RECOMMENDED PRACTICES AND WARNINGS 

United Electric Controls Company recommends careful consideration 
of the following factors when specifying and installing UE pressure and 
temperature units. Before installing a unit, the Installation and Maintenance 
instructions provided with unit must be read and understood. 

•  To  avoid  damaging  unit,  proof  pressure  and  maximum  temperature  limits 

stated  in  literature  and  on  nameplates  must  never  be  exceeded,  even  by 
surges  in  the  system.  Operation  of  the  unit  up  to  maximum  pressure  or 
temperature  is  acceptable  on  a  limited  basis  (e.g.,  start-up,  testing)  but 
continuous operation must be restricted to the designated adjustable range. 
Excessive cycling at maximum pressure or temperature limits could reduce 
sensor life.

•  A back-up unit is necessary for applications where damage to a primary 

unit  could  endanger  life,  limb  or  property.  A  high  or  low  limit  switch  is 
necessary  for  applications  where  a  dangerous  runaway  condition  could 
result.

•  The  adjustable  range  must  be  selected  so  that  incorrect,  inadvertent  or 

malicious  setting  at  any  range  point  cannot  result  in  an  unsafe  system  
condition.  

•  Install  unit  where  shock,  vibration  and  ambient  temperature  fluctuations 

will not damage unit or affect operation. Orient unit so that moisture does 
not  enter  the  enclosure  via  the  electrical  connection.  When  appropriate, 
this entry point should be sealed to prevent moisture entry.

•  Unit  must  not  be  altered  or  modified  after  shipment.  Consult  UE  if 

modification is necessary.  

•  Monitor operation to observe warning signs of possible damage to unit, 

such as drift in set point or faulty display.  Check unit immediately.

•  Preventative  maintenance  and  periodic  testing  is  necessary  for  critical 

applications where damage could endanger property or  personnel.

•  For all applications, a factory set unit should be tested before use.
•  Electrical  ratings  stated  in  literature  and  on  nameplate  must  not  be 

exceeded. Overload on a switch can cause damage, even on the first cycle.  
Wire unit according to local and national electrical codes, using wire size 
recommended in installation sheet.

•  Do not mount unit in ambient temp. exceeding published limits.

LIMITED WARRANTY

Seller  warrants  that  the  product  hereby  purchased  is,  upon  delivery,  free  from 
defects in material and workmanship and that any such product which is found 
to be defective in such workmanship or material will be repaired or replaced by 
Seller  (Ex-works,  Factory,  Watertown,  Massachusetts.  INCOTERMS);  provided, 
however, that this warranty applies only to equipment found to be so defective 
within  a  period  of  24  months  from  the  date  of  manufacture  by  the  Seller  (36 
months for the Spectra 12 and One Series products; 18 months for Temperature 
Sensors).  Seller  shall  not  be  obligated  under  this  warranty  for  alleged  defects 
which  examination  discloses  are  due  to  tampering,  misuse,  neglect,  improper 
storage,  and  in  any  case  where  products  are  disassembled  by  anyone  other 
than authorized Seller’s representatives. EXCEPT FOR THE LIMITED WARRANTY 
OF  REPAIR  AND  REPLACEMENT  STATED  ABOVE,  SELLER  DISCLAIMS  ALL 
WARRANTIES  WHATSOEVER  WITH  RESPECT  TO  THE  PRODUCT,  INCLUDING 
ALL  IMPLIED  WARRANTIES  OF  MERCHANTABILITY  OR  FITNESS  FOR  ANY 
PARTICULAR PURPOSE. 

LIMITATION OF SELLER’S LIAbILITY

Seller’s  liability  to  Buyer  for  any  loss  or  claim,  including  liability  incurred  in 
connection  with  (i)  breach  of  any  warranty  whatsoever,  expressed  or  implied, 
(ii)  a  breach  of  contract,  (iii)  a  negligent  act  or  acts  (or  negligent  failure  to 
act) committed by Seller, or (iv) an act for which strict liability will be inputted 
to  seller,  is  limited  to  the  “limited  warranty”  of  repair  and/or  replacement  as 
so stated in our warranty of product.  In no event shall the Seller be liable for 
any  special,  indirect,  consequential  or  other  damages  of  a  like  general  nature, 
including, without limitation, loss of profits or production, or loss or expenses of 
any nature incurred by the buyer or any third party.
UE specifications subject to change without notice.

180 Dexter Avenue, P.o. box 9143
Watertown, MA  02471-9143   uSA
Telephone: 617 926-1000    fax: 617 926-2568
http://www.ueonline.com

Содержание 120 Series

Страница 1: ... or both can be used during installation A 3 4 explosion proof plug is provided for properly sealing the unused conduit opening thE explosion proof plug must be properly sealed during product installation GENERAL Misuse of this product may cause explosion and personal injury These instructions must be thoroughly read and understood before unit is installed This equipment is suitable for use in Cla...

Страница 2: ... engage cover O ring Types J120 J120K H121 H121K H122 H122K H122P Mount controls vertically pressure connection facing down see Figure 1a or horizontally see Figure 1b Control may be surface mounted via the four 1 4 screw holes on the enclosure or mounting bracket It can also be mounted directly to a rigid pipe using the pressure connection Controls with Breather Drain Option M450 Type J120 J120K ...

Страница 3: ...ront switch is set by turning the internal calibrating screw to the right for lower set point and turning to the left for higher set point When not set together the front switch should never be set higher than the rear switch Turning the external knob will increase or decrease both switch settings simultaneously without disturbing their relationship Controls with Options Option 1519 and other mode...

Страница 4: ...71 174 521 525 531 535 and 540 548 Turn hex IN an additional 1 1 2 flats from this point This will provide a 5 9 mil gap Models 680 701 705 356 376 612 616 270 274 Turn hex IN 3 flats from this point approximately 1 2 turn This will provide a 14 16 mil gap Models 183 189 190 194 483 489 490 494 565 567 Turn hex IN 1 flat from this point This will provide a 4 7 mil gap CONTACT FACTORY FOR ASSISTANC...

Страница 5: ...35 0 1 2 530 535 8 84 224 5 1 2 550 552 8 81 223 8 1 4 551 553 555 8 34 211 8 1 4 560 564 7 53 191 3 2 Sanitary 565 567 7 53 191 3 1 1 2 Sanitary 612 616 7 88 200 2 1 4 680 8 13 206 5 1 4 701 705 15622 15834 15839 7 44 189 0 1 4 Differential Pressure 36 39 147 157 367 7 59 192 8 1 4 S147B S157B 7 59 192 8 1 2 455 457 559 8 44 214 4 1 4 540 543 9 34 237 2 1 8 544 548 9 41 239 0 1 8 Types H121 H122 ...

Страница 6: ...sonnel For all applications a factory set unit should be tested before use Electrical ratings stated in literature and on nameplate must not be exceeded Overload on a switch can cause damage even on the first cycle Wire unit according to local and national electrical codes using wire size recommended in installation sheet Do not mount unit in ambient temp exceeding published limits LIMITED WARRANT...

Отзывы: