24
TROUBLESHOOTING
Problems
Possible Solutions
Grill will not light.
1. Push and turn the knob and check for sparks.
2. If there is a spark, check to make sure gas is supplied to the
burner.
a. Purge the line of any trapped air.
b. Check to see if you can match-light the burner.
c. Check to see that the other burners operate normally.
d. Visually check the electrode and wire while pushing the igniter
knob. If a spark occurs anywhere but the igniter tip, the igniter must
be replaced.
Burner flame is yellow and there
is a noticeable gas odour
1. Check the burner inlet for obstruction, especially for spiders
and other insects.
2. Check the air shutter for proper adjustment.
3. Check for the source of gas leaks.
Excessive flare-ups
1.
Keep hood up when grilling.
2. Keep knobs on low.
3. Turn one burner off if necessary.
4. Post heat grill for 10-15 minutes, as this will burn off drippings.
5. Use meats containing less fat.
6. Always grill chicken on low, meat side down for 20 minutes and
turn to skin side for another 20 minutes. Follow above steps.
7. If flare up continues, move meats to warming rack until flame
settles down.
8. Never spray water on gas flames
—
it will destroy your grill.
Burner blows out
1. Check for any burner defects.
2. Check for proper burner installation.
3. Make sure only a proper LP-gas tank is used.
4. Make sure the gas supply is sufficient.
5. Check if the LP tank is empty.
Low heat
The propane regulator assembly incorporates an excess flow
device designed to supply the grill with sufficient gas flow under
normal conditions, yet control excess gas flow.
Rapid changes in pressure can trigger the excess flow device,
providing a low flame and low temperature. If the tank valve is
turned open to allow gas flow while a burner valve is open, the
surge of pressure will cause the device to activate. The device will
remain closed until the pressure is equalized. This should occur
within 5 seconds.
To ensure this does not cause difficulty in lighting the grill,
follow these instructions:
1. Make sure all burner valves are
“
OFF.
”
2. Open the tank valve and wait 5 seconds.
3. Light the burner one at a time following the lighting instructions listed
in the left door and Page 24.
文件使用
"pdfFactory Pro"
试用版本创建