IMP120-14

www.ueonline.com

Internal Set Point Adjustment

Types J120, J120K

External Set Point Adjustment

Types H121, H122, H121K, H122K, H122P

Models 126-164

Models S126B-S164B

Models 171-174

Models 188-194, 

488-494

Models 183-186, 

483-486

Pressure

Surface Mounting kit

6361-704

Types J120, J120K

Dimension A

Models

Inches 

mm

NPT

Pressure

126-164

7.25

184.2

1/4

S126b-S164b

7.63

193.8

1/2

171-174

8.72

221.5

1/2

183-186, 483-486

8.41

213.6

1/2

188-189, 488-489

7.47

189.7

1/2

190-194, 490-494

7.44

189.0

1/2

270-274

8.13

206.5

1/4

358-376

8.09

205.5

1/4

450, 452

8.81

223.8

1/4

451, 453, 454

8.06

204.7

1/4

520-525

9.25

235.0

1/2

530-535

8.84

224.5

1/2

550, 552

8.81

223.8

1/4

551, 553-555

8.34

211.8

1/4

560-564

7.53

191.3

2” Sanitary

565-567

7.53

191.3

1-1/2” Sanitary

612, 616

7.88

200.2

1/4

680

8.13

206.5

1/4

701-705, 15622, 
15834-15839

7.44

189.0

1/4

Differential Pressure

36-39, 147-157, 367

7.59

192.8

1/4

S147b-S157b

7.59

192.8

1/2

455-457, 559

8.44

214.4

1/4

540-543

9.34

237.2

1/8

544-548

9.41

239.0

1/8

Types H121, H122, H121K, H122K, H122P

Dimension A

Models

Inches 

mm

NPT

Pressure

126-164

8.09

205.5

1/4

S126b-S164b

8.50

215.9

1/2

270-274

7.88

200.2

1/4

358-376

7.81

194.4

1/4

450, 452

9.69

246.1

1/4

453, 454

8.94

227.1

1/4

550, 552

9.75

247.7

1/4

553-555

9.31

236.5

1/4

612, 614, 15875

8.75

222.3

1/4

701-705

8.31

211.1

1/4

Differential Pressure

147-157

8.44

214.4

1/4

S147b-S157b

8.44

214.4

1/2

456-457, 559

9.31

236.5

1/4

Dimensions

Содержание 120 Series

Страница 1: ... or both can be used during installation A 3 4 explosion proof plug is provided for properly sealing the unused conduit opening thE explosion proof plug must be properly sealed during product installation GENERAL Misuse of this product may cause explosion and personal injury These instructions must be thoroughly read and understood before unit is installed This equipment is suitable for use in Cla...

Страница 2: ... engage cover O ring Types J120 J120K H121 H121K H122 H122K H122P Mount controls vertically pressure connection facing down see Figure 1a or horizontally see Figure 1b Control may be surface mounted via the four 1 4 screw holes on the enclosure or mounting bracket It can also be mounted directly to a rigid pipe using the pressure connection Controls with Breather Drain Option M450 Type J120 J120K ...

Страница 3: ...ront switch is set by turning the internal calibrating screw to the right for lower set point and turning to the left for higher set point When not set together the front switch should never be set higher than the rear switch Turning the external knob will increase or decrease both switch settings simultaneously without disturbing their relationship Controls with Options Option 1519 and other mode...

Страница 4: ...71 174 521 525 531 535 and 540 548 Turn hex IN an additional 1 1 2 flats from this point This will provide a 5 9 mil gap Models 680 701 705 356 376 612 616 270 274 Turn hex IN 3 flats from this point approximately 1 2 turn This will provide a 14 16 mil gap Models 183 189 190 194 483 489 490 494 565 567 Turn hex IN 1 flat from this point This will provide a 4 7 mil gap CONTACT FACTORY FOR ASSISTANC...

Страница 5: ...35 0 1 2 530 535 8 84 224 5 1 2 550 552 8 81 223 8 1 4 551 553 555 8 34 211 8 1 4 560 564 7 53 191 3 2 Sanitary 565 567 7 53 191 3 1 1 2 Sanitary 612 616 7 88 200 2 1 4 680 8 13 206 5 1 4 701 705 15622 15834 15839 7 44 189 0 1 4 Differential Pressure 36 39 147 157 367 7 59 192 8 1 4 S147B S157B 7 59 192 8 1 2 455 457 559 8 44 214 4 1 4 540 543 9 34 237 2 1 8 544 548 9 41 239 0 1 8 Types H121 H122 ...

Страница 6: ...sonnel For all applications a factory set unit should be tested before use Electrical ratings stated in literature and on nameplate must not be exceeded Overload on a switch can cause damage even on the first cycle Wire unit according to local and national electrical codes using wire size recommended in installation sheet Do not mount unit in ambient temp exceeding published limits LIMITED WARRANT...

Отзывы: