UAS CLARCOR SMOG-HOG MSH Series Скачать руководство пользователя страница 8

4

revised 03/15

SMoG-HoG

®

electronic air cleaner

AUTOMATIC PARTS WASHERS         

certain commercially available units combine and 

automate the features necessary for effective cleaning, 

including water heating, detergent injection, agitation, 

rinsing and drying. 

OTHER CLEANING CONSIDERATIONS 

the previous methods address the cleaning of unicells 

and filter media. the MSH cabinet should also be 

periodically cleaned (i.e., during normal planned 

downtimes) to reduce contaminant build up.  High 

voltage output of the power packs should also be 

checked when manual cleaning is performed. 

  5.4  APPEARANCE OF COMPONENTS 

AFTER CLEANING 

Components should have a clean, not necessarily 

“new,” aluminum appearance. Moderate discoloration 

will not affect unit efficiency. checklist for acceptable 

components. 

UNICELL 

1.  Frame, end plates and cell plates are free of 

contaminant build-up (residual contaminant has been 

removed between plates and at comer supports). 

2.  The frame is square, cell plates are parallel and cell hot 

plates are centered between ground plates. 

3.  ionizer standoff insulators and cell triangular insulators 

are cleaned (no residual coating). Cracked or carbon-

tracked insulators have been replaced.   

4.  Ionizing wires and springs are intact and taut, centered 

between plates and free of coatings. 

5.  contact springs and contact screws are properly 

located, and replace missing contact hardware.

6. contact springs are not deformed. 

7.  Bent or broken parts have been repaired or replaced. 

PRE-FILTERS/AFTER-FILTERS 

1.  aluminum media and frame are free of contaminant. 

2. frame is square and media is intact. 

3. filters are to be installed with drain holes on the bottom.

CABINET 

1. Door feed-thru insulators are cleaned and white. 

2. Door gaskets are cleaned and intact. 

3.  component tracks are free of contaminant build up  

(for unicell grounding). 

4. Module drain sump is cleaned and free-flowing. 

5. Interior is free of extreme contaminant build-up. 

6.  Blower wheel is free of contaminant build-up.  

 

  5.5   REPLACING DAMAGED IONIZER 

WIRES

1.  remove the damaged wire from each spring. also replace 

spring if it is damaged.

2.  Loop one end of the new wire over the bottom spring, then 

extend the top spring and loop the end of the wire over the top 

spring. Pliers may aid in this procedure (Refer to Figure 4).

NOTE:  In the event that replacement wires are not 

immediately available, the ionizer may be left in 

service. Remove broken wire(s) and springs from the 

assembly. Operation with missing wires will result in 

reduced operating efficiency.  

6.  TROUBLESHOOTING

  6.1  TOOLS REQUIRED

Screwdriver: 

8 inches or longer with insulated plastic handle.

Volt-Ohm meter: For checking input voltage, low-voltage DC 

and continuity (ohms).
High-voltage probe: 

for checking high-voltage power supply 

(range: 0 to 15 KVDC)
Amp probe (or clip-on amp meter): For checking motor 

current.

  6.2   PERFORM BEFORE 

TROUBLESHOOTING 

The following should be checked to the module(s) 

in which the indicator light(s) is flashing or is not 

illuminated. corrections should be completed and parts 

replaced. 

• Contact springs in the correct location, Figure 1. 

•  Unicell components have a moderate to extreme 

contaminant build up, manually clean the unicell 

components. 

•  Ionizer wires and tension springs missing or broken, 

remove broken wires and springs from the drain sump. 

•  Ionizer standoff insulators, cell triangular insulators, 

and or door feed through insulators display moderate 

to extreme contaminant build up, broken or carbon 

tracked insulators (imbedded black streak which 

cannot be removed by cleaning, replace insulator).  

 

!

  C A U T I O N

TROUBLESHOOTING AND SERVICING

ProceDureS SHouLD Be PerforMeD By

QuaLifieD PerSonneL onLy

Содержание CLARCOR SMOG-HOG MSH Series

Страница 1: ...Industrial Electrostatic Air Cleaner l SMOG HOG MSH Model OWNER S MANUAL ...

Страница 2: ...ce have the following information available when contacting UAS UAS ORDER _________________________________________________________________ UNIT MODEL ________________________________________________________________ UNIT SERIAL _________________________________________________________________ SYSTEM ACCESSORIES ______________________________________________________________________________ ________...

Страница 3: ...G 2 5 1 Normal Maintenance 2 5 2 Manual Cleaning of SMOG HOG Components 3 5 3 Manual Cleaning Methods 3 5 4 Appearance Of Components After Cleaning 4 5 5 Replacing Damaged Ionizer Wires 4 6 TROUBLESHOOTING 4 6 1 Tools Required 4 6 2 Perform Before Troubleshooting 4 6 3 Troubleshooting Procedures 5 6 4 Troubleshooting Table 8 7 REPLACEMENT PARTS 9 7 1 Replacement Parts List 9 8 FIGURES 10 12 9 WIRI...

Страница 4: ...cessive accumulation which may result in flash over or fire damage The air cleaner should not be used for support of personnel or material Operate only in a safe and serviceable condition DANGER WARNING CAUTION C A U T I O N This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and th...

Страница 5: ...en using power pack 21 1216 and 5 6mA when using power pack 21 1234 In the event of a short circuit or other overload condition the power supply is designed to cause the high voltage to collapse When the voltage collapses the indicator light will blink When the overload is removed the voltage will automatically build up to normal and the indicator light will illuminate The power supply is self pro...

Страница 6: ...ions Periodically momentary shorts will occur indicated by the flickering indicator light If the light is dim fails to glow or continues to flicker the components may need cleaning or servicing see Cleaning Instructions Section 5 2 and 5 3 5 MAINTENANCE AND MANUAL CLEANING 5 1 Normal Maintenance Once the unit is operational periodic maintenance is necessary to assure proper performance Follow a re...

Страница 7: ...mation or some other undesirable condition Time is necessary for effective cleaning Soaking may seem slower and less effective than high impingement and or hot water above 180 F for cleaning action so personnel should be forewarned about using excessive pressure or temperature to shortcut the cleaning process High pressure or stream spray cleaning until plate edges are shiny is not effective Not o...

Страница 8: ...kets are cleaned and intact 3 Component tracks are free of contaminant build up for unicell grounding 4 Module drain sump is cleaned and free flowing 5 Interior is free of extreme contaminant build up 6 Blower wheel is free of contaminant build up 5 5 REPLACING DAMAGED IONIZER WIRES 1 Remove the damaged wire from each spring Also replace spring if it is damaged 2 Loop one end of the new wire over ...

Страница 9: ...high voltage The grounding procedure statement is not identified within the troubleshooting steps but should be performed The power pack total current output is limited to a maximum of 5 milliamps to assure personnel safety A high voltage probe is required to measure high voltages to the ionizer and collector circuits to the unit As an accessory a high voltage probe can be purchased for a multimet...

Страница 10: ...ar itself by removing the unicell s from the module and then installing the unicell s back into the module Place MSH off connect all wires which have been disconnected and install unicell s b Indicator light is illuminated with the high voltage wire 7 connected to the collector cell connector on the power pack Place MSH off and connect high voltage wire 8 to the ionizer connector on the power pack...

Страница 11: ... 11 8 KVDC If the ionizer voltage is below specifications refer step 2 Ionizer Conditions Causing Failure Low ionizer voltage will decrease the collector cell voltage but low cell voltage will not affect the ionizer voltage 4 Place the tip of the high voltage probe to the collector cell door feed through insulator bolt The high voltage measurement should be 5 0 to 7 3 KVDC If the collector cell vo...

Страница 12: ...fective Unicell dirty Unicell malfunction Unicell installed backwards or upside down High voltage contacts dirty Loss of input voltage Unicell malfunctioning Power supply defective POSSIBLE SOLUTIONS Replace lamp Check connection to lamp Check power supply Replace air mover Clean foreign object from air mover Replace control switch Check connection at control switch Correct wiring Engage safety in...

Страница 13: ...r 33Ͳ10116 33Ͳ10121 2 Unicell 02Ͳ10429Ͳ0001ͲS 02Ͳ1921ͲS 3 Mesh AfterͲFilter 33Ͳ10110 33Ͳ10120 4 Inlet Cone Ring 32Ͳ10053 32Ͳ10067 5 Motorized Impeller Fan 32Ͳ10052 32Ͳ10065 6 Ionizer Spring 36Ͳ0068 36Ͳ0068 7 Cell Spring 36Ͳ0012 36Ͳ0012 8 Cell Ground Spring 36Ͳ0016 36Ͳ0016 9 Interlock Switch 20Ͳ0005 20Ͳ0005 10 Filter Door Latch 39Ͳ10055 39Ͳ10055 11 Feed Through Insulator 37Ͳ0026 37Ͳ0026 12a Power P...

Страница 14: ...10 Revised 03 15 SMOG HOG Electronic Air Cleaner Figure 1 Unit Components ...

Страница 15: ...1 Revised 03 15 SMOG HOG Electronic Air Cleaner Figure 2 Drain Loop Assembly Figure 4 Replacing Ionizer Section Figure 3 Ionizer and Cell Voltage Measurement Figure 5 Grounding The Collector Cell Section ...

Страница 16: ...12 Revised 03 15 SMOG HOG Electronic Air Cleaner Figure 6 Grounding the Ionizing Section Figure 7 Power Pack Input Output Connections ...

Страница 17: ...13 Revised 03 15 SMOG HOG Electronic Air Cleaner MSH 05 ...

Страница 18: ...14 Revised 03 15 SMOG HOG Electronic Air Cleaner MSH 05 M ...

Страница 19: ...15 Revised 03 15 SMOG HOG Electronic Air Cleaner MSH 11 ...

Страница 20: ...16 Revised 03 15 SMOG HOG Electronic Air Cleaner MSH 11 M ...

Страница 21: ...17 Revised 03 15 SMOG HOG Electronic Air Cleaner MSH 11 w Optional ON OFF Switch ...

Страница 22: ...18 Revised 03 15 SMOG HOG Electronic Air Cleaner MSH 05 1PH Interconnect MSH 11 1PH Interconnect ...

Страница 23: ...19 Revised 03 15 SMOG HOG Electronic Air Cleaner MSH 05 3PH Interconnect MSH 11 3PH Interconnect ...

Страница 24: ...dified except by a written instrument signed by the President or Vice President of Sales of UAS THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN ORALOR IMPLIED INCLUDINGANYIMPLIED WARRANTYOF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NONINFRINGEMENT As Purchaser s exclusive remedy for any defects in the equipment UAS will exchange or repair any defective part...

Отзывы: