Compliance with these directives implies conformity to the following European Norms for device ESD
immunity: ESD testing standard CENELEC EN 61000-4-2 and the radio equipment standards ETSI
EN 301 489-1, ETSI EN 301 489-7, ETSI EN 301 489-24, the requirements of which are summarized
in Table 11.
The ESD immunity test is performed at the enclosure port, defined by ETSI EN 301 489-1 as the
physical boundary through which the electromagnetic field radiates. If the device implements an
integral antenna, the enclosure port is seen as all insulating and conductive surfaces housing the
device. If the device implements a removable antenna, the antenna port can be separated from the
enclosure port. The antenna port includes the antenna element and its interconnecting cable
surfaces.
The applicability of ESD immunity test to the whole device depends on the device classification as
defined by ETSI EN 301 489-1. Applicability of the ESD immunity test to the related device ports or
the related interconnecting cables to auxiliary equipment depends on device accessible interfaces
and manufacturer requirements, as defined by ETSI EN 301 489-1.
Contact discharges are performed at conductive surfaces, while air discharges are performed at
insulating surfaces. Indirect contact discharges are performed on the measurement setup horizontal
and vertical coupling planes as defined in CENELEC EN 61000-4-2.
☞
For the definition of integral antenna, removable antenna, antenna port, and the device
classification, refer to the ETSI EN 301 489-1. For the contact and air discharges definitions, refer
to CENELEC EN 61000 4-2.
Application
Category
Immunity Level
All exposed surfaces of the radio equipment and ancillary
equipment in a representative configuration
Indirect Contact Discharge
±8 kV
Table 11: Electromagnetic Compatibility ESD immunity requirements as defined by CENELEC EN 61000-4-2, ETSI EN 301
489-1, ETSI EN 301 489-7, ETSI EN 301 489-24
NORA-B1 is manufactured with attention to specific standards that minimize the occurrence of ESD
events; the highly automated process complies with IEC61340-5-1 (STM5.2-1999 Class M1 devices)
standard, and therefore designers should implement proper measures to protect any pin that may be
exposed to the end user from ESD events.
Compliance with the standard protection level specified in EN61000-4-2 can be achieved by including
ESD protections in parallel to the line, close to areas accessible by the end user.