UBIHUB TYPICAL SPECIFICATIONS 

  

Power

 

Operating Temperature:

  -40° C to 50° C

Input Voltage:

  100-480 VAC

Max Current: 

 1.5A

Max Power:

  95W

Frequency:

  50/60 Hz

Power Metering

  ANSI C12.20, class 0.5

Max Load Power

 1200W

Product Characteristics 

Weight

  4.5kg  /  9.92 lb

Dimensions

  386mm x 208mm x 70mm

Warranty

  5 Years

Certifications

Safety

  ETL US  

UL 62368

FCC

  Part 15 Subpart C,

Part 15 Subpart B, Class B

Part 15 Subpart E 

Ingress Level

  IP65

Impact Rating  IK07

Vibration

  ANSI C136.31

Installation Characteristics 

Mounting

  Cobra head luminaire mount 

2 3/8 inch pole 

Cobra head luminaire mount 

1.25 inch pole

Operating Humidity

  Up to 90%

Wind Survivability

  Up to 241km/h (150 mi/h)

Altitude

  Max 2000 m

FCC statement

This device complies with Part 15 of the FCC Rules. Operation is subject to 

the following two conditions: 

1) This device may not cause harmful interference, and
2) This device must accept any interference received, including interference

that may cause undesired operation.

Changes or modifications not expressly approved by Ubicquia, Inc. could

void the user’s authority to operate the equipment.

NOTE:

 This equipment has been tested and found to comply with the 

limits for a Class B digital device, pursuant to part 15 of the FCC Rules. 

These limits are designed to provide reasonable protection against harmful 

interference in a residential installation. This equipment generates, uses 

and can radiate radio frequency energy and , if not installed and used in 

accordance with the instructions, may cause harmful interference to radio 

communications. However, there is no guarantee that interference will 

not occur in a particular installation. If this equipment does cause harmful 

interference to radio or television reception, which can be determined by 

turning the equipment off and on, the user is encouraged to try to correct 

the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

• Connect the equipment into an outlet on a circuit different from that to

which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

RF

Antenna Type

  Passive antennas

4-in-1 MIMO, flexible PCB monopole

type antenna optimized for WiFi 6

frequencies

Antenna Gain

  Up to 6dBi

Peak Transmit Power  2.4GHz: 26dBm

(Tx port/chain +

  5GHz: 26dBm

combining gain)

  5GHz: 26dBm

Frequency bands

  ISM (2.4-2.484GHz)

U-NII-1 (5.15-5.25GHz)

U-NII-2A (5.25-5.35GHz)

U-NII-2C (5.47-5.725GHz)

U-NII-3 (5.725-5.895GHz)

LTE Module Options supported

Содержание UBH-H-AI

Страница 1: ...ding Public use approved 2058 v2 October 2021 Installation Guide 1 Product Overview 1 1 View of UbiHub parts from top Before installation please read this instructional guide completely and save for future reference 1 2 View of UbiHub parts from bottom ...

Страница 2: ... all items listed in the package contents ref 1 2 are included in the box If any item is missing e mail support ubicquia com or call 1 954 678 6191 Monday through Friday 9am to 5pm EST 2 3 Remove the mounting clamp from foam insert and unwrap the protective film Caution DO NOT remove the UbiHub from the box yet 3 Preinstall Clamp 3 2 Mounting Clamp The mounting clamp has inserts available to fit 1...

Страница 3: ...ide the clamp along the housing rails and hand tighten into position for now NOTE If clamp placement was premeasured or if installing multiple units on the same luminaire type set the clamp position using the reference dimensions on both the housing and clamp then tighten all adjustment bolts to 40 in lbs torque 3 3 OPTIONAL Measure the distance from the NEMA socket to the closest point on the pol...

Страница 4: ...ottom clamp insert The inserts should be placed into the corresponding location in the clamp ensuring a complete fit They should not be loose after install Move on when the clamp inserts are firmly in place 4 1 Attach the provided grounding cable to the UbiHub housing using the grounding screw with a standard screwdriver or 5 16 socket Note the location for the safety tether attachment WARNING Ubi...

Страница 5: ...ed to the unit by a cable Caution Take care not to swing slam or knock the camera during installation The camera should be placed atop the unit during install whenever possible Make sure clamp is open with the swivel locking nut up out of the way before installing on the luminaire 5 3 Attach a safety tether to both UbiHub and the lift using the tether ring on the UbiHub If your luminaire has a pho...

Страница 6: ...gned with the pole 6 6 Adjust the clamp vertically as necessary to ensure the device is parallel with the bottom of the luminaire to ensure there is no undue stress or strain on the NEMA socket 6 5 Close the clamp around the pole by rotating the clamp latch upwards and securing with the swivel locking nut Use 1 2 socket to tighten the locking nut to 40 in lbs torque B Pull the inside grey section ...

Страница 7: ...ed grounded and secured firmly in place before moving on 7 Grounding Cable Installation 6 8 Remove tether from unit NOTE Remove all protective packaging material from the camera prior to installation 6 10 Tighten the camera top screw to 15 in lbs torque using the 3 16 Hex bit driver CAUTION The unit must be grounded in accordance with the local codes or regulations defined by the local inspector T...

Страница 8: ...op light sensor 8 Installing Photocell Optional 8 3 Installation of the UbiHub is now complete Make sure UbiHub and all elements are connected and secured firmly in place 8 2 Insert the photocell into the NEMA connector on the top of the UbiHub and twist clockwise until locked in place CAUTION The UbiHub does not need a photocell to function but should always have something installed in the NEMA N...

Страница 9: ...pment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may...

Страница 10: ...d For example safety gloves device tether warning labels flash lamp helmet and or work clothes etc In the process of installation please ensure the weather is suitable for outdoor high power electrical work If possible the installer should avoid installing in the rain or allowing the NEMA to get wet WARNING The product is required to be installed and to be connected to mains power by a skilled or ...

Отзывы: