have normal authorization for the knob cylinder. Which 
group is defined as the four-eyes group can be configured for each knob 
cylinder. 
In combination with a CX6934 IDS module, the knob cylinder can be used to 
enable and disable the intrusion detection system (IDS). To do this it is necessary 
to define a group (IDS group) in the knob cylinder that is authorized to enable / 
disable the IDS. 
In addition, a firefighters group can be defined, which is always authorized to 
open the door regardless of the status of the intrusion detection system. In 
contrast to the group access rights of the fire brigade, the switching status of the 
intrusion detection system is first queried for all the other group access rights 
before granting the access right. 

3.1.2

 

Time zones 

You can restrict the locking access right in terms of time by using a time zone. 
The time restriction along with the locking authorizations are programmed in the 
key in the Clex prime system. 
The following time restrictions are possible: 

 

Total interval 

 

Day interval 

 

Weekly schedule 

 

Holidays 

 

Special time zones 

For detailed information on the different time zones, please refer to the Keyvi 
software manual. 

3.1.3

 

Automatic expiry date 

Using the automatic expiry date, it is possible to restrict the validity of a key 
regardless of the time zones applicable for the key. 
For detailed information on the automatic expiry date, please refer to the Keyvi 
software manual. 

3.1.4

 

Radio network 

If a corresponding radio network is installed in the building, then the knob 
cylinder CX616x can be integrated with this network. The following functions can 
be then be executed via radio: 

 

Programming access rights 

 

Changing access rights 

 

Configuring time zones / timer circuits 

 

Reading event log 

 

Engaging the knob cylinder (for the duration defined by locking time) 

 

Viewing battery and maintenance messages 

 

Reading the battery value 

 

FW update 

3.1.5

 

Key feedback 

Even for knob cylinders operated offline, there is an option to send the battery 
status of the knob cylinders to the Keyvi management software. To do this, the 
battery status of the 16 most recently operated locking units is stored on the key. 

Four-Eyes-Group 

Intrusion detection 

system (IDS) group 

 

 

Содержание CX6162

Страница 1: ...CX6162 66 Clex prime Compact electronic knob cylinder Operating and assembly manual...

Страница 2: ...ergstra e 2 4 97297 Waldb ttelbrunn Germany Tel 49 931 40672 0 E Mail contact UundZ de http www UundZ de This operating and assembly manual is copyright protected The information contained this manual...

Страница 3: ...anagement accessories 13 4 Assembly 14 4 1 General assembly instructions 14 4 2 Assembly 14 5 Commissioning 15 5 1 Initial commissioning 15 5 2 Managing the locking system 16 5 3 Configuring the knob...

Страница 4: ...ruptions or hazards such as non access to injured personnel malfunctions property damage or other damages resulting from non compliance with this operating and assembly manual or incorrectly configure...

Страница 5: ...locks The applicable regulations should be followed The CX616x should not be used if the housing or the electronics is damaged Changes or retrofits to the product are not allowed The knob module shou...

Страница 6: ...ing No cabling required Can be combined with other systems for example Clex private Versions for MIFARE and LEGIC Transponder can be supplied 3 1 1 Authorisations There are up to 296 groups in the Cle...

Страница 7: ...tions are programmed in the key in the Clex prime system The following time restrictions are possible Total interval Day interval Weekly schedule Holidays Special time zones For detailed information o...

Страница 8: ...the knob cylinder is accompanied with flashing of red light 5 times and 5 short audible signals The battery needs to be changed If an authorized key is held in front of the reading unit then the red L...

Страница 9: ...Phase 3 Manipulation Toggle off Toggle On Unknown position Service mode Radio diagnosis Automatic wake up off Wireless opening not OK Wireless opening OK The following information are recorded for ev...

Страница 10: ...d scope of supply 3 2 1 CX6162 1 Grub screw 5 Battery 2 Mechanical knob 6 Electronic knob 3 Fixing screw 7 Knob cover 4 Cylinder casing 3 2 2 CX6166 1 Fixing screw 4 Electronic knob 2 Half cylinder ca...

Страница 11: ...T DESCRIPTION 10 3 3 Variants Different variants of the electronic knob cylinder are available for selection For indoor or outdoor use Various cylinder casing lengths Basic version without date time a...

Страница 12: ...the mechanical knob 20 0mm Diameter of the mechanical knob 29 0mm Transponder Version 1 MIFARE MIFARE Classic MIFARE DESFire Active transponder 868MHz Version 2 LEGIC LEGIC prime LEGIC advant MIFARE D...

Страница 13: ...SCRIPTION 12 3 4 3 Dimensions 3 5 Standards The electronic knob cylinder CX616x meets the following standards EN 15684 2013 being prepared EN 60529 2014 being prepared A B 44 3 20 0 29 0 31 4 A 10 44...

Страница 14: ...elevant data can be sent directly to all the locking system components of Clex prime that are provided with a radio chip 3 6 4 CX6520 Programming station The programming station is an optional additio...

Страница 15: ...always check if the components can move freely After assembly check the function with the door open 4 2 Assembly Insert the cylinder housing along with the electronic knob into the lock Tighten the f...

Страница 16: ...e are two options of changing over to the normal operating mode Option 1 Turn the knob a few times to wake up the reading unit till an LED starts glowing Hold up the key in front of the reading unit o...

Страница 17: ...age 18 Wake up sensitivity see chapter 6 1 Automatic wake up page 17 Expiry date of a key see chapter 3 1 3 Automatic expiry date page 6 Radio response of the knob cylinder wake on radio mode The auth...

Страница 18: ...lic objects in the surroundings without reading a key then automatic wake up is disabled In this case the knob cylinder has to be woken up manually Turn the knob a few times to wake up the reading uni...

Страница 19: ...g the door handle in the unlocked state The time duration for which the knob cylinder remains engaged can be configured 1 to 15 seconds the default value is 5 seconds After successful authorization en...

Страница 20: ...g Key authorised Green LEDs start glowing Timer circuit toggling On Long loud beep green LEDs start glowing Timer circuit toggling Off Long loud beep red LEDs start glowing Reset Long low beep all the...

Страница 21: ...ry CAUTION Danger of injury caused by improper use Do not charge open or heat the battery Always replace discharged batteries with new batteries Pay attention to the correct polarity when inserting th...

Страница 22: ...er as far as it goes onto the knob so that the marked spot on the knob cover aligns with the protruding plastic part on the knob The knob cover has to be inserted such that only the rubber seal is vis...

Страница 23: ...g CAUTION Damage to the sealing ring caused by improper handling Do not use any sharp objects and do not stretch the sealing ring more than what is required for mounting Precondition Knob cover is rem...

Страница 24: ...rror 5 long beeps 2 short beeps RTC fault clock 5 long beeps 3 short beeps Internal error unhandled interrupt 5 long beeps 4 short beeps Internal error bus conflict 5 long beeps 5 short beeps Internal...

Страница 25: ...POSAL 24 9 Disassembly and Disposal 9 1 Disassembly Loosen the Allen screw of the mechanical knob and remove the mechanical knob from the cylinder Remove the fixing screw Remove the cylinder body and...

Страница 26: ...should be in accordance with the European Directive 2002 96 EC at a collection point for electrical waste Defective or used batteries should be recycled in accordance with the European Directive 2006...

Страница 27: ...contains the authorization information This can for example be an ISO card or a chip The key is sometimes also known as transponder Service unit Data can be exchanged between a PC having the Keyvi man...

Отзывы: