7

TECHNOCAL SUPPORT

The UbiBot team is glad to hear your voice of our profucts and services.
For any questions or suggestions, please feel free to create a ticket in the UbiBot app. Our customer services 
representatives respond within 24 hours and often in less than an hour. You can also contact the local distribu-
tors in your contry for localized service. Please go to our website to view their contacts.

4. Deviation in temperature values after first configuration of equipment?

① The device has been configured for too long and the CPU working temperature is high;

② The device sends data too frequently, resulting in a temperature higher than 0.2~0.3℃;

③ Turn on the TVOC sensor or PM, CO2 and other sensors to collect too often will produce a certain tempera-
ture rise.

5. Only part of the data is displayed on the platform after the equipment 

has been successfully connected to the network?

Different sensors require different acquisition times. You need to click the Configuration button to upload 
manually, or wait for automatic uploading before all data is displayed.

For more frequently asked questions, please visit www.ubibot.com and go to the "Community and Documen-
tation" page.

6. The difference between CO2 and eCO2.

Carbon dioxide (chemical formula CO2) is a chemical compound made up of molecules that each have one 
carbon atom covalently double bonded to two oxygen atoms. It is found in the gas state at room temperature, 
and as the source of available carbon in the carbon cycle.

Equivalent CO2 (eCO2), also known as Global Warming Potential weighted greenhouse gas emissions (GWP), is 
a unit, that allows emissions of greenhouse gases of different strengths to be added together. eCO2 is estimat-
ed concentration of carbon dioxide calculated from known TVOC concentration. 

Содержание AQS1

Страница 1: ...Air Quality Sensor AQS1 User Manuel...

Страница 2: ...ccording to the version you purchased PACKAGE LIST INTRODUCTION Device 1 User Manual User manual 3 External antenna 2 Note The 4 prong data cable included with the device supports data transfer Using...

Страница 3: ...release the button to restore the factory state Breathing lamp can light up 4 colors green yellow orange and red Each color indicates a corresponding value range of the data collected by AQS1 The wor...

Страница 4: ...at www ubibot com setup SETUP USING THE APP FOR MOBILE NETWORK Before you set up the device on mobile data please check the APN information of the SIM card used for the UbiBot device An APN Access Poi...

Страница 5: ...online document SETUP USING PC TOOLS STEP 1 Launch the App and log in With the device switched on use the Type C USB cable provided to connect your device to the computer The PC Tools will automatical...

Страница 6: ...racy 0 3 Range 10 90 RH Accuracy 3 RH Range 26 126 kPa Range 0 500 g m3 Accuracy 10 g m3 0 100 g m3 10 100 500 g m3 Range 0 65000 ppb Range 400 65000 ppm Range 0 10000 ppm 400 2000 higher accuracy mea...

Страница 7: ...power supply of the device is properly connected Check whether the router is working properly If using the mobile data tra c provided by the SIM card inside the device you need to check whether the S...

Страница 8: ...data is displayed on the platform after the equipment has been successfully connected to the network Di erent sensors require di erent acquisition times You need to click the Con guration button to u...

Страница 9: ...man made damage to the product such as exceeding the temperature and humidity range of the equipment water caused damage including natural water such as water vapor etc fall abnormal physical force de...

Страница 10: ...V1 0 0...

Отзывы: