background image

VERA-P1 series - Data Sheet 

UBX-17004377 - R04

 

Confidential 

Pin Definition 

 

 

Page 13 of 28

 

No. 

Name 

Pin 
type 

Power 
domain 

Description 

B51 

NC 

Leave unconnected 

B52 

GND 

Ground 

Ground 

B53 

NC 

Leave unconnected 

B54 

NC 

Leave unconnected 

B55 

NC 

Leave unconnected 

B56 

GND 

Ground 

Ground 

B57 

NC 

Leave unconnected 

B58 

NC 

Leave unconnected 

B59 

NC 

Leave unconnected 

B60 

NC 

Leave unconnected 

B61 

NC 

Leave unconnected 

B62 

NC 

Leave unconnected 

B63 

GND 

Ground 

Ground 

B64 

NC 

Leave unconnected 

B65 

NC 

Leave unconnected 

B66 

NC 

Leave unconnected 

B67 

NC 

Leave unconnected 

B68 

NC 

Leave unconnected 

B69 

NC 

Leave unconnected 

B70 

GND 

Ground 

Ground 

B71 

BOOT_2 

VIO 

Boot mode configuration 

B72 

BOOT_1 

VIO 

Boot mode configuration 

B73 

NC 

Leave unconnected 

B74 

GND 

Ground 

Ground 

B75 

NC 

Leave unconnected 

B76 

NC 

Leave unconnected 

EP 

GND 

Ground 

20 Ground/Thermal exposed pads, connect to the ground 

Table 3: VERA-P1 series pin description

 

Содержание VERA-P171

Страница 1: ...s transceiver module that enables development of electronics for Vehicle to Everything V2X communication systems The VERA P1 series includes an integrated MAC LLC Baseband processor and the required R...

Страница 2: ...es to the following products Product name Type number Firmware version PCN reference Product Status VERA P171 VERA P171 00A 00 N A N A Prototype VERA P173 VERA P173 00A 00 N A N A Prototype VERA P174...

Страница 3: ...4 3 Digital pad ratings 14 4 4 Peak current consumption 15 4 5 Current consumption 15 4 6 Radio specifications 16 5 Mechanical specifications 18 5 1 Physical dimensions 18 6 Qualification and approva...

Страница 4: ...04377 R04 Confidential Contents Page 4 of 28 8 Labeling and ordering information 25 8 1 Product labeling 25 8 2 Explanation of codes 25 8 3 Ordering codes 25 Appendix 26 Glossary 26 Related documents...

Страница 5: ...or in vehicle units OBU On Board Unit their use in V2X infrastructure RSU Road Side Unit is intended but not authorized yet The VERA P1 series modules provide superior performance compared to V2X syst...

Страница 6: ...gram of VERA P171 Figure 2 Block diagram of VERA P173 and VERA P174 1 4 Product description Model Description VERA P171 Single channel no antenna diversity one antenna VERA P173 Single channel antenna...

Страница 7: ...24 27 Mbps Antenna diversity VERA P173 VERA P174 CDD for TX and MRC for RX mode TX output power from 10 to 23 dBm Class C RX sensitivity 97 dBm at 3 Mbps Power supply 3 3 V and 5 0 V 4 W maximum Oper...

Страница 8: ...P1 series module supports an SPI interface for firmware loading booting and data communication Firmware can be loaded by the host processor while the module operates as a slave or from the FLASH memor...

Страница 9: ...VERA P1 series Data Sheet UBX 17004377 R04 Confidential Pin Definition Page 9 of 28 3 Pin Definition 3 1 Pin description Figure 3 Pin allocation top view...

Страница 10: ...Leave unconnected A15 NC Leave unconnected A16 NC Leave unconnected A17 NC Leave unconnected A18 GND Ground Ground A19 5V0_A1 Power Antenna 1 radio front end supply 4 5 to 5 5V A20 GND Ground Ground...

Страница 11: ...e unconnected A61 GND Ground Ground A62 USB_DN I O USB Bus A63 USB_DP I O USB Bus A64 USB_VBUS I USB VBUS detect input A65 GND Ground Ground A66 GND Ground Ground A67 GND Ground Ground A68 NC Leave un...

Страница 12: ...ave unconnected B21 NC Leave unconnected B22 GND Ground Ground B23 GND Ground Ground B24 GND Ground Ground B25 NC Leave unconnected B26 NC Leave unconnected B27 NC Leave unconnected B28 GND Ground Gro...

Страница 13: ...NC Leave unconnected B61 NC Leave unconnected B62 NC Leave unconnected B63 GND Ground Ground B64 NC Leave unconnected B65 NC Leave unconnected B66 NC Leave unconnected B67 NC Leave unconnected B68 NC...

Страница 14: ...re 40 95 C Table 4 Absolute maximum ratings The product is not protected against overvoltage or reversed voltages If necessary voltage spikes exceeding the power supply voltage specification given in...

Страница 15: ...00 TBD 500 500 15 dBm 700 TBD TBD TBD 10 dBm 700 TBD TBD TBD 0 dBm 700 TBD TBD TBD Table 7 Peak current consumption 4 5 Current consumption Power consumption for different operation modes TBD 6 Peak v...

Страница 16: ...er maximum operating input level 802 11p 20 dBm RSSI accuracy 802 11p Over tempearature range 2 dB Centre frequency and symbol clock tolerance 802 11p 10 ppm Transmitter spectral flatness 802 11p All...

Страница 17: ...Mbps 2 3QAM64 0 12 22 27 Mbps 3 4QAM64 1 11 20 Table 10 Adjacent channel rejection Bit rate Target ACR dB Target opt enc ACR dB VERA P1 typical ACR dB 3 Mbps 1 2BPSK 32 42 51 4 5 Mbps 3 4BPSK 31 41 4...

Страница 18: ...VERA P1 series Data Sheet UBX 17004377 R04 Confidential Mechanical specifications Page 18 of 28 5 Mechanical specifications 5 1 Physical dimensions Figure 4 Physical dimensions...

Страница 19: ...of the exposed thermal pads pattern 22 3 22 4 22 5 E3 Vertical dimension of the individual exposed thermal pad 3 9 4 0 4 1 e Pitch of the peripheral pads 1 2 BSC E1 Pitch of the individual exposed the...

Страница 20: ...s module must provide a separation distance of at least 20 cm from all persons and must not be co located or operating in conjunction with any other antenna or transmitter These limits are designed to...

Страница 21: ...countries TBD 6 2 Approved antennas VERA P173 is certified to be used with dipole antennas of up to 6 dBi peak gain Table 15 below lists an example of an approved antenna Model name Manufacturer and...

Страница 22: ...1 2 Tapes The dimensions of the tapes are specified in Figure 5 Figure 5 VERA P1 tape dimensions 7 2 Shipment storage and handling For more information regarding shipment storage and handling see the...

Страница 23: ...als and encapsulated water could lead to short circuits between neighboring pins Only a single reflow soldering process is permitted for host boards with the VERA P1 series modules The reflow profile...

Страница 24: ...e receiver Unless there is a galvanic coupling between the local GND i e the work table and the PCB GND then the first point of contact when handling the PCB must always be between the local GND and P...

Страница 25: ...17 Product Code Formats Code Meaning Example PPPP Form factor VERA TG Platform T Dominant technology For example W Wi Fi B Bluetooth G Generation P1 VV Variant based on the same platform range 00 99 7...

Страница 26: ...mission GND Ground GPIO General purpose input output IC Industry Canada LLC Logical Link Control MAC Media Access Control nACR Non adjacent channel rejection NLoS Non Line of Sight OBU On Board Unit O...

Страница 27: ...he kgom Initial release R02 5 May 2017 ddie kgom Added VERA P174 product variant and included block diagram FCC IC ID and ordering code for this variant R03 11 Sep 2017 mzes kgom ddie Updated Table 1...

Страница 28: ...ort support_ap u blox com Regional Office China Beijing Phone 86 10 68 133 545 E mail info_cn u blox com Support support_cn u blox com Regional Office China Chongqing Phone 86 23 6815 1588 E mail info...

Отзывы: