S9500-30XS Hardware Installation Guide | 19
LED Condition
Equipment Status
FAN
Off
System (X86 &BMC) no boot
Solid Green
All FAN modules work well
Blinking Yellow
One or more FAN module(s) fail or no FAN module present
PWR
Off
No power or in shutdown mode.
Solid Green
System power good & BMC heating done
Blinking Green
System power good & BMC is heating
Solid Yellow
System power good but BMC heating fail
Blinking Yellow
System power fail
PSU FRU LED
LED Condition
Equipment Status
Off
No DC power to all PSUs
Flashing Red
No DC power to this PSU
Flashing Green
DC present, only standby output on. Poor contact
Green
PSU DC output ON and OK
Red
PSU failure.
Flashing between
Green and Red
Warning. Working condition not satisfied. Please check the voltage,
electric current, and temperature.
Fan FRU LED
LED Condition
Equipment Status
Off
Main board 3.3V power fail or Fan is not present.
Solid Green
Fan is present and interrupt de-assert
Blinking Green
N/A
Solid Yellow
N/A
Blinking Yellow
Fan is present but interrupt assert.
Management port LED
LED Condition
Equipment Status
Left LED
Off
1G no link
Solid Green
1G link-up
Blinking Green
1G TX/RX activity
Right LED
Off
No activity
Solid Amber
10M/100M link-up
Blinking Amber
10M/100M TX/RX activity