Doc. 85860I - Rev. 22/10/2020
USER MANUAL
USER MANUAL
EN
EN
Drw. / Dis. 33942/h
14/54
7.3 Calibration
All the electrical connections, including the main power supply, must reach the control unit through the dedicated cover.
For that purpose, proceed as follows:
7
Remove the fixing holes from cover “
E
”.
Drill holes on the cover according to the
amount of cables to be connected.
Reposition cover “
E
” on the box equipped
with gasket “
F
”.
Each cable must be inserted into the control unit through a dedicated cable gland (not included).
E
8
9
E
F
Connect the power supply cable to the dedicated terminal on
the power supply unit.
Connect the black cable to the battery.
In this phase, the control unit is powered so the most careful attention should be paid.
The calibration must be carried out only when the control unit is on its final configuration.
Once the installation has been completed and all connections (including those related to the
batteries and mains power supply) have been formed, the yellow LED will stay lit on the con
-
trol unit (red and greed LEDs off), to indicate that calibration of the test circuitry on the motor
outputs is required. Check that the control unit and the motors are working correctly, and then
push the CAL button on the board. If no errors, faults, or emergencies are detected, the control
unit will go into STANDBY mode, which is indicated by only the green LED switching on and
staying on.
Содержание C-SV 20A
Страница 2: ......
Страница 25: ...Doc 85860I Rev 22 10 2020 USER MANUAL USER MANUAL EN EN Drw Dis 33942 h 25 54 NOTES ...
Страница 26: ......
Страница 55: ......