SAFETY ADVISORY. PLEASE READ BEFORE USING 
YOUR INTRUMENT.  
 

WARNING! 

Improper use of your ultrasonic detector may result in death or serious injury. Observe all safety 
precautions. Do not attempt to make any repairs or adjustments while the equipment is 
operating. Be sure to turn off and LOCK OUT all electrical and mechanical sources before 
performing any corrective maintenance. Always refer to local guidelines for appropriate lockout 
and maintenance procedures. 

SAFETY PRECAUTION. 

Although your ultrasonic instrument is intended to be used while 

equipment is operating, the close proximity of hot piping, electrical equipment and rotating parts 
are all potentially hazardous to the user. Be sure to use extreme caution when using your 
instrument around energized equipment. Avoid direct contact with hot pipes or parts, any moving 
parts or electrical connections. Do not attempt to check findings by touching the equipment with 
your hands or fingers. Be sure to use appropriate lockout procedures when attempting repairs. 

Be careful with loose hanging parts such as the wrist strap or headphone cord when inspecting 
near moving mechanical devices since they may get caught. Don't touch moving parts with the 
contact probe. This may not only damage the part but cause personal injury as well. 

When inspecting electrical equipment, use caution. High voltage equipment can cause death or 
severe injury. Do not touch live electrical equipment with your instrument. Use the rubber 
focusing probe with the scanning module. Consult with your safety director before entering the 
area and follow all safety procedures. In high voltage areas, keep the instrument close to your 
body by keeping your elbows bent. Use recommended protective clothing. Do not get close to 
equipment. Your detector will locate problems at a distance. 

When working around high temperature piping, use caution. Use protective clothing and do not 
attempt to touch any piping or equipment while it is hot. Consult with your safety director before 
entering the area.

 

 

Содержание ULTRAPROBE 2000

Страница 1: ...1 UE SYSTEMS INC THE ULTRAPROBE 2000 MANUAL...

Страница 2: ...tery Level Light Sensitivity Selection Head Set Jack Trigger Switch Frequency Adjust Dial Meter Mode Selection Recharge Jack Charging the Ultraprobe Pistol Charging the WTG 2 Ultrasonic Tone Generator...

Страница 3: ...ce The instrument provides testing capability ranging from leak detection to mechanical analysis It is a testing laboratory that fits in the palm of your hand BASIC COMPONENTS OF YOUR KIT Headphones B...

Страница 4: ...CTION NUMERICALLY CALIBRATED DIAL The increments on this dial allow for 500 individual set points There are 2 sets of numbers The outer window reflects the whole digit and reads from 0 to 10 The insid...

Страница 5: ...is an extremely narrow band response that when used with the contact stethoscope module reduces most stray unwanted pipe and mechanical noises In the scanning mode it provides for extreme sensitivity...

Страница 6: ...low level indicator light illuminates IMMEDIATELY recharge the Ultraprobe If the instrument is not used for a week or more recharge it If the Ultraprobe is not used for a few days it can be used with...

Страница 7: ...m the gross to the fine If there is too much ultrasound in the area reduce the sensitivity place the RUBBER FOCUSING PROBE described below over the scanning module and proceed to follow the test sound...

Страница 8: ...th the sensitivity level at or near maximum Occasionally when in this situation stray ultrasound may interfere with clear reception and be confusing If this occurs place the RUBBER FOCUSING PROBE over...

Страница 9: ...ack on the metered pistol housing and place the headphones over your ears The UE DHC 2HH Hard Hat Headphones are specifically designed for hard hat use WTG 1 WARBLE TONE GENERATOR STANDARD The WTG 1 T...

Страница 10: ...lever Move this change lever to the middle of the lock in a way that allows it to hook behind the change notch drawing 1 Set your personal combination turning the dials to the desired combination i e...

Страница 11: ...ed fault conditions is incapable under the test conditions prescribed in article 500 of the national Electrical Code NFPA 70 of causing ignition of a specified mixture of flammable or combustible mate...

Страница 12: ...shielding 5 1 2 long chrome plated brass probe tip conically shaped for uniform surface contact Probe tip is interchangeable Stethoscope extension kit 3 piece segmented to increase stethoscope contact...

Страница 13: ...the equipment with your hands or fingers Be sure to use appropriate lockout procedures when attempting repairs Be careful with loose hanging parts such as the wrist strap or headphone cord when inspec...

Страница 14: ...14 Need further support Want information regarding products or training CONTACT UE Systems Inc 14 Hayes Street Elmsford NY 10523 USA T 914 592 1220 E info uesystems com W www uesystems com...

Отзывы: