background image

10 

Installation and putting into operation 

printed: 07/2023  Subject to change! 

 

 RoFryUserManual.docx 

Installation and putting into operation 

In general all RoFry

®

 units will be packed for safe transport after the final control in or-

der to reach you properly. Nevertheless we ask you to have a look at the machine on 
arrival to detect any transport damages. 

Note! 

Visible damages have to be reported immediately! 

 

4.1  Unwrapping 

  Open the box and remove the wrapping carefully. 

  Take out all movable parts and make sure that they are complete. 

  Remove all cartons and folio around RoFry

®

 

  Pull  the  basket  out  of  the  unit  with  the  black  handle  and  remove  all  parts  inside  like  operating 

manual, legs, plugs etc. 

4.2  Installation 

  Install the legs and put the machine on the chosen place. Take care of the follow-

ing points: 

  The RoFry

® 

has to be placed on a horizontal level. Small unevenness can be cor-

rected by the adjustable legs. 

  Make sure that all ventilation holes have at least 5 cm clear space. 

  There has to be enough free space to load, unload, clean and maintain the unit. 

  The  machine  has  to  be  placed  in  a  way  that  the  complete  area  around  it  can  be 

cleaned easily. 

 

4.3  Electrical connection 

Note!

 While working on the unit with opened side-panels take care that the unit is dis-

connected from the mains. Even if the unit is switched off, the cooling fan may start to 
run. Not paying attention may result in injury! 

 

Please learn the electrical data of your unit from the nameplate. It is located at all types behind the 
grease tray. 

  Check  whether  your  local  electrical  power  supply  is  in  accordance  with  the  data  on  the  name 

plate. 

  Make sure the supply cable is protected for units with a supply voltage as listed below: 

 240V (4/5-wire, min. cross-section 4

) separately with 40 Amps, 

 240V (4/5-wire, min. cross-section 2,5

) separately with 25 Amps 

  Protection has to be done by use of a 3 pole line circuit breaker! 

  The power supply needs to be manufactured from heat resistant, flexible cable. It is to be routed 

to prevent any contact to hot parts. 

  For further information please see the wiring diagram (below) 

 

Note!

 After the unit is connected to the mains, check  correct rotation direction of the 

main  fan:  Remove  the  basket  from  the  unit  (pull  the  basket  out  of  the  unit  with  the 
black  handle,  push  the  release  and  remove  the  basket).  Switch  the  unit  on  and  look 
into the chamber. The fan wheel needs to rotate clockwise. If the rotation direction is 
wrong, change two phases on the main terminal block (X1). 

After finishing any installation work, maintenance or repair, check whether the ground 
wires are connected properly to the casing and the side covers. 

 

Содержание RoFry RF-300-CC

Страница 1: ...User Manual RoFry RF 300 330 360 CC...

Страница 2: ......

Страница 3: ...n 10 4 1 Unwrapping 10 4 2 Installation 10 4 3 Electrical connection 10 4 4 Tap 11 4 5 Sewage 11 4 6 Cleaner Rinsing Agent 11 4 7 Exhaust 11 4 8 Preparation of Using Starting up 11 5 Operation 12 5 1...

Страница 4: ...it who Are familiar with the fundamental regulations of work safety and accident avoiding and who have been instructed how to operate the unit Read and understood the chapter about safety and warning...

Страница 5: ...no working condition Disobeying of the references in the operating manual concerning transportation storage installa tion start up operation maintenance and assembling of the unit Unauthorized mechani...

Страница 6: ...may only work at the unit under supervision of an experienced person 2 5 4 Unit control Under no circumstances it is allowed to make changes to the source code of the soft ware Only instructed person...

Страница 7: ...nintended pushing Check all screw connections for tight fitting After finishing maintenance check all safety devices for proper functionality 2 5 9 Structural changes to the unit Do not perform any ch...

Страница 8: ...s wrong handling and levels out different amounts and temperatures 3 2 Special features compact design computer controlled self diagnostic fault finding system easy to operate with two buttons no buyi...

Страница 9: ...FryUserManual docx 3 3 3 Weight Type Net weight RF 300 330 360 CC 88 5 kg 3 3 4 Electrical details Type Version Load per Ph RF 300 330 360 CC Europe Version 400V 15 5kW 50 60Hz 3Ph with N 25 A 3 3 5 N...

Страница 10: ...t with opened side panels take care that the unit is dis connected from the mains Even if the unit is switched off the cooling fan may start to run Not paying attention may result in injury Please lea...

Страница 11: ...l UBERT recom mends a common flexible sewage hose with diameter to be fixed to the sewage connection coming with the machine 4 6 Cleaner Rinsing Agent Connect the cleaner and the rinsing agent caniste...

Страница 12: ...are closed now The temperature drops Now the computer control adjusts RoFry automatically to the amount and temperature of the food product by shortening or lengthening the total cooking time to obta...

Страница 13: ...ooking time period cooking tempera ture and cooking end time Main Switch to switch RoFry ON and OFF Basket Handle to open and close the basket for loading and unloading of food products Door Lock to o...

Страница 14: ...rograms to cook a full batch of products at a time In the user parameter section you can adjust various personal preferences such as language accesss code factory default is 1965 date time select the...

Страница 15: ...an choose between New to create a new cooking program Change to change an existing cooking program Copy to copy an existing cooking program Move to move an existing cooking program to a different loca...

Страница 16: ...the basket clockwise or counterclockwise Set a cleaning prompt 0 24h afer which a cleaning must be started 0 no prompt Select which cleaning programs are available to the operator Set the frequency l...

Страница 17: ...face clean watch out that there is always enough fresh air on the surface never contact the surface with rusty material Never use bleaching or chlorine cleaners 6 1 3 Detergents To make the cleaning f...

Страница 18: ...back to home screen 6 3 Weekly Cleaning Beside the daily cleaning the following items need some special care on a weekly basis Leave current frying program by pressing the back key Enter cleaning mod...

Страница 19: ...problem possible cause remedy food does not become crispy frying time too short temperature too low steam time too long extend processing time increase temperature shorten steam time food does not be...

Страница 20: ...20 Maintenance printed 07 2023 Subject to change RoFryUserManual docx 6 5 Wiring Diagram 6 5 1 RF 300 330 360 CC 400V 50 60Hz 3Ph with N...

Страница 21: ...move the basket and then open the door Switch off the RoFry at the main switch 2 Remove the old gasket by pulling it out and clean the notch of the seal remove grease and other residues 3 Assemble in...

Страница 22: ...RoFryUserManual docx 5 Finally check proper placement of the seal in the notch 6 Insert lamella sheet and basketholder again Close the door Remove the old basket gasket by pulling it out 7 Clean the n...

Страница 23: ...e RoFryUserManual docx 8 Put in the new seal Place the splice of the seal in the middle of the upper notch 9 Push the seal into the notch Make sure neither to stretch nor to forge the seal 10 Finally...

Страница 24: ...0 Front cover RF 300 117396 2 Seitenblende RF 300 Side cover RF 300 117397 1 R ckwand RF 300 Rear cover RF 300 117403 1 Frontblende RF 330 RF 360 Front cover RF 330 RF360 117431 1 Bedienblende RF 330...

Страница 25: ...2237 342245 342412 1 Sch tz 26A 220 240V 50 60Hz Contactor 26A 220 240V 50 60Hz 343180 1 RHK RoFry Ausf hrung 16 335 kw heating element RoFry 15 0 kw 230V 344115 1 R ndelmutter A2 DIN 467 M6 Knurled n...

Страница 26: ...IN 7603 Seal copper 380607 1 Lager Flansch mit Einsatz Hochtempe ratur Bearing for use with motor basketdrive 380104 380615 1 Flansch f r L ftermotor ROFRY Flange for fan motor 380675 2 Gleitauflage K...

Страница 27: ...Maintenance 27 printed 07 2023 Subject to change RoFryUserManual docx 6 8 Exploded views...

Страница 28: ...28 Maintenance printed 07 2023 Subject to change RoFryUserManual docx...

Страница 29: ...00 Side cover RF 300 419012 Bedienpaneel Scheibe RoFry Operator panel glass RoFry 419001 Scheibe Dekor RoFry Decor panel glass RoFry 117431 Bedienblende RF 330 Front cover RF 330 419012 Bedienpaneel S...

Страница 30: ...Canister Refill basket Part No RF 5010 Scoop Part No RF 5011 French fries portioner Part No RF 5012 French fries bag rest Part No RF 5013 Store shelf Part No RF 5015 RoFry warming basin 230V 2 0kW 50...

Страница 31: ...Maintenance 31 printed 07 2023 Subject to change RoFryUserManual docx 6 10 Declaration of Conformity...

Отзывы: