UE SYSTEMS INC. 

THE ULTRAPROBE 2000 

MANUAL

 

Содержание ULTRAPROBE 2000

Страница 1: ...1 UE SYSTEMS INC THE ULTRAPROBE 2000 MANUAL...

Страница 2: ...tery Level Light Sensitivity Selection Head Set Jack Trigger Switch Frequency Adjust Dial Meter Mode Selection Recharge Jack Charging the Ultraprobe Pistol Charging the WTG 2 Ultrasonic Tone Generator...

Страница 3: ...ce The instrument provides testing capability ranging from leak detection to mechanical analysis It is a testing laboratory that fits in the palm of your hand BASIC COMPONENTS OF YOUR KIT Headphones B...

Страница 4: ...CTION NUMERICALLY CALIBRATED DIAL The increments on this dial allow for 500 individual set points There are 2 sets of numbers The outer window reflects the whole digit and reads from 0 to 10 The insid...

Страница 5: ...is an extremely narrow band response that when used with the contact stethoscope module reduces most stray unwanted pipe and mechanical noises In the scanning mode it provides for extreme sensitivity...

Страница 6: ...low level indicator light illuminates IMMEDIATELY recharge the Ultraprobe If the instrument is not used for a week or more recharge it If the Ultraprobe is not used for a few days it can be used with...

Страница 7: ...m the gross to the fine If there is too much ultrasound in the area reduce the sensitivity place the RUBBER FOCUSING PROBE described below over the scanning module and proceed to follow the test sound...

Страница 8: ...th the sensitivity level at or near maximum Occasionally when in this situation stray ultrasound may interfere with clear reception and be confusing If this occurs place the RUBBER FOCUSING PROBE over...

Страница 9: ...ack on the metered pistol housing and place the headphones over your ears The UE DHC 2HH Hard Hat Headphones are specifically designed for hard hat use WTG 1 WARBLE TONE GENERATOR STANDARD The WTG 1 T...

Страница 10: ...lever Move this change lever to the middle of the lock in a way that allows it to hook behind the change notch drawing 1 Set your personal combination turning the dials to the desired combination i e...

Страница 11: ...ed fault conditions is incapable under the test conditions prescribed in article 500 of the national Electrical Code NFPA 70 of causing ignition of a specified mixture of flammable or combustible mate...

Страница 12: ...shielding 5 1 2 long chrome plated brass probe tip conically shaped for uniform surface contact Probe tip is interchangeable Stethoscope extension kit 3 piece segmented to increase stethoscope contact...

Страница 13: ...the equipment with your hands or fingers Be sure to use appropriate lockout procedures when attempting repairs Be careful with loose hanging parts such as the wrist strap or headphone cord when inspec...

Страница 14: ...14 Need further support Want information regarding products or training CONTACT UE Systems Inc 14 Hayes Street Elmsford NY 10523 USA T 914 592 1220 E info uesystems com W www uesystems com...