CARE AND CLEANING

Clean your air conditioner occasionally to keep it looking new. 

Be sure to unplug the unit 

before cleaning to prevent chock or fire hazards.

CAUTION

Air Filter Cleaning

The air filter should be checked at least once a
month to see if cleaning is necessary. Trapped 
particles in the filter can build up and cause an 
accumulation of frost on the cooling coils.
     Push the vent handle to the Vent Closed position 
     (where applicable).
     Open the front panel.
     Grasp the filter, pull up and out.
     Wash the filter using liquid dishwashing deter-
     gent and warm water. Rinse filter thoroughly. 
     Gently shake excess water from the filter. Be
     sure the filter is thoroughly dry before replacing.
     Or, instead of washing you may vacuum the 
      filter clean.

Note: 

Never use hot water over 40 C (104 F) to

   cl ean th e ai r fil ter. Never attempt to operate the  

unit without the air filter.

 

Cabinet Cleaning

     Be sure to unplug the air conditioner to prevent
     shock or fire hazard. The cabinet and front may
     be dusted with an oil-free cloth or washed with
     a cloth dampened in a solution of warm water
     and mild liquid dishwashing detergent. Rinse
     thoroughly and wipe dry.
     Never use harsh cleaners, wax or polish on the 
     cabinet front.
     Be sure to wring excess water from the cloth before
     wiping around the controls. Excess water in or around
     the controls may cause damage to the air conditioner.
     Plug in air conditioner.

      If you plan to store the air conditioner during the winter,
      remove it carefully from the window according to the 
      installation instructions. Cover it with plastic or return it
      to the original carton. 
     

Winter Storage

 18

Содержание MWK-15CRN1-BJ7

Страница 1: ...87795011 MWK 15CRN1 BJ7 USER MANUAL 1 866 206 0888 3 years ans warranty garantie...

Страница 2: ...for use by young children or infirm persons without supervision Young children should be supervised to ensure that they do not play with the air conditioner If the power cord is to be replaced replace...

Страница 3: ...y cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electric shock It may cause fire and electric...

Страница 4: ...deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not using the unit for a long time If water enters the unit tu...

Страница 5: ...air conditioner contains a current detection device designed to reduce the risk of fire Please refer to the section Operation of Current Device for details In the event that the power supply cord is d...

Страница 6: ...e The unit can be controlled by the unit control alone or with the remote Vibration Unit may vibrate and make noise because of poor wall or window construction or incorrect installation ELECTRONIC CON...

Страница 7: ...ction only when cooling is not desired such as for room air circulation or to exhaust stale air on some models Remember to open the vent during this function but keep it closed during cooling for maxi...

Страница 8: ...n the display This temperature will be automatically maintained anywhere between 62 F 17 C and 86 F 30 C If you want the display to read the actual room temperature see Operate on Fan Only section NOT...

Страница 9: ...e will register in 5 seconds and the system will automatically revert back to display the previous temperature setting or room temperature when the unit is on When the unit is off there is no display...

Страница 10: ...ress and hold the Up and Down Temp Timer buttons at the same time for 3 seconds Fresh Air Vent Control on some models Figure 1 VENT CLOSED Figure 2 VENT OPEN The Fresh Air Vent allows the air conditio...

Страница 11: ...es not allow the clearance required correct by adding a piece of wood as shown in FIG 2 or by removing storm window while room air conditioner is being installed 4 Check for anything that could block...

Страница 12: ...ips Screwdriver 7 16 Locking screw and Flat washer for window panels 3 4 Long Hex head Screw Safety Lock 1 2 Long screw and Locknut 3 4 Long Flat Head Bolt and Locknut Sill Angle Bracket Long hex head...

Страница 13: ...our unit may come with internal packaging This packaging must be removed prior to installing the air conditioner back into the cabinet see Fig 5 4 Pry away front from cabinet sides as shown in Fig 3 5...

Страница 14: ...rk center of window stool 2 Place cabinet in window with bottom stool angle firmly seated over window stool as shown Bring window down temporarily behind top angle to hold cabinet in place Stool Stool...

Страница 15: ...rely 1 2 Long Screws and Locknuts Locking Screw 7 Install Window Lock and Sash Seal 1 Trim sash seal to fit window width Insert into space between upper and lower sashes 2 Attach right angle safety lo...

Страница 16: ...2 WIDTH X inside model width plus twice the thickness of framing material used HEIGHT Y inside model height plus twice the thickness of framing material used Inside Frame Height 18 47 9cm or18 45 7cm...

Страница 17: ...g 1 below Level 5 16 to 3 8 3 4 plus trim thickness See Para 5 Fig 1 4 Secure bottom rail to wood frame with two large wood screws 1 2 5cm long using the two holes in the bottom of the channel resting...

Страница 18: ...rame of 2x4 as shown in the Step 2 Prepare Wall illustrations but make it double framed on either side and install between masonry wall opening and cabinet Frame must be securely anchored to masonry w...

Страница 19: ...washing you may vacuum the filter clean Note Never use hot water over 40 C 104 F to clean the air filter Never attempt to operate the unit without the air filter Cabinet Cleaning Be sure to unplug th...

Страница 20: ...rn Control ON and set to desired setting O O O O Air conditioner cooling but room is too warm ice forming on cooling coil behind decorative front Outdoor temperature below 17 C 62 F To defrost the coi...

Страница 21: ...rmal during excessively humid days Remote sensor some models Remote control not located within range Place remote control within 20 feet and at a Remote control signal obstructed Remove obstruction Ro...

Страница 22: ...FEATURES OF REMOTE CONTROL 16 ft 5m 16 ft 5m of your 21...

Страница 23: ...22...

Страница 24: ...23...

Страница 25: ...24...

Страница 26: ...25 change is...

Страница 27: ...26 LED LED LED is displayed is displayed in in...

Страница 28: ...27 LED LED LED LED LED LED LED LED LED LED...

Страница 29: ...ted to the closest service centre The product is guaranteed for 36 months if used for normal trade purposes and is valid for the original buyer only Any warranty is deemed invalid if the product has b...

Отзывы: