8
Chapter 2: Installation
airFiber
™
User Guide
Ubiquiti Networks, Inc.
5. Attach a ground wire by performing the following
steps:
a. Remove the nut from the
Ground Bonding Point
.
b. Attach a ground wire (min. 8 AWG or 10 mm
2
) to the
lug and replace the nut to secure the wire.
c. Secure the other end of the ground wire to the pole,
tower, or grounding bar.
Note:
The grounding wire should be as short as
possible and no longer than 1 meter in length.
Connecting Ethernet
1. Press down on the indicator arrows and slide the
Port
Cover
off.
2. Connect a TOUGHCable or other outdoor, shielded
CAT5e/6 cable to the
DATA
port.
3. Create a strain relief for the Ethernet cable by feeding
a cable tie through the tie slot under the cable. Then
wrap the cable tie around the cable and tighten.
4. Connect the other end of the Ethernet cable from the
DATA
port to the Ethernet port labeled
POE
on the
PoE
Adapter
.
5. Connect an Ethernet cable from your LAN to the
Ethernet port labeled
LAN
on the