background image

NOTE:

If wall thickness is 8-1/2 or more, add

aluminum flashing over bottom of frame opening
to assure no water can enter area between inner
and outer wall.

Caulking
Required

Aluminum Flashing
Over Bottom Of Frame

Over
8-1/2

3

Prepare and Install Cabinet

1. Slide chassis from cabinet. Refer back to Step

one of Window Mounting.

2. Place cabinet into opening with bottom rail

resting firmly on bottom board of wooden
frame.

3. Position cabinet to achieve proper slope for

water removal. (See Fig.1 below.)

Level

5/16
to 3/8

3 4 plus trim
thickness
See Para 5

/

Fig.1

4. Secure bottom rail to wood frame with two large

wood screws 1 (2.5cm) long using the two holes
in the bottom of the channel resting on frame.
(See Fig.2).

1 Long Wood
Screw

Fig.2

Refer to Step 4 of Window Mounting for assembly
of support brackets. A wooden strip nailed to the
outside wall should be used in conjunction with
sill support angle brackets.

Wooden
Strip

Support
Bracket

5. Screw or nail cabinet wooden frame using

shims if frame is oversized, to eliminate
distortion. Remember to maintain proper
slope as described in Step 3.

6. Install chassis into cabinet by following all

steps in Step 8 of Window Mounting.

 16

Содержание MWK-15CRN1-BJ7

Страница 1: ...87795011 MWK 15CRN1 BJ7 USER MANUAL 1 866 206 0888 3 years ans warranty garantie...

Страница 2: ...for use by young children or infirm persons without supervision Young children should be supervised to ensure that they do not play with the air conditioner If the power cord is to be replaced replace...

Страница 3: ...y cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electric shock It may cause fire and electric...

Страница 4: ...deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not using the unit for a long time If water enters the unit tu...

Страница 5: ...air conditioner contains a current detection device designed to reduce the risk of fire Please refer to the section Operation of Current Device for details In the event that the power supply cord is d...

Страница 6: ...e The unit can be controlled by the unit control alone or with the remote Vibration Unit may vibrate and make noise because of poor wall or window construction or incorrect installation ELECTRONIC CON...

Страница 7: ...ction only when cooling is not desired such as for room air circulation or to exhaust stale air on some models Remember to open the vent during this function but keep it closed during cooling for maxi...

Страница 8: ...n the display This temperature will be automatically maintained anywhere between 62 F 17 C and 86 F 30 C If you want the display to read the actual room temperature see Operate on Fan Only section NOT...

Страница 9: ...e will register in 5 seconds and the system will automatically revert back to display the previous temperature setting or room temperature when the unit is on When the unit is off there is no display...

Страница 10: ...ress and hold the Up and Down Temp Timer buttons at the same time for 3 seconds Fresh Air Vent Control on some models Figure 1 VENT CLOSED Figure 2 VENT OPEN The Fresh Air Vent allows the air conditio...

Страница 11: ...es not allow the clearance required correct by adding a piece of wood as shown in FIG 2 or by removing storm window while room air conditioner is being installed 4 Check for anything that could block...

Страница 12: ...ips Screwdriver 7 16 Locking screw and Flat washer for window panels 3 4 Long Hex head Screw Safety Lock 1 2 Long screw and Locknut 3 4 Long Flat Head Bolt and Locknut Sill Angle Bracket Long hex head...

Страница 13: ...our unit may come with internal packaging This packaging must be removed prior to installing the air conditioner back into the cabinet see Fig 5 4 Pry away front from cabinet sides as shown in Fig 3 5...

Страница 14: ...rk center of window stool 2 Place cabinet in window with bottom stool angle firmly seated over window stool as shown Bring window down temporarily behind top angle to hold cabinet in place Stool Stool...

Страница 15: ...rely 1 2 Long Screws and Locknuts Locking Screw 7 Install Window Lock and Sash Seal 1 Trim sash seal to fit window width Insert into space between upper and lower sashes 2 Attach right angle safety lo...

Страница 16: ...2 WIDTH X inside model width plus twice the thickness of framing material used HEIGHT Y inside model height plus twice the thickness of framing material used Inside Frame Height 18 47 9cm or18 45 7cm...

Страница 17: ...g 1 below Level 5 16 to 3 8 3 4 plus trim thickness See Para 5 Fig 1 4 Secure bottom rail to wood frame with two large wood screws 1 2 5cm long using the two holes in the bottom of the channel resting...

Страница 18: ...rame of 2x4 as shown in the Step 2 Prepare Wall illustrations but make it double framed on either side and install between masonry wall opening and cabinet Frame must be securely anchored to masonry w...

Страница 19: ...washing you may vacuum the filter clean Note Never use hot water over 40 C 104 F to clean the air filter Never attempt to operate the unit without the air filter Cabinet Cleaning Be sure to unplug th...

Страница 20: ...rn Control ON and set to desired setting O O O O Air conditioner cooling but room is too warm ice forming on cooling coil behind decorative front Outdoor temperature below 17 C 62 F To defrost the coi...

Страница 21: ...rmal during excessively humid days Remote sensor some models Remote control not located within range Place remote control within 20 feet and at a Remote control signal obstructed Remove obstruction Ro...

Страница 22: ...FEATURES OF REMOTE CONTROL 16 ft 5m 16 ft 5m of your 21...

Страница 23: ...22...

Страница 24: ...23...

Страница 25: ...24...

Страница 26: ...25 change is...

Страница 27: ...26 LED LED LED is displayed is displayed in in...

Страница 28: ...27 LED LED LED LED LED LED LED LED LED LED...

Страница 29: ...ted to the closest service centre The product is guaranteed for 36 months if used for normal trade purposes and is valid for the original buyer only Any warranty is deemed invalid if the product has b...

Отзывы: