Table 7 - Installation Menu Setting
Label
Description
Values
UNIT FUNCTION
Unit functionality
Set to default mode: AI* or DG
FUNCTION LOCK
Functionality Lock
If locked, pilot may not change unit function
PITCH TRIM
Pitch trim
Trim as needed: ±20 Degrees (0*)
ROLL TRIM
Roll trim
Trim as needed: ±5 Degrees (0*)
SLIP TRIM
Slip trim
Trim as needed: ±5 Degrees (0*)
OAT TRIM
OAT probe trim
Trim as needed: ±200 (Unitless) (0*)
IAS TRIM
IAS trim
Trim as needed: ±50 KTS or MPH (0*)
ALT TRIM
Barometric altitude trim
Trim as needed: ±500 Feet
IAS UNITS
IAS display units
Knots* (KTS) or Miles Per Hour (MPH)
IAS VSO
Stalling speed in landing
configuration
Set to match limits: 40 to 300 knots (50*)
IAS VS1
Stalling speed in a specific
configuration
Set to match limits: 40 to 300 knots (60*)
IAS VFE
Maximum flap extended speed
Set to match limits: 40 to 300 knots (100*)
IAS VNO
Maximum structural cruising speed Set to match limits: 40 to 300 knots (150*)
IAS VNE
Never exceed speed
Set to match limits: 40 to 300 knots (175*)
IAS VMC
Minimum control airspeed with the
critical engine inoperative
Set to match limits: 40 to 300 knots or disabled*
IAS VYSE
Speed for best rate of climb OEI
(single engine)
Set to match limits: 40 to 300 knots or disabled*
BARO UNITS
Altimeter barometric units
Inches of Mercury* (INHG), Millibars (MB)
TEMP UNITS
OAT units
Celsius* (C) or Fahrenheit (F)
GPS NAV SRC
Serial GPS format
NONE*, AV1 9600, NMEA1 4800, NMEA1 9600,
BEACON X
SERIAL 2
Auxiliary serial input
NONE*, BEACON X, APA MINI
SERIAL 3
MFD page enable
NONE, AVLINK*
AID MODE
AHRS aiding mode
NONE
[1]
, MAG1*, MAG2
VIBE MONITOR
Vibration monitor
Push to view
GYRO CAL
Calibrates aircraft gyros
Perform at installation or software update
MAG CAL
Calibrates internal magnetometer
Perform in-flight calibration after installation
–
only available for units with magnetometer
DEMO MODE
Demo mode
DISABLED*, MODE 1, MODE 2
SW PART NUM
Software part number
For reference
SW VERSION
Software version
For reference
SW CHECKSUM
Software checksum
For reference
SW CERT
Software certification
For reference
* Initial factory value
[1]
Initial and only option for units without magnetometer