background image

digital

 

 

 

by Lenz Elektronik GmbH

 

 

 

Mini-Lokdecoder

 73 300, 73 310, 73 340 73 406, 73 416

 

 

Description

 

 

This manual describes in detail the entire range of functions of your new locomotive decoder. In order to enjoy it as much as 
possible, please read the instructions carefully and completely.

 

 

This locomotive decoder is a small, very powerful multi-protocol decoder. It can be used in DCC, Motorola and Selectrix digital 
systems. It also runs in analog mode with DC voltage. The respective operating mode is automatically detected, but it can also 
be set manually.

 

 

The decoder works with a frequency of 18.75 kHz and is therefore suitable not only for direct current, but also for

 

 

Bell armature motors (e.g., Faulhaber, Maxon, Escap) up to a continuous current consumption of 0.8 A

 

 

Motor currents up to 2 A are well tolerated.

 

 

The  decoder  is  RailCom®

  and  RailCom  Plus®

  capable  and  masters  both  ABC  braking  and  ABC  slow-speed  driving.  The  engine 

characteristic curve  is  set via the minimum, medium and maximum speed (simple characteristic curve), or via the extended 
characteristic curve with individual settings for 28 speed steps.

 

 

The decoder has two direction-dependent lighting outputs, as well as two additional special function outputs (not 73115). Its manoeuvring 
gear with extended low-speed range and the three possible starting and braking decelerations can be switched via function keys. Ideal for 
use  in American  locomotive models  is  the  possibility  to  activate  special, typical  American  light  effects  (Mars  Light,  Gyra Light,  Strobe, 
etc.).

 

The  assignment  of  switching  tasks  such  as  lighting,  special  function  outputs  (not  73115),  shunting  and  switchable  driving, 
braking deceleration (ABV) can be freely assigned  to the function keys F0 - F12 of the  digital control center (small function 
mapping). In addition, the decoder also supports extended function mapping. In the extended function mapping, simultaneous 
switching  on  or  off  of  several  outputs  is  possible  depending  on  linked  conditions  (F-keys,  direction  of  travel,  loco  stands  / 
moves) with a function key assignment F0 - F44.

 

 

The  decoder  can  be  programmed  via  all  Intelliboxes,  DCC  and  Märklin  controllers.  All  CVs  can  be  programmed  with  all 
devices.  To  facilitate  programming,  especially  for extended  function mapping,  the  programming  software  "Lok-Tool"  can  be 
used,  which  is  included  with  the  digital  programming  and  test  station  "DigiTest"  from  Uhlenbrock.  This  software  is  also 
available for free download on our website www.uhlenbrock.de.

 

 

As  a  further  special  feature,  the  decoder  can  be  updated  via  the  digital  programming  and  test  station  "DigiTest"  from 
Uhlenbrock. It can even remain in the closed vehicle. Even the installation of locomotive sounds on a connected IntelliSound 4 
module can take place in this constellation in the installed state.

 

 

IMPORTANT

: All information

 about

 the function outputs A1 & A2 in the user manual do not apply to the decoder 73115 with 

6-pin NEM 651 interface.

 

 

Analog operation with DC voltage

 

 

The locomotive decoder is suitable for analog operation with DC voltage, which is detected 
independently. 

ATTENTION:

 Operation with AC voltage will destroy the decoder!

 

 

NOTE: In DC mode, your vehicle will only start at a higher voltage (throttle further turned up) than you might have been used 
to in operation with analog vehicles.

 

 

Function outputs in analog mode

 

 

It is possible to set the decoder so that the function keys F0 - F12, as assigned in the function mapping, can also be switched 
on  in  analog  mode.  For  this  purpose,  the  CVs  13  &  14  must  first  be  programmed  with  a  digital  control  center.  The 
corresponding values can be found in the CV table.

 

 

Motor control

 

 

The motor control preset in the decoder is ideal for most motor types. If the driving behavior of  your vehicle does not meet 
your expectations, because it jerks, for example, at low speed, you can  change  this standard setting of the  engine  control. 
Two control types are available for adjusting the motor control.

 

 

1. PID Regler 

 

2. SX two-point controller 

 

Within the CV51, the first three bits can be used to define whether a controller should be active, if yes, which controller should be active 
and whether a fixed or variable period is used (see Configuration CVs -> Table CV51, Bits 0 - 2).

 

CV51

 

 

Bit0 -> 0 = knob off, 1 = knob on

 

 

Bit1 -> 0 = PID-Regler, 1 = SX-Regler

 

 

Bit2 -> 0 = fixed period duration according to CV53, 1 = dynamic period duration CV53, 200, 201, 202

 

 

CV53 -> Period of motor control in 100µs steps

 

 

CV54 -> PID: P content

 

 

CV55 -> PID: I-component

 

 

CV56 -> PID: D content

 

 

CV57 -> PID: Regler Offset

 

 

CV58 -> Measuring gap for EMF measurement in 100µs steps

 

 

Speed-dependent (dynamic) period of the motor control

 CV200 minimum speed 

step (0-255) up to which the period duration = CV53 is set CV201 maximum speed 
step (0-255) from which the period duration = CV202 is set CV202 maximum period 
duration in 100µs steps

 

 

For  the  variable  controller period,  the  period  duration  for  internal  speed  steps  smaller  than  CV200  is  set  to  the  value  from 
CV53.  Up  to  the  speed  step  according  to  CV201,  the  period duration  is  linearly  changed  up  to  the  value  in  CV202. For  all 
driving levels above CV201, the period is set to the value of CV202.

 

 

The engine control can be adapted to the locomotive via the CVs 53 to 58 and 200 to 202.

 

 

In order for the decoder to use the dynamic period duration, it must be switched on via the CV51 bit 2.

 

 

Instructions for changing the controller parameters P, I, D:

 

 

Before changing the controller parameters, make sure that

 

 

1. The transmission is smooth running 

 

2. The collector of the motor is not smeared 

 

3. No capacitors from motor to chassis (ground) are present 

 

Once these three points have been processed, you can start with the settings according to the following pattern.

 

 

) Enable PID control, bit 1 in CV51 = 0

 

 

) Set PID control offset CV57 = 0

 

 

) With the factory setting of the decoder CV2, 5 and 6 (min, max and medium speed) preset the motor control via CV54, 55 

and 56.

 

Содержание 74 320

Страница 1: ...ng track 8 Power consumption right red when the programming mode of the control panel is called up When reading or programming very small currents usually flow which do not damage the decoder in the event of a short circuit red orange blue yellow weiß green grey black Connection of special functions An additional special function such as smoke generator automatic coupling or a cab lighting can be ...

Страница 2: ... de de_DE service download konformitätserklärung index htm Our advantages for you If you have any questions we are here for you Internet FAQs can be found at www uhlenbrock de E Mail service uhlenbrock de Hotline 49 0 2045 8583 27 The times can be found on our service page QR code Premium hotline 49 0 900 1858327 If it is urgent Chargeable 98cent min dt Festnetz mobile considerably more expensive ...

Страница 3: ...ction outputs A1 A2 in the user manual do not apply to the decoder 73115 with 6 pin NEM 651 interface Analog operation with DC voltage The locomotive decoder is suitable for analog operation with DC voltage which is detected independently ATTENTION Operation with AC voltage will destroy the decoder NOTE In DC mode your vehicle will only start at a higher voltage throttle further turned up than you...

Страница 4: ...steps via CV 2 CV 5 and CV 6 0 Use characteristic curve from CV 67 94 16 5 Kurze Adresse CV 1 Register 1 0 Long address CV 17 and 18 32 Bit Konfiguration CV 50 Wert 0 Do not use Motorola 2nd address 0 Motorola 2nd address use 1 1 Do not use Motorola 3rd address 0 Motorola 3rd address use 2 2 Do not replace light outputs 0 Replace light outputs 4 3 Frequency light A1 and A2 156Hz 0 Frequency light ...

Страница 5: ... 1st edition of this description remains valid If braking is initiated with a constant braking distance the decoder only responds to driving commands again when the locomotive has come to a standstill This process can be interrupted by switching on the shunting gear Determination of the maximum speed of the model locomotive In the decoder program the CV of the maximum speed to the maximum possible...

Страница 6: ... If such an output is switched on via a wireless button it is automatically switched off in the desired direction of travel CV113 2 A1 forward from CV113 4 A2 forward from CV113 8 A3 forward from CV113 16 A4 forward from CV114 2 A1 backwards from CV114 4 A2 backwards from CV114 8 A3 backwards from CV114 16 A4 backwards from A combination sum of the individual values is possible Simple and advanced...

Страница 7: ...switch off automatically after an adjustable time without having to switch off the function key Furthermore the decoder can ensure that the coupling is only actuated for a short switch on moment with an adjustable high PWM to safely lift the coupling After this moment less energy is required to keep the clutch up This lower PWM as well as the required holding time are also adjustable If the used c...

Страница 8: ...everal outputs starting and braking delays shunting second dimming of the function outputs SUSI as logic level output transfer of the function keys F22 to F28 to SUSI as well as the setting of the CROSS bit possible These functions can be switched on or off depending on linked conditions such as function keys F0 to F44 direction of travel of the locomotive as well as loco stands or moves These com...

Страница 9: ...ula 256 line 1 16 bytes Formula 256 line 17 16 bytes The bit structure and the values to be programmed accordingly in the CVs are comparable to the configuration CVs of the decoder This means that there is a fixed value per bit set If the bit is not set the value for this bit remains 0 Bit Wert Bit 0 1 Bit 1 2 Bit 2 4 Bit 3 8 Bit 4 16 Bit 5 32 Bit 6 64 Bit 7 128 Summe 255 The values for the indivi...

Страница 10: ... CV 272 1 To facilitate programming especially for extended function mapping the programming software Lok Tool can be used which is included with the digital programming and test station DigiTest from Uhlenbrock This software is also available for free download on our website www uhlenbrock de Second dimming of light and function outputs The light and function outputs can be set to an alternative ...

Страница 11: ...From decoder software version 23 CV7 3rd edition 25 02 19 ...

Страница 12: ...decoders Programming with a Märklin control unit eg 6021 With a Märklin control panel all CVs can be programmed but not read out The decoder can be put into programming mode in two ways a and b depending on the control panel and then programmed Switch off and on the control panel Set control panel to Motorola old 6021 DIP 2 off switch control panel off and on Select address of decoder and turn on ...

Страница 13: ... 255 255 Bit 0 0 DC analog operation direct current off 0 Bit 0 1 DC analog operation direct current on 1 Bit 2 0 Data format DCC from 0 Bit 2 1 Data format DCC a 4 Bit 3 0 Data format Motorola from 0 Bit 3 1 Data format Motorola a 8 Bit 4 0 Data format Selectrix from 0 Bit 4 1 Data format Selectrix a 16 13 Activate function keys in analog mode 0 255 0 bit 0 7 F1 to F8 bit 0 function off bit 1 fun...

Страница 14: ...ght A1 and A2 156Hz 0 Bit 3 1 Frequency light A1 and A2 24KHz 8 Bit 4 0 SUSI SUSI 0 Bit 4 1 SUSI A3 A4 output function mapping table 16 51 Decoder Konfiguration 2 Wert 0 135 3 131 Bit 0 0 Motor control from 0 Bit 0 1 Motor control a 1 Bit 1 0 Motor control PID Controller 0 Bit 1 1 Motor control SX controller 2 Bit 2 0 no dynamic period of motor control 0 Bit 2 1 Dynamic period of motor control 4 B...

Страница 15: ...e value 200ms 16 240 131 Dynamic smoke generator control load threshold 0 255 5 132 Dynamic smoke generator control PWM normal operation 0 63 16 133 Dynamic smoke generator control PWM idle stand 0 63 2 134 Dynamic smoke generator control start up time in 100ms steps 0 255 30 135 Shunting Ango automatic uncoupling drive speed 0 off 0 255 0 136 Shunting ango pressing time T1 100ms 0 255 10 137 Shun...

Страница 16: ...164 Servo control Servo 2 position 2 function key on 0 255 200 ...

Страница 17: ...bes Switching on effect of light and function outputs A1 A2 0 7 0 bit 0 2 A0 to A2 Bit 0 effect off bit 1 effect on 189 Neon tubes turn on effect flash time value 5ms 0 255 20 190 Neon tubes turn on effect maximum flash count 0 255 20 200 Motor control speed dependent period 0 255 10 minimum speed up to which the period duration CV53 is set 201 maximum speed from which the period CV202 is set 0 25...

Страница 18: ...8 16 24 32 48 63 63 63 63 48 32 24 16 8 3 0 63 each until 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 63 each 320 3 8 16 24 32 48 63 63 63 63 48 32 24 16 8 3 0 63 each 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 63 each 321 3 8 16 24 32 48 63 63 63 63 48 32 24 16 8 3 0 63 each until 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 63 each 384 3 8 11 14 22 28 32 32 32 32 28 22 14 11 8 3 0 63 each 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 63...

Отзывы: