There are 2 connections required - the fibre port and the mains supply. The fibre
port should be connected first. Connect and secure the fibre optic connector into
the front of the unit, and secure using the M5 locking screw.

Plug the mains plug into the electrical supply socket. Switch on the power, the LED
indicator will illuminate, and the light source and the twinkle wheel will start up
automatically. If no light is produced consult the troubleshooting section.

NOTE:  THESE  LIGHT  SOURCES ARE NOT MAINS DIMMABLE

.

MOUNTING

If using the metal mounting plate proceed as follows:

STEP 1
Remove the rubber feet from the bottom of the Light Source

STEP 2
Push fit three of the expansion fittings into the holes vacated by the feet as shown –
DO NOT fit an expansion fitting into the foot hole at the rear below the push buttons

STEP 3
Place the mounting plate on the base as shown and push the remaining expansion
fitting through the plate into the hole that does not have one fitted. Fit all four
screws and tighten. Do not over tighten

The luminaire can now be fixed securely to the mounting surface.

Содержание MIC100PT-3

Страница 1: ...PC 6 UFO MIC100PCT 3 UFO MIC100PCT 4 UFO MIC100PCT 6 Please read this manual fully before installing operating or performing maintenance on the light source unit Light Source User Guide Issue 3 Revise...

Страница 2: ...E APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED 2 TYPE Y ATTACHMENT If the external flexible cable or cord of this lumin...

Страница 3: ...powered by a 12V Power Supply Unit or 12V Constant Voltage Driver Remove the PSU driver from its box The driver caters for UK European other mains supplies using the relevant power cord supplied Conn...

Страница 4: ...consult the troubleshooting section NOTE THESE LIGHT SOURCES ARE NOT MAINS DIMMABLE MOUNTING If using the metal mounting plate proceed as follows STEP 1 Remove the rubber feet from the bottom of the L...

Страница 5: ...MAINTENANCE Date Maintenance Undertaken Please note that a record of all maintenance MUST be kept in the table below indicating what maintenance was undertaken and when This must be DATED for warranty...

Страница 6: ...icator is still illuminated LED array failure Replace LED unit Unit is not twinkling Motor speed push button at stop Press button to start motor Twinkle wheel motor failure Replace Unit Poor light out...