EN: CAUTION: 

Be sure to depressurize the transformer before starting 

installation.

ES: PRECAUCIÓN: Asegúrese de despresurizar el transformador antes de 

iniciar la instalación.

EN:

 Remove the pressure/temperature 

sensor and tee fitting from the box. 
ES: Retire de la caja el sensor de presión 

/ temperatura y la conexión T (Fitting).

E. Install the Pressure/Temperature Sensor* 

  Instalar el sensor de presión / temperatura* 

EN:

 

NOTE

: For Kits without a 

Pressure/Temperature Sensor, skip 

to section F. Attach the Secondary 

R Cable.

ES: NOTA:

 

Si el kit no incluye el 

sensor de presión / temperatura, 

salte a la sección E. Conectar 

el arnés del sensor R 

secundario.

EN:

 Remove the pressure relief valve 

from the transformer.

ES: Retire la válvula de alivio de presión 

del transformador.

EN:

 Remove any old sealant from the 

pressure relief valve and apply 3-4 

turns of the included Teflon tape to the 

threads of the pressure relief valve. 

ES: Retire cualquier sellador viejo de 

la válvula de alivio de presión y aplique 

3-4 vueltas de la cinta de teflón incluida 

sobre las roscas de la válvula de alivio de 

presión.

EN:

 Screw the pressure relief valve into 

the female opening opposite the male 

thread on the tee fitting until hand-

tightened. Once hand-tightened, use a 

wrench to tighten 2-3 full turns more. 

ES: Atornille la válvula de alivio de 

presión en la abertura hembra opuesta a 

la rosca macho de la conexión T (Fitting) 

apretándola a mano. Una vez apretada a 

mano, use una llave inglesa para apretar 

2-3 vueltas completas más.

EN:

 

NOTE:

 With the threads 

pointing toward you, be sure to 

wrap the Teflon tape clockwise 

around the threads.

ES: NOTA: Con el lado de la rosca 

apuntando hacia usted, asegúrese 

de envolver con cinta de teflón en 

el sentido de las manecillas del 

reloj alrededor de la rosca.

Содержание ubigrid DTM+

Страница 1: ...ansformador Monof sico Tipo Pedestal EN CAUTION Always follow your organization s safety guidelines and procedures ES PRECAUCI N Siga siempre las pautas y procedimientos de seguridad de su organizaci...

Страница 2: ...UbiGrid DTM Installation Manual Single Phase Pole Mounted Transformer Manual de Instalaci n de UbiGrid DTM Transformador Poste Monof sico Tools needed for installation Herramientas para la instalaci n...

Страница 3: ...or Unit Sensor del DTM Waterproof Cap Tapa Impermeable EN CAUTION Always follow your organization s safety guidelines and procedures ES PRECAUCI N Siga siempre las pautas y procedimientos de seguridad...

Страница 4: ...ing lug on the side closest to the pressure relief valve near the top of the tank ES Antes de fijar el DTM identifique el rea de colocaci n El DTM colocarse a media distancia entre los secundarios y e...

Страница 5: ...re the DTM is mounted securely and all magnets have contact with the transformer tank ES Aseg rese de que el DTM est colocado correctamente y de que todos los imanes tengan contacto con el tanque del...

Страница 6: ...und it If the transformer has two primary bushings mount the Rogowski coil around the H1 bushing ES La bobina Rogowski es colocada alrededor de la boquilla primaria del transformador Si el transformad...

Страница 7: ...the tabs on the connector ES Coloque la tapa impermeable en el conector de pines expuesto alineando las ranuras de la tapa con las pesta as del conector EN NOTE Once installation of the primary Rogows...

Страница 8: ...Atornille la v lvula de alivio de presi n en la rosca del elemento hembra opuesta a la rosca macho de la conexi n T Fitting apret ndola a mano Una vez apretada a mano use una llave inglesa para apret...

Страница 9: ...d Once hand tightened use a wrench to tighten 2 3 full turns more Stop when the opening on the tee fitting points downward ES Instale el ensamble de la conexi n T en la abertura de la v lvula de alivi...

Страница 10: ...in connector marked with the corresponding yellow ring and two dots ES En el DTM retire el tap n antipolvo amarillo del conector de pines marcado con el correspondiente anillo amarillo y dos puntos E...

Страница 11: ...ver to slide the red locking piece upward until it clicks under the tab on the cable connector Gently tug the cable connector to ensure it is connected ES Una vez conectado al sensor de presi n temper...

Страница 12: ...l tanque del transformador Mount the Secondary Rogowski Coils Instalar las bobinas Rogowski secundarias 9 EN The black line 1 and red line 2 secondary potential wires have matching Rogowski coils moun...

Страница 13: ...N NOTE The connector of the Rogowski coil should sit either at the hinge or the ratchet tab of the secondary Rogowski coil Not in the top and bottom pockets ES NOTA El conector de la bobina Rogowski d...

Страница 14: ...ki holder may touch the rim of the transformer lid on smaller transformer tank sizes pushing forward the edge of the secondary Rogowski holder This positioning is acceptable Rotating the hinge of the...

Страница 15: ...tado Attach the Secondary Potential Cables Conectar los cables de potencial secundarios 5 EN The secondary potential cable has three wires Black line 1 White neutral Red line 2 ES El arn s de potencia...

Страница 16: ...restantes del arn s de potencial secundario 8 EN Screw the nut until the components are properly tightened on the terminal ES Atornille la tuerca hasta que los componentes se aprieten correctamente e...

Страница 17: ...s 3 4 20mm Stainless Steel Hole Punch or Step Drill Bit Punz n de acero inoxidable de 3 4 20 mm o broca de perforaci n escalonada Deburring Tool Herramienta de rebabado Standard Screwdriver Destornill...

Страница 18: ...de Antena External Antenna Antena Externa XL Zip Ties Cintas de Cable XL Grease Packet Paquete de Grasa EN CAUTION Always follow your organization s safety guidelines and procedures ES PRECAUCI N Siga...

Страница 19: ...e to the top of the transformer lid as possible ES NOTA La posici n de la antena externa se puede ajustar a la izquierda o a la derecha para evitar cualquier marca en la cara del transformador mientra...

Страница 20: ...ue la superficie exterior de la tapa est completamente limpia y seca antes de adherir la antena 9 EN Use the provided antenna cable clips to fasten the external antenna cable along the inside center o...

Страница 21: ...of the DTM sensor unit ES Retire el tap n negro de los conectores en la parte posterior del sensor DTM 2 EN Match the color and label marking of the blue and orange external antenna cable connectors t...

Страница 22: ...a del tanque del transformador aseg rese de que el indicador LED en la parte frontal del DTM apunte hacia la cavidad interna de la tapa del transformador una vez colocado EN NOTE Clean the mounting ar...

Страница 23: ...ble Conectar el Arn s del Sensor Rogowski Primario 1 EN If there is no primary Rogowski cable then skip to Step 13 Attach the Waterproof Cap Otherwise continue to Step 2 Connect the Cable Harness ES E...

Страница 24: ...ass the primary Rogowski cable from the DTM to the elbows behind the primary and service cables to ensure the primary Rogowski cable does not get tangled if the elbows are removed ES Cada uno de los c...

Страница 25: ...the elbow as it tapers angled so it is tight against the elbow and service cable ES NOTA La bobina Rogowski debe asentarse en la base del codo a cierto ngulo cuando es apretada por la cinta de modo t...

Страница 26: ...eable 13 EN Remove the waterproof cap from the box ES Retire la tapa impermeable de la caja EN NOTE For kits without a primary Rogowski cable a waterproof cap must be installed on the open pin connect...

Страница 27: ...ove any old sealant from the pressure relief valve and apply 3 4 turns of the included Teflon tape to the threads of the pressure relief valve ES Retire cualquier sellador viejo de la v lvula de alivi...

Страница 28: ...4 vueltas de la cinta de tefl n incluida sobre las roscas de la conexi n T Fitting 8 EN Screw the pressure temperature sensor into the remaining female opening on the tee fitting until hand tightened...

Страница 29: ...ese de alinear los puntos del conector del arn s con los puntos en el DTM Esto alinear las muescas del conector y los pines 4 EN Push in the secondary Rogowski cable connector Once fully inserted turn...

Страница 30: ...pressure temperature sensor lock the connector use your finger or a standard screwdriver to slide the red locking piece upward until it clicks under the tab on the connector Gently tug the cable conne...

Страница 31: ...cable con el color correspondiente de la marca de la bobina Rogowski consulte la secci n F Conectar el arn s de potencial secundario Conectar los cables de potencial secundarios EN NOTE The arrow on t...

Страница 32: ...re terminal tipo paleta y la cara del transformador 15 EN Nest the Rogowski coil within the top and bottom pockets of the Rogowski holder ES Coloque la bobina Rogowski dentro de los espacios superior...

Страница 33: ...dedor de la boquilla y la bobina Rogowski con los cables colgando libremente Connect the Cable Harness Conectar el arn s al sensor DTM 1 EN Remove the secondary potential cable from the box The second...

Страница 34: ...OTE When attaching the secondary potential cable wires be sure to match the wire color with the corresponding Rogowski color marking see Section E Attach the Secondary Rogowski Cable Mount the Rogowsk...

Страница 35: ...ighten the set screw onto the cable ES Inserte el extremo pelado del cable de potencial secundario en la primera abertura del perno y apriete el tornillo de ajuste sobre el cable 13 EN Repeat Steps 11...

Страница 36: ...te de patente Aprobado para uso p blico 2072 IR December 2022 www ubicquia com H Installation Complete Instalaci n Completa 1 EN Be sure to complete the installation of the DTM sensor unit in the UbiG...

Отзывы: