Chapter 2: Installation
Introduction
Installation Requirements
• CAT5/6 cable
• Phillips screwdriver
• Drill and drill bit (6 mm for wall-mounting or 3 mm for
ceiling-mounting)
• Optional: Drywall or keyhole saw (to cut 25 mm hole for
Ethernet cable feed)
Instructions
Proceed to the hardware instructions for your UniFi AP
model:
•
UniFi AP-PRO
The instructions are below.
•
UniFi AP-AC
Go to
“Hardware Installation of the
UniFi AP-AC” on page 8
for instructions.
After you install the hardware, proceed to
“Software
Installation” on page 10
.
Hardware Installation of the UniFi
AP-PRO
The UniFi AP-PRO can be mounted to the wall or ceiling.
Perform the steps for the appropriate installation:
Wall Mount
1. Position the
Mounting Bracket
at the desired location
on the wall with the cable feed slot pointed towards
the floor.
2. Use a pencil to mark the three holes on the wall. Use a
6 mm drill bit to drill the holes.
Top
Optional 25 mm Hole for Ethernet
Cable Feed through Wall
3. Follow the instruction for your Ethernet cable feed:
• If your Ethernet cable feeds through the wall, cut or
drill a circle that is approximately 25 mm in size and
lines up with the cable feed slot.
• If your Ethernet cable feeds along the wall, remove the
Plug
on the side.
4. Insert the
M3x20 Screw Anchors
into the 6 mm holes.
Secure the
Mounting Bracket
to the wall by inserting
the
M2.9x20 Screws
into the anchors.
5. Connect the Ethernet cable to the
Main/48V
port
on
the UniFi AP-PRO.
6. Align the notch on the UniFi AP-PRO with the notch on
the
Mounting Bracket.