BVS-ZWx User Manual
Date:02-APR-2020
Ubitech Ltd.
Version: 0.9.4
Page: 9
3.7
Association Group Info (AGI)
Association
Group
Name
Node
Count
Function
1
Lifeline
5
-
Device Reset Locally Notification
-
Basic Report
-
Binary Switch Report
-
Indicator Report
-
Sensor Multilevel Report – Temperature “Auto report based on Configuration Parameter 0x22 Setting.”
-
Heat Alarm Notification Report (0x04)
-
0x00 = State idle
-
0x02 = Overheat – no location support
-
0x06 = Underheat – no location support
-
Water Alarm Notification Report (0x05)
-
0x00 = State idle
-
0x02 = Water leak detected – no location support
-
Water Valve Notification Report (0x0F)
-
0x01 = Valve operation
l
0x00 = VALVE CLOSED/OFF (Valve does not let the water run through.)
l
0x01 = VALVE OPEN/ON (Valve lets the water run through)
2
Water Valve
3
-
Basic Set
-
0x00 = Doesn’t let the water run through (Based on Configuration Parameter 0x12 Setting)
-
0xFF = Let the water run through (Based on Configuration Parameter 0x13 Setting)
3
Water Leak
3
-
Basic Set
-
0x00 = IDEL / CANCEL (Based on Configuration Parameter 0x31 Setting)
-
0xFF = TRIGGERED (Based on Configuration Parameter 0x32 Setting)
4
Overheat
3
-
Basic Set
-
0x00 = IDEL / CANCEL (Based on Configuration Parameter 0x27 Setting)
-
0xFF = TRIGGERED (Based on Configuration Parameter 0x26 Setting)
5
Underheat
3
-
Basic Set
-
0x00 = IDEL / CANCEL (Based on Configuration Parameter 0x2C Setting)
-
0xFF = TRIGGERED (Based on Configuration Parameter 0x2B Setting)