NOTICE
This unit allows the condensation to evaporate and flow out through the exhaust
hose automatically when the unit is in cooling mode. When the unit is in heating
mode and the water level reaches the detected level, it will begin to pump for
sixty seconds. After sixty seconds, if the water level is still on the detected level,
the unit will stop working and the "E7" warning will appear on the screen. Once
the excess water is drained, the unit will restart automatically after 3 seconds.
Please make sure that the rubber cap is locked on the drain hole,and note that
the exhaust pipe and the drain hose must be extended through the
closest window when the unit is running.
MAINTENANCE
PLEASE DISCONNECT THE POWER CORD BEFORE CARRYING OUT ANY
MAINTENANCE TASKS.
AIR FILTER
The air filter located on one side of the unit can be removed, simply by
pulling the frame in an upward motion.
CONDENSER/EVAPORATOR
To clean, use a vacuum cleaner with a brush attachment.
CABINET
Wipe with a damp cloth and dry with a soft cloth.
To remove the air filter, please follow the arrow direction and push the filter
lightly. Then take out the filter for cleaning
.