CX6162/66
O
PERATION
18
6.2
Opening and locking the door.
Hold the authorised key in front of the reading unit till the green LED starts
glowing.
The knob module is now engaged and the door can be locked and unlocked
by turning the electronic knob module.
The door can be opened using the door handle in the unlocked state.
The time duration for which the knob cylinder remains engaged can be
configured (1 to 15 seconds, the default value is 5 seconds). After successful
authorization (engaging) at the knob, the engagement time countdown starts.
6.3
Toggling the knob cylinder
Hold the key with toggle authorisation for a period of two locking cycles in
front of the reading unit.
Depending on the initial state, the knob cylinder either engages or disengages
permanently.