Manually activated fixed trigger device 

 

Used to support the care of clients in their home 

 

Compatible with Reach IP & Carer Response 

 

Single gang momentary action push button 

 

Supplied with single gang surface backbox 

 

Discreet 

 looks like a light switch   

 

5 Year Lithium battery (typical)  

 

Low battery warning 

 

Operating Temperature: +5

o

C to +40

o

C  

 

Telecare Transceiver: 869.2125MHz Class 1.5 

 

Digital Heartbeat  

 

Weight: 200 grams 

 

Dimensions: 87mm x 87mm x 40mm (HxWxD) 

 

Product Code: ZXT823

 

 

 

Positioning

 

The bogus caller alarm button should be wall mounted in 
the hallway alongside the front door or anywhere it can be 
pressed discreetly if the resident feels threatened or 
uneasy with a visitor.  

 

 

 

 

 

 

 

 

Alarm Condition

 

The bogus caller button will initiate a silent dial alarm call 

on the Reach IP unit with speech opened in “listen mode” 

only. This allows the ARC operator to listen-in and assess 
the situation before taking appropriate action. A standard 
trigger alarm will be initiated on a Carer Response.  

 

Low Battery Condition

 

A low battery condition will be reported automatically to 
the Alarm Receiving Centre (ARC). The bogus caller alarm 
should be replaced as soon as possible within 30 days.  
The bogus caller alarm can be returned to Tynetec for 
battery replacement.

  

 

Out of Range Notification

 

The Reach IP can monitor all radio peripheral devices to 
determine whether they have been damaged or removed 
from an installation. Should the Reach IP be unable to 

detect a device’s heartbeat it will automatically generate a 
“radio out of range” notification. Firstly, investigate if 
there’s a genuine reason for the alert, if not, arrange for 

the peripheral device to be replaced immediately.  

The “Radio out of range timer” can be set from 30 hours to 

99999 hours in Pulse CMP.  

“Radio supervision” can be disabled by unchecking the tick 

box associated with each peripheral device in Pulse CMP.

 

 

Maintenance

 

Test the bogus caller alarm once every month. 
Clean with a damp cloth, do not use solvents or cleaners 
on the switch plate. 

 

Disposal

 

Waste electrical products should not be disposed of with 
normal household waste. The bogus caller alarm is ideally 
suited for disposal within the waste electronic and 
electrical equipment (WEEE) recycling scheme. Please 
recycle where facilities exist.  
Check with your local authority or contact your supplier for 
recycling/disposal advice. 

 

Warning

 

The bogus caller alarm contains a Lithium battery.  
If tampered with the battery may be damaged and create a 
fire hazard.  
No attempt should be made to remove or replace the 
battery. Do not incinerate.

 

 

 

 