10

 

SETUP Z-WAVE NETWORK 

10.1

 

Check Custos BVS Status: 

-

 

Before Adding into Z-Wave Network, you have to make sure Custos BVS is in Standalone mode. 

-

 

By default, Custos BVS does not belong to any Z-Wave Network and color indicator is keeping in Yellow Blinking.   

*If not, please perform “Factory Default Reset - refer to 10.4” or “Remove from Z-Wave Network – refer to 10.3”   

 

10.2

 

Add Custos BVS into Z-Wave Network: 

Custos BVS supports Security 2 Command Class while a Security S2 enabled controller is needed. SmartStart or Classis 
Inclusion, you can use either of these modes. It supports 

-

 

SmartStart: 

Custos BVS comes with DSK Code, end-user by scanning the QR code or entering first 5 digits during inclusion is 

processing that shows in DSK Code label.   

-

 

Classic Inclusion: 

Set your Z-Wave Gateway into Inclusion mode / Add device. 

i.

 

Start: Short press Touch Sense Button 3 times.

 

ii.

 

Processing: Yellow LED and 

short beep sound keeping continue. For security inclusion support, you may need to entering 

first 5 digit that show on QR Code label, please refer to the instructions of central controller. 

iii.

 

Success: Green LED on 1 second with 2 short beep sounds.

 

iv.

 

The LED indication changes to Green LED slow blinking from Yellow LED blinking. 

 

10.3

 

Remove Custos BVS from Z-Wave Network: 

Set your Z-Wave Gateway into Exclusion mode / Remove device. 

i.

 

Start: Short press Touch Sense Button 3 times. 

ii.

 

Processing: Yellow LED and 

short beep sound keeping continue. 

iii.

 

Success: Green LED on 1 second with 2 short beep sounds. 

iv.

 

The LED indication Changes to Yellow LED blinking.     

Содержание Custos BVS-ZW Series

Страница 1: ...BVS ZWx User Manual Ubitech Ltd Version 0 9 4 Page 1 Custos Ball Valve Servo Technology for Humanity...

Страница 2: ...8 Support Command Class in NIF 3 9 Configuration CC 4 WHAT INSIDE IN THE BOX 5 UNDERSTANDING CUSTOS BVS 5 1 Connectors Interfaces 6 KEY INDICATORS BEHVIOR 6 1 Touch Sense Button 6 2 Visual Indicator 6...

Страница 3: ...E Operation 11 5 Resume OPEN CLOSE Operation 12 WATER LEAK ALARM 12 1 Water Leak Detection Alarm 12 2 Water Leak Alarm Cancellation 13 TEMPERATURE SENSOR REPORT 13 1 Temperature Report 14 APPENDIX 14...

Страница 4: ...Certificated product works within any same Z Wave network 1 2 Custos BVS Cusots Ball Valve Servo Custos BVS is capable for outdoor deployment for control water valve open close It also support auto c...

Страница 5: ...8 80 2 2 Hardware Specifications Parameter Value Z Wave Module ZGM130S037HGN1 Z Wave RF Distance 40m Indoor 140m Outdoor Region Frequency US 908 4 916MHz FCC CFR47 Part 15 249 EU 868 42 869 85MHz Mot...

Страница 6: ...itch Generic Device Type Switch Binary Specific Device Type Valve Open Close Security Class Non Security S0 S2 Unauthenticated and S2 Authenticated SmartStart Support After powering on SmartStart is a...

Страница 7: ...PE_GENERIC_VALVE_OPEN_CLOSE User Icon Type 0x1500 ICON_TYPE_GENERIC_VALVE_OPEN_CLOSE 3 2 Version CC Parameter Value Z Wave Protocol Library Type 0x03 Z Wave Protocol Version 0x07 Z Wave Protocol Sub V...

Страница 8: ...pport Event Water Valve 0x0F Valve operation status 0x01 Event Parameter 1 byte 0x00 Valve does not let the water run through 0x01 Valve lets the water run through 3 5 Indicator CC Parameter Value Ind...

Страница 9: ...eport 0x0F 0x01 Valve operation l 0x00 VALVE CLOSED OFF Valve does not let the water run through l 0x01 VALVE OPEN ON Valve lets the water run through 2 Water Valve 3 Basic Set 0x00 Doesn t let the wa...

Страница 10: ...3 Support Support Support Support NOTIFICATION 8 Support Support Support Support VERSION 3 Support Support Support Support MANUFACTURER_SPECIFIC 2 Support Support Support Support DEVICE_RESET_LOCALLY...

Страница 11: ...0xFF 0x02 Basic OFF 0x00 0x01 0x13 19 Name Association Group 2 Reports 0x00 SET Value Info Configure Valve SET Value when receives 0x00 1 Byte 0x00 Disable 0x01 Basic ON 0xFF 0x02 Basic OFF 0x00 0x02...

Страница 12: ...nfo Configure Freeze Recover Report Value 2 Bytes 0x0000 0x00FF Set C value 0x0100 0x01FF Set F value 0x0004 4 C 0x0128 40 F 0x2A 42 Name Freeze Detection Valve Control Forbidden Info Enable Disable v...

Страница 13: ...x00 Disable 0x01 Enable 0x01 0x42 66 Name LED Brightness Level Info Configure LED brightness level 1 Byte 0x00 0x63 0x50 0x43 67 Name Touch Keylock Info Disable Enable Touch Keylock function 1 Byte 0x...

Страница 14: ...2020 Ubitech Ltd Version 0 9 4 Page 14 4 WHAT INSIDE IN THE BOX Standard Custos BVS package comes with below items A Custos BVS Main Unit x 1 B AC DC Adaptor x 1 AC 110 220V to DC 12V 1A C Local Leak...

Страница 15: ...se to adjust Fork widths c Sound Indicator Buzzer i Fork Mount on valve handler max 1 width d Temperature Sensor Built in Temperature Sensor j Clamp Mount on water pipe Max 1 1 4 diameter e QR Code Pr...

Страница 16: ...R 6 1 Touch Sense Button Short Press One click comes with one short beep sound Long Hold Press and holding the key Come with 1 x short beep per second 6 2 Visual Indicator 3 Colors LED GREEN YELLOW RE...

Страница 17: ...Handle Refer to Figure A Make sure the Knob and Valve Handle are facing on same side Refer to Figure B Tighten Clamps while holding down the Custos BVS Unplug the Dust Cover and plug Local Water Senso...

Страница 18: ...such as remote control associate with other Z Wave end devices 8 3 Water Valve Support OPEN CLOSE PAUSE RESUME during OPEN CLOSE operation Auto calibration position of valve handle Only support opera...

Страница 19: ...any key event excepting Touch Sense Button Keylock Disable function Refer to 8 2 i Start Long hold Touch Sense Button 3 seconds then short click 3 times ii Process Yellow LED on 1 second then Red LED...

Страница 20: ...the QR code or entering first 5 digits during inclusion is processing that shows in DSK Code label Classic Inclusion Set your Z Wave Gateway into Inclusion mode Add device i Start Short press Touch S...

Страница 21: ...all setting to Factory Default Setting i Start Long hold Touch Sense Button for 10 seconds then short click 5 times ii Processing Yellow LED ON 1 second then wait 2 5 seconds iii Success Green LED on...

Страница 22: ...N position and let water run through the pipe i Start Short click Touch Sense Button 1 time ii Processing Water Valve turning to OPEN position Green LED blinking LED and short beep sound keep continue...

Страница 23: ...rsion 0 9 4 Page 23 11 5 Resume OPEN CLOSE Operation Resume only take effect during Pause operation i Start Short click Touch Sense Button once ii Finished Valve resume to operation Continue to Openin...

Страница 24: ...r Leak Alarm RED LED fast blinking Fast beep sound ii CLOSE Water Valve automatically iii Send out Water Alarm Notification to Z Wave Gateway Only support in Mesh Network Mode iv Water Valve keeps in...

Страница 25: ...Ltd Version 0 9 4 Page 25 13 Temperature Sensor 13 1 Temperature Report By default Custos BVS will send report to Gateway automatically in 1 C or 1 8 F change of ambient temperature Custos will send...

Страница 26: ...node from Z Wave Network 14 2 System Event Status Event Detail LED Buzzer System Ready BVS is Ready to operate after power on or reset Green LED ON 2 seconds 2 beep sounds Standalone mode heartbeat S...

Страница 27: ...andalone Network Z Wave Network 1 SmartStart Re power up the BVS unit Support Not Support 2 Classic Inclusion Add into Z Wave Mesh Network 3 Support Not Support 3 Exclusion Remove from Z Wave Network...

Страница 28: ...LED ON 1 second Short beep x 2 Next status Green LED slow blinking EXCLUSION Start EXCLUSION Click 3 times Green LED ON 1 second 1 Pulse sound Processing Yellow LED keep blinking Keep short beep Succ...

Страница 29: ...ED slow blinking Next status In Standard Mode Yellow LED slow blinking PAUSE Operation Start PAUSE Only available during Open Close operation Click 1 time Yellow LED ON 1 second Red LED ON 1 second 1...

Страница 30: ...k Alarm RED LED fast blinking Fast beep sound Processing Close Water Valve automatically RED LED fast blinking Fast beep sound Leak Alarm Cancellation Alarm Cancellation Long hold 2 seconds Green LED...

Страница 31: ...BVS ZWx User Manual Date 02 APR 2020 Ubitech Ltd Version 0 9 4 Page 31 Contact us if you have any questions Website http www ubitech hk BVS Z Wave...

Отзывы: