Installation and putting into operation
printed: 07/2023 Subject to change!
RoFryUserManual.docx
4
Installation and putting into operation
In general all RoFry
®
units will be packed for safe transport after the final control in or-
der to reach you properly. Nevertheless we ask you to have a look at the machine on
arrival to detect any transport damages.
Note!
Visible damages have to be reported immediately!
4.1 Unwrapping
•
Open the box and remove the wrapping carefully.
•
Take out all movable parts and make sure that they are complete.
•
Remove all cartons and folio around RoFry
®
•
Pull the basket out of the unit with the black handle and remove all parts inside like operating
manual, legs, plugs etc.
4.2 Installation
•
Install the legs and put the machine on the chosen place. Take care of the follow-
ing points:
•
The RoFry
®
has to be placed on a horizontal level. Small unevenness can be cor-
rected by the adjustable legs.
•
Make sure that all ventilation holes have at least 5 cm clear space.
•
There has to be enough free space to load, unload, clean and maintain the unit.
•
The machine has to be placed in a way that the complete area around it can be
cleaned easily.
4.3 Electrical connection
Note!
While working on the unit with opened side-panels take care that the unit is dis-
connected from the mains. Even if the unit is switched off, the cooling fan may start to
run. Not paying attention may result in injury!
Please learn the electrical data of your unit from the nameplate. It is located at all types behind the
grease tray.
•
Check whether your local electrical power supply is in accordance with the data on the name
plate.
•
Make sure the supply cable is protected for units with a supply voltage as listed below:
240V (4/5-wire, min. cross-section 4
) separately with 40 Amps,
240V (4/5-wire, min. cross-section 2,5
) separately with 25 Amps
•
Protection has to be done by use of a 3 pole line circuit breaker!
•
The power supply needs to be manufactured from heat resistant, flexible cable. It is to be routed
to prevent any contact to hot parts.
•
For further information please see the wiring diagram (below)
Note!
After the unit is connected to the mains, check correct rotation direction of the
main fan: Remove the basket from the unit (pull the basket out of the unit with the
black handle, push the release and remove the basket). Switch the unit on and look
into the chamber. The fan wheel needs to rotate clockwise. If the rotation direction is
wrong, change two phases on the main terminal block (X1).
After finishing any installation work, maintenance or repair, check whether the ground
wires are connected properly to the casing and the side covers.
Содержание RoFry RF-300-CC
Страница 1: ...User Manual RoFry RF 300 330 360 CC...
Страница 2: ......
Страница 27: ...Maintenance 27 printed 07 2023 Subject to change RoFryUserManual docx 6 8 Exploded views...
Страница 28: ...28 Maintenance printed 07 2023 Subject to change RoFryUserManual docx...
Страница 31: ...Maintenance 31 printed 07 2023 Subject to change RoFryUserManual docx 6 10 Declaration of Conformity...